Gulf countries and Pakistan
Schneider Electric Gulf Countries and Pakistan Website

Welcome to our website.

You can choose another country to view available products or go to our Global website for company information.

Choose another country or region
View all Galaxy 5500
G55TUPSM60HS Product picture Schneider Electric

G55TUPSM60HS

G55TUPSM60HS Product picture Schneider Electric
G55TUPSM60HS

MGE Galaxy 5500 60kVA 400V Integrated Parallel UPS, Start-up 5x8

Show more characteristics >
Add to My Products Remove from My Products
The maximum number of products that can be compared is 4

  • Overview
    Description
    A versatile 3-phase UPS for facility, industrial and data center applications. Configurable system with a comprehensive range of accessories to meet your application demands.
    Model Name
    MGE Galaxy 5500 60kVA 400V Integrated Parallel UPS, Start-up 5x8
    Includes
    Installation guide , Network Management Card , Start-Up Service , User Manual
    Standard Lead Time
    Usually Ships within 2 Weeks
    Product Distribution
    Albania , Algeria , Andorra , Angola , Anguilla , Antigua And Barbuda , Argentina , Armenia , Aruba , Austria , Azerbaijan , Bahamas , Bahrain , Barbados , Belarus , Belgium , Belize , Benin , Bermuda , Bolivia , Bosnia And Herzegovina , Botswana , Brazil , Bulgaria , Burkina Faso , Burundi , Cameroon , Cayman Islands , Central African Republic , Chad , Chile , China , Congo , CONGO, THE DEMOCRATIC REPUBLIC OF THE , Costa Rica , Cote D'Ivoire , Croatia , Cuba , Cyprus , Czech Republic , Denmark , Djibouti , Dominica , Dominican Republic , Ecuador , Egypt , El Salvador , Equatorial Guinea , Eritrea , Estonia , Ethiopia , Falkland Islands (Malvinas) , Finland , France , Gabon , Gambia , Georgia , Germany , Ghana , Gibraltar , Greece , Grenada , Guadeloupe , Guatemala , Guinea , Guyana , French Guiana , Haiti , Honduras , Hong Kong , Hungary , Iceland , Iran (Islamic Republic Of) , Iraq , Ireland , Israel , Italy , Jamaica , Jordan , Kazakhstan , Kenya , Kuwait , Latvia , Lebanon , Lesotho , Liberia , Liechtenstein , Lithuania , Luxembourg , Macedonia , Madagascar , Malawi , Mali , Malta , Martinique , Mauritania , Mauritius , Mayotte , Moldova, Republic Of , Mongolia , Morocco , Mozambique , Namibia , Netherlands , Netherlands Antilles , Nicaragua , Niger , Nigeria , Norway , Oman , Pakistan , Panama , Paraguay , Peru , Poland , Portugal , Puerto Rico , Reunion , Romania , Russian Federation , Rwanda , SAINT KITTS AND NEVIS , SAINT LUCIA , SAINT VINCENT AND THE GRENADINES , Saudi Arabia , Senegal , Sierra Leone , Slovakia (Slovak Republic) , Slovenia , Somalia , South Africa , Spain , Sudan , Suriname , Sweden , Switzerland , Taiwan , Tajikistan , TANZANIA, UNITED REPUBLIC OF , Togo , Trinidad And Tobago , Tunisia , Turkey , Turkmenistan , Turks And Caicos Islands , Uganda , Ukraine , United Arab Emirates , Uruguay , Uzbekistan , Venezuela , VIRGIN ISLANDS (UNITED STATES) , Western Sahara , Yemen , Zambia , Zimbabwe
    General
    Bypass Voltage Tolerance
    +/-10% settable from +/-4/6/8 and 10%
    Max Bypass Input Current
    87 A
    Output
    Output Power Capacity
    54.0 KW / 60.0 kVA
    Max Configurable Power (Watts)
    54.0 KW / 60.0 kVA
    Nominal Output Voltage
    400 3PH
    Output Voltage Note
    Configurable for 380 : 400 or 415 V 3 Phase nominal output voltage
    Output Voltage Distortion
    Less than 2%
    Output Frequency (sync to mains)
    50/60 Hz +/- 3 Hz user adjustable +/- 0.1
    Other Output Voltages
    380, 415V
    Crest Factor
    3 : 1
    Double Conversion Online
    Waveform Type
    Sine wave
    Output Connections
    (1) Hard Wire 4-wire (3PH + G) (Battery Backup) , (1) Hard Wire 4-wire (3PH + N) (Battery Backup)
    Output Voltage Tolerance
    +/- 2% static and 100% load step
    Output Voltage THD
    < 1% linear load and < 2.5% nonlinear load
    Overload Operation
    10 minutes @ 125% and 60 seconds @ 150%
    Required Output Current Protection
    63 A
    Neutral Output Current
    87 A
    Bypass
    Built-in Maintenance Bypass , Built-in Static Bypass , Optional External Bypass
    Input
    Nominal Input Voltage
    400 3PH
    Input Frequency
    45 - 65 Hz
    Input Connections
    Hard Wire 4-wire (3PH + G) , Hard Wire 4-wire (3PH + N)
    Input voltage range for main operations
    323 - 437 (380V) V , 340 - 460 (400V) V , 353 - 477 (415V) V
    Input voltage adjustable range for mains operation
    250 - 470V
    Other Input Voltages
    380 , 415
    Maximum Input Current
    88 A
    Input Breaker Capacity
    125 A
    Maximum Short Circuit Withstand (Icw)
    20.0
    Input Total Harmonic Distortion
    Less than 3% for full load
    Type of Input Protection Required
    3-pole breaker
    Batteries & Runtime
    Battery Type
    No internal battery - uses external battery system
    Typical recharge time
    10 hour(s)
    Replacement battery cartridge note
    Battery runtimes are estimates only.
    Nominal Battery Voltage
    432V
    End of Discharge Battery Voltage
    +/-154 V
    Overload Operation
    60 seconds @ 120% and 30 seconds @ 145%
    Communications & Management
    Available SmartSlot™ Interface Quantity
    2
    Pre-Installed SmartSlot™ Cards
    AP9635
    Control panel
    Multi-function LCD status and control console
    Emergency Power Off (EPO)
    Yes
    Physical
    Maximum Height
    1900.0 mm
    Maximum Width
    712.0 mm
    Maximum Depth
    850.0 mm
    Net Weight
    400.0 kg
    Shipping Weight
    420.0 kg
    Shipping Height
    2030.0 mm
    Shipping Width
    980.0 mm
    Shipping Depth
    960.0 mm
    Environmental
    Operating Environment
    0 - 40 °C
    Operating Relative Humidity
    0 - 95 %
    Operating Elevation
    0-999.9 meters
    Storage Temperature
    -20 - 45 °C
    Storage Relative Humidity
    0 - 95 %
    Storage Elevation
    0-12000 meters
    Audible noise at 1 meter from surface of unit
    55.500 dB
    Online Thermal Dissipation
    14539.000 BTU/hr
    Conformance
    Approvals
    CE , EN/IEC 62040-3 , IEC 62040-1-2 , IEC 62040-2 , ISO 9001 , TUV , VDE
    Standard warranty
    1 year (parts only) , 1 year on-site repair or replace with factory authorized Start-Up
    Sustainable Offer Status
    Battery Directive
    Compliant
  • Documents and Downloads

    Language
    • English
    Catalogue
    Date
    Size
    Add to My Documents
    Galaxy 5500 Technical Brochure (Version 2)
    Date 12/11/18
    Size 989.7 KB
    User guide
    Date
    Size
    Add to My Documents
    Modbus Register Map for TCP IP- MGE Galaxy 5500 (Version 0)
    Galaxy 5000/5500 40-130 kVA 480 V and 20-120 kVA 400 V Operation Manual (Version 0)
    Schneider Electric Important Safety Instructions (Version 0)
    Galaxy 5000 and Galaxy 5500 Modbus Register Map (Version 0)
    Galaxy 5500 20 - 120 kVA 400 V Installation (Version 3)
    Galaxy 5500 20 - 120 kVA 400 V receiving and unpacking (Version 2)
    MGE Galaxy 5500 20-120 kVA 400 V Safety and Handling (Version 0)
    CAD
    Date
    Size
    Add to My Documents
    G55T30K120HOTR2-SD – MGE Galaxy 5500 30-120kVA UPS 2MOD(N+1) with Output Transformer System One Line (Version 0)
    G55T30K120HR2-SD – MGE Galaxy 5500 30-120kVA UPS 2MOD(N+1) System One Line (Version 0)
    G55T30K120HR2-WD – MGE Galaxy 5500 30-120kVA UPS 2MOD(N+1) Wiring Diagram (Version 0)
    G55TTC60RH - MGE Galaxy 5500 60kVA Transformer Stand alone Cabinet (Version 0)
    G55TUPSM20K120H - MGE Galaxy 5500 Integrated Parallel UPS 20-120kVA without Internal Batteries (Version 2)
    Specification guide
    Date
    Size
    Add to My Documents
    MGE Galaxy 5500 20-120 kVA 400 V Technical Specifications (Version 2)
    Certificate
    Date
    Size
    Add to My Documents
    CE Declaration of Conformity MGE Galaxy 5500 20-120kVA UPS and AUX (Version 0)
    MGE Galaxy 5500 - CB-TUV certificate (Version 0)
    Galaxy 5500 EU Declaration of Conformity (Version 1)
    Marine certificate
    Date
    Size
    Add to My Documents
    DNV-GL Marine Certificate Galaxy 5500 UPS 3ph (Version 1.0)
    Specification for tender
    Date
    Size
    Add to My Documents
    CSI 2004/1995 MGE Galaxy 5500 400 V Single System (Version 0)
    CSI 2004/1995 MGE Galaxy 5500 400 V Parallel System (Version 1)
  • Technical FAQs

    No results found
    Unfortunately, related FAQs are unavailable due to temporary technical issues. Please try again later.
Compare products: /