Schneider Electric Gulf Countries and Pakistan Website

Welcome to our website.

Choose another country or region

View all   Uniflair InRow Cooling Accessories
ACAC20002 Product picture Schneider Electric

ACAC20002

ACAC20002 Product picture Schneider Electric
ACAC20002

CDU Flexible Fluid Piping - 300 Feet (91.4 Meters)

Show more characteristics
The maximum number of products that can be compared is 4

  • Overview
    Model Name
    CDU Flexible Fluid Piping - 300 Feet (91.4 Meters)
    Includes
    Installation guide
    Standard Lead Time
    Usually Ships within 4 Weeks
    Product Distribution
    Afghanistan , Albania , Algeria , Andorra , Angola , Anguilla , Antigua And Barbuda , Argentina , Armenia , Aruba , Australia , Austria , Azerbaijan , Bahamas , Bahrain , Bangladesh , Barbados , Belarus , Belgium , Belize , Benin , Bermuda , Bhutan , Bolivia , Bosnia And Herzegovina , Botswana , Brazil , Brunei Darussalam , Bulgaria , Burkina Faso , Burundi , Cameroon , Canada , Cayman Islands , Central African Republic , Chad , Chile , China , Colombia , Congo , CONGO, THE DEMOCRATIC REPUBLIC OF THE , Cook Islands , Costa Rica , Cote D'Ivoire , Croatia , Cuba , Cyprus , Czech Republic , Denmark , Djibouti , Dominica , Dominican Republic , East Timor , Ecuador , Egypt , El Salvador , Equatorial Guinea , Eritrea , Estonia , Ethiopia , Falkland Islands (Malvinas) , Fiji , Finland , France , Gabon , Gambia , Georgia , Germany , Ghana , Gibraltar , Greece , Grenada , Guadeloupe , Guatemala , Guinea , Guyana , French Guiana , Haiti , Honduras , Hong Kong , Hungary , Iceland , India , Indonesia , Iran (Islamic Republic Of) , Iraq , Ireland , Israel , Italy , Jamaica , Japan , Jordan , Kazakhstan , Kenya , KOREA, REPUBLIC OF , Kuwait , Latvia , Lebanon , Lesotho , Liberia , Liechtenstein , Lithuania , Luxembourg , Macedonia , Madagascar , Malawi , Malaysia , Mali , Malta , Martinique , Mauritania , Mauritius , Mayotte , Mexico , Moldova, Republic Of , Mongolia , Morocco , Mozambique , Myanmar , Namibia , Nepal , Netherlands , Netherlands Antilles , New Zealand , Nicaragua , Niger , Nigeria , Norway , Oman , Pakistan , Panama , Papua New Guinea , Paraguay , Peru , Philippines , Poland , Portugal , Puerto Rico , Reunion , Romania , Russian Federation , Rwanda , SAINT KITTS AND NEVIS , SAINT LUCIA , SAINT VINCENT AND THE GRENADINES , Saudi Arabia , Senegal , Sierra Leone , Singapore , Slovakia (Slovak Republic) , Slovenia , Somalia , South Africa , Spain , Sri Lanka , Sudan , Suriname , Sweden , Switzerland , Taiwan , Tajikistan , TANZANIA, UNITED REPUBLIC OF , Thailand , Togo , Trinidad And Tobago , Tunisia , Turkey , Turkmenistan , Turks And Caicos Islands , Uganda , Ukraine , United Arab Emirates , United States , Uruguay , Uzbekistan , Venezuela , Viet Nam , VIRGIN ISLANDS (UNITED STATES) , Western Sahara , Yemen , Zambia , Zimbabwe
    General
    Maximum Recommended Flow Rate
    18.5
    Piping Material
    PEX-AL-PEX
    Pressure Rating
    150.0
    Piping Connections
    Unterminated
    Minimum Bend Radius
    8.0
    Minimum Fluid Temperature
    42.0
    Maximum Fluid Temperature
    60.0
    Pressure Drop per foot (0.305m)
    0.13
    Physical
    Maximum Height
    279.0 mm
    Maximum Width
    1067.0 mm
    Maximum Depth
    1067.0 mm
    Net Length
    300.0
    Net Weight
    37.73 kg
    Shipping Weight
    39.55 kg
    Shipping Height
    318.0 mm
    Shipping Width
    1156.0 mm
    Shipping Depth
    1156.0 mm
    Color
    White
    Units per Pallet
    6.0
    Conformance
    Standard warranty
    1 year (parts only)
  • View more View less

    Documents

    Language
    • English4
    User guide
    Format
    Size
    Date
    Add to My Documents
    Cooling Distribution Unit (Version V1)
    Files in document
    Description
    Installation; Commissioning; Installation; Commissioning
    prp.document.label.format zip
    Size 6.6 MB
    Date 2/27/15
    Files in document
    Description
    Installation; Commissioning; Installation; Commissioning
    CAD
    Format
    Size
    Date
    Add to My Documents
    ACFD12-B - Cooling Distribution Unit, Bottom Distribution Piping (Version V0)
    Files in document
    Description
    Cooling Solutions, Close Coupled Air Conditioners, InRow Chilled Water, Package
    prp.document.label.format zip
    Size 4.4 MB
    Date 3/21/12
    Files in document
    Description
    Cooling Solutions, Close Coupled Air Conditioners, InRow Chilled Water, Package
    ACFD12-T - Cooling Distribution Unit, Top Distribution Piping (Version V0)
    Files in document
    Description
    Cooling Solutions, Close Coupled Air Conditioners, InRow Chilled Water, Package
    prp.document.label.format zip
    Size 4.9 MB
    Date 3/21/12
    Files in document
    Description
    Cooling Solutions, Close Coupled Air Conditioners, InRow Chilled Water, Package
    Specification guide
    Format
    Size
    Date
    Add to My Documents
    prp.document.label.format pdf
    Size 509.5 KB
    Date 8/1/14
    Description
    Technical Data
  • Technical FAQs

    No results found
    Unfortunately, related FAQs are unavailable due to temporary technical issues. Please try again later.
Compare products: /