Australia
Welcome to the Schneider Electric Website

Welcome to our website.

You can choose another country to view available products or go to our Global website for company information.

Choose another country or region

 

Acti 9 iID

DIN Rail Residual current circuit breakers (RCCB) up to 100 A

Incoordination with Acti 9 and Multi 9 MCBs, this RCCB will also give you additional protection against any direct contact

Acti 9 iID
  • Features

    Achieve full coordination with Acti 9 and Multi 9 MCBs with DIN rail RCCB you can rely on. Providing better continuity of service as well as offering a complete environmentally friendly option, the DIN rail RCCB will also give you additional protection against any direct contact.
    • Complete with VISI-SAFE, which helps to ensure the ultimate in safety for both operation and maintenance work.
    • Class-2 insulation: ensures continuous safety for both operators and unqualified personnel.
    • Complete with VisiTrip: detects faulty outgoers quickly and reduces intervention time.
    • Fully immune earth leakage protection: provides better continuity of service, especially with the new SI type (Super immune) which has been designed with polluted environments and networks in mind.
    • The optional electrical auxiliaries and mounting accessories are consistent with those offered on Acti 9 iC60 miniature circuit breakers (MCBs).
    • Nominal current: 1 to 100 A.
    • SI (Super immune), AC, A.
    • 30 mA sensitivity: provides additional protection against direct contact (in accordance with IEC 60364).
    • 100 mA, 300 mA, 500 mA sensitivities: provide additional protection against fire and indirect contact (in accordance with IEC 60364).
    • Selective version: ensures correct discrimination between different residual current circuit breakers as well as the tripping of the device closest to the fault.
    • Coordination with Acti 9 and Multi 9 MCBs.
    • Fully compliant with standard IEC EN 61008-1.
    • Certified by national official authorities.
    • Ideally suited to isolation in full accordance with industrial standard IEC/EN 60947-2.
    • Operating voltage: up to 400 V AC.
    • Insulation voltage: 500 V.
    • Optional auxiliaries available: indication of state and tripping, shunt tripping, undervoltage tripping, overvoltage tripping.


    Benefits

    Complete with VisiTrip and Visi-SAFE, the DIN rail RCCB provide greater continuity of service as well as enhanced safety to both industrial and commercial buildings.
    • Greater continuity of service with VisiTrip.
    • Greater electrical immunity with SI type (Super immune).
    • Easy-to-understand part numbers make choosing options simple and straightforward.
    • Easy to install with quick, ergonomic and safe IP20B terminal shutters.
    • Fully robust connections which provide twice the standard tightening torque.
    • Environmentally friendly: made from 100% recyclable and recoverable materials.

    Applications

    • Designed for industrial and commercial buildings
    • Prevent electrocution (in accordance with installation standard IEC 60364 and national standards).
    • Reduce fire hazards by cutting down current leakage into building electrical installations.

    Gallery

    • iID DIN rail residual current circuit-breaker, “Si” super immune
    • iID DIN rail residual current circuit-breaker. VISI-TRIP fault indicator
Nos conseillers sont disponibles pour répondre à vos questions de 8h00 à 18h00 du lundi au vendredi toute l'année.