Welcome to the Schneider Electric Website

Welcome to our website.

Select your location

Welcome the the Schneider Electric French website. It looks like you are located in the United States, would you like to change your location?

Traduisez en francais
View all   Kaedra, Mini Kaedra
13981 Product picture
Discontinued

13981

Green premium brand logo
13981 Product picture
Discontinued
13981
Green premium brand logo

Kaedra - for modular device - 1 x 12 modules - 1+1 terminal blocks

Show more characteristics
13981  has not been replaced. Please contact your customer care centre for more information.
The maximum number of products that can be compared is 4. Remove already added products.

  • Main
    range
    Kaedra
    product or component type
    Weatherproof enclosure
    enclosure type
    Enclosure for modular device
    accessories included with enclosure
    1 marking kit
    1 terminal block support
    1 wiring strap
    1 terminal block 8 holes
    1 terminal block 4 holes
    mounting plate description
    Slotted
    Complementary
    enclosure mounting
    Surface
    number of 18 mm modules per row
    12
    total number of 18 mm modules
    12
    number of horizontal rows
    1
    electrical insulation class
    Double insulation
    Class II
    provided equipment
    1 marking kit
    1 wiring strap
    1 terminal block 4 holes
    1 terminal block 8 holes
    1 terminal block support
    type of front cover
    Reversible
    Transparent
    power dissipation in W
    24 W
    [In] rated current
    63 A
    type of rail
    DIN
    number of pre-cutouts PG ISO
    17
    number of terminal blocks
    1 with 4 outgoers
    1 with 8 outgoers
    distribution block outgoers
    6 x 10 mm²
    6 x 16 mm²
    locking options description
    Optional keylock
    enclosure material
    Self-extinguishing polymer
    width
    340 mm
    height
    280 mm
    depth
    160 mm
    internal depth
    88 mm
    colour
    Door: transparent green
    Enclosure: light grey (RAL 7035)
    targeted country
    Spain
    Environment
    standards
    IEC 670
    IEC 60529
    EN 50102
    EN 50262
    IEC 60439-3
    IEC 60695-2-1
    fire resistance
    650 °C conforming to IEC 60695-2-1
    IP degree of protection
    IP65 conforming to IEC 60529
    IK degree of protection
    IK09 conforming to EN 50102
    Environmental characteristics (UV)
    UV resistant: class 3 conforming to ISO 4582:2010
    Ultraviolet degradation test conforming to ISO 4892-2:2013
    overvoltage category
    II
    ambient air temperature for operation
    -25…60 °C
    Packing Units
    Unit Type of Package 1
    PCE
    Number of Units in Package 1
    1
    Package 1 Weight
    2.025 kg
    Package 1 Height
    17 cm
    Package 1 width
    29.5 cm
    Package 1 Length
    36 cm
    Offer Sustainability
    Sustainable offer status
    Green Premium product
    REACh Regulation
    REACh free of SVHC
    Yes
    EU RoHS Directive
    Pro-active compliance (Product out of EU RoHS legal scope)
    EU RoHS Declaration
    Toxic heavy metal free
    Yes
    Mercury free
    Yes
    RoHS exemption information
    China RoHS Regulation
    China RoHS declaration
     Pro-active China RoHS declaration (out of China RoHS legal scope)
    Environmental Disclosure
    Halogen content performance
    Halogen free product
    Contractual warranty
    Warranty
    18 months
  • View more
    View less

    Documents

    Language
    • English9
    Catalogue
    Format
    Size
    Date
    Add to My Documents
    prp.document.label.format zip
    Size 80.5 MB
    Date 18/06/19
    Files in document
    pdf
    16.1 MB
    Instruction sheet
    Format
    Size
    Date
    Add to My Documents
    prp.document.label.format zip
    Size 8.8 MB
    Date 25/02/09
    Files in document
    pdf
    6.7 MB
    pdf
    2.2 MB
    Description
    Enclosure
    CAD
    Format
    Size
    Date
    Add to My Documents
    Enclosure for modular switchgear 1 row 12 modules (Version 1.0)
    Files in document
    dwg
    67.2 KB
    dxf
    175.1 KB
    dwf
    10.5 KB
    wmf
    35.4 KB
    prp.document.label.format zip
    Size 288.3 KB
    Date 2/02/05
    Files in document
    dwg
    67.2 KB
    dxf
    175.1 KB
    dwf
    10.5 KB
    wmf
    35.4 KB
    Enclosure for modular switchgear 1 row 12 modules (Version 1.0)
    Files in document
    dwg
    17.5 KB
    dxf
    40.6 KB
    dwf
    3 KB
    wmf
    12.7 KB
    prp.document.label.format zip
    Size 73.8 KB
    Date 2/02/05
    Files in document
    dwg
    17.5 KB
    dxf
    40.6 KB
    dwf
    3 KB
    wmf
    12.7 KB
    China RoHS declaration
    Format
    Size
    Date
    Add to My Documents
    13981 : Kaedra - for modular device - 1 x 12 modules - 1+1 terminal blocks
    Description
    Kaedra - for modular device - 1 x 12 modules - 1+1 terminal blocks
    prp.document.label.format pdf
    Size 195.3 KB
    Date 30/11/20
    Description
    Kaedra - for modular device - 1 x 12 modules - 1+1 terminal blocks
    End of Life Information
    Format
    Size
    Date
    Add to My Documents
    prp.document.label.format pdf
    Size 260.5 KB
    Date 10/01/12
    EU RoHS Declaration
    Format
    Size
    Date
    Add to My Documents
    13981 : Kaedra - for modular device - 1 x 12 modules - 1+1 terminal blocks
    Description
    Kaedra - for modular device - 1 x 12 modules - 1+1 terminal blocks
    prp.document.label.format pdf
    Size 195.3 KB
    Date 30/11/20
    Description
    Kaedra - for modular device - 1 x 12 modules - 1+1 terminal blocks
    Product Environmental Profile
    Format
    Size
    Date
    Add to My Documents
    prp.document.label.format pdf
    Size 322 KB
    Date 7/09/20
    Description
    None
    REACh Declaration
    Format
    Size
    Date
    Add to My Documents
    13981 : Kaedra - for modular device - 1 x 12 modules - 1+1 terminal blocks
    Description
    Kaedra - for modular device - 1 x 12 modules - 1+1 terminal blocks
    prp.document.label.format pdf
    Size 195.3 KB
    Date 30/11/20
    Description
    Kaedra - for modular device - 1 x 12 modules - 1+1 terminal blocks
  • Technical FAQs

    No results found.
    Unfortunately, related FAQs are unavailable due to temporary technical issues. Please try again later.