Welcome to the Schneider Electric Website

Welcome to our website.

Select your location

View all   Galaxy 300
G3HT30K3ILS Product picture

G3HT30K3ILS

G3HT30K3ILS Product picture
G3HT30K3ILS

MGE Galaxy 300 30kVA 400V 3:1 with Long Backup Charger, Start-up 5x8

Show more characteristics
The maximum number of products that can be compared is 4

  • Overview
    Description
    Effective three phase power protection against downtime and data loss for mission critical applications. UPS with long backup charger, supplied without batteries. To be used with external batteries. Please click here for additional runtime information.
    Model Name
    MGE Galaxy 300 30kVA 400V 3:1 with Long Backup Charger, Start-up 5x8
    Includes
    CD with software , Installation guide , Network Management Card , Start-Up Service , User Manual
    Standard Lead Time
    Usually Ships within 2 Weeks
    Product Distribution
    Afghanistan , Albania , Algeria , Andorra , Angola , Argentina , Armenia , Australia , Austria , Azerbaijan , Bahrain , Belarus , Belgium , Benin , Bhutan , Bolivia , Bosnia And Herzegovina , Botswana , Brunei Darussalam , Bulgaria , Burkina Faso , Burundi , Cambodia , Cameroon , Central African Republic , Chad , Chile , China , Congo , CONGO, THE DEMOCRATIC REPUBLIC OF THE , Cook Islands , Cote D'Ivoire , Croatia , Cyprus , Czech Republic , Denmark , Djibouti , East Timor , Egypt , Equatorial Guinea , Eritrea , Estonia , Ethiopia , Fiji , Finland , France , Gabon , Gambia , Georgia , Germany , Ghana , Gibraltar , Greece , Guadeloupe , Guinea , French Guiana , Hong Kong , Hungary , Iceland , Indonesia , Iran (Islamic Republic Of) , Iraq , Ireland , Israel , Italy , Jamaica , Jordan , Kazakhstan , Kenya , Kuwait , Latvia , Lebanon , Lesotho , Liberia , Liechtenstein , Lithuania , Luxembourg , Macedonia , Madagascar , Malawi , Malaysia , Mali , Malta , Martinique , Mauritania , Mauritius , Mayotte , Moldova, Republic Of , Mongolia , Morocco , Mozambique , Myanmar , Namibia , Nepal , Netherlands , New Zealand , Niger , Nigeria , Norway , Oman , Pakistan , Papua New Guinea , Paraguay , Peru , Philippines , Poland , Portugal , Reunion , Romania , Russian Federation , Rwanda , Saudi Arabia , Senegal , Sierra Leone , Singapore , Slovakia (Slovak Republic) , Slovenia , Somalia , South Africa , Spain , Sudan , Suriname , Sweden , Taiwan , Tajikistan , TANZANIA, UNITED REPUBLIC OF , Thailand , Togo , Tunisia , Turkey , Turkmenistan , Turks And Caicos Islands , Uganda , Ukraine , United Arab Emirates , Uruguay , Uzbekistan , Viet Nam , Western Sahara , Yemen , Zambia , Zimbabwe
    Output
    Output Power Capacity
    24.0 KW / 30.0 kVA
    Max Configurable Power (Watts)
    24.0 KW / 30.0 kVA
    Nominal Output Voltage
    230V
    Output Voltage Note
    Configurable for 380 : 400 or 415 V 3 Phase nominal output voltage
    Output Voltage Distortion
    Less than 5%
    Output Frequency (sync to mains)
    50/60 Hz +/- 5%
    Other Output Voltages
    220, 240V
    Crest Factor
    2.5 : 1
    Double Conversion Online
    Waveform Type
    Sine wave
    Output Connections
    (1) Hard Wire 3-wire (H N + G) (Battery Backup)
    Output Voltage Tolerance
    +/- 2% static and 100% load step
    Output Voltage THD
    < 3% linear load and <5% non-linear load
    Overload Operation
    60 seconds @ 120% and 30 seconds @ 145%
    Required Output Current Protection
    250 A
    Bypass
    Built-in Maintenance Bypass
    Input
    Nominal Input Voltage
    400 3PH
    Input Frequency
    45 - 65 Hz
    Input Connections
    Hard Wire 5-wire (3PH + N + G)
    Input voltage range for main operations
    340 - 477 V
    Input voltage adjustable range for mains operation
    323 - 437 (380V)V , 340 - 460 (400V)V , 357 - 477 (415V)V
    Other Input Voltages
    380 , 415
    Maximum Input Current
    48 A
    Input Breaker Capacity
    63 A
    Input Total Harmonic Distortion
    Less than 5% for full load
    Type of Input Protection Required
    gL fuse
    Batteries & Runtime
    Battery Type
    No internal battery - uses external battery system
    Communications & Management
    Pre-Installed SmartSlot™ Cards
    AP9630
    Control panel
    Multi-function LCD status and control console
    Emergency Power Off (EPO)
    Yes
    Physical
    Maximum Height
    1300.0 mm
    Maximum Width
    500.0 mm
    Maximum Depth
    950.0 mm
    Net Weight
    205.0 kg
    Shipping Weight
    231.0 kg
    Shipping Height
    1440.0 mm
    Shipping Width
    800.0 mm
    Shipping Depth
    965.0 mm
    Environmental
    Operating Environment
    0 - 35 °C
    Operating Relative Humidity
    0 - 95 %
    Operating Elevation
    0-3000 meters
    Storage Temperature
    -10 - 60 °C
    Storage Relative Humidity
    0 - 95 %
    Storage Elevation
    0-9000 meters
    Audible noise at 1 meter from surface of unit
    53.600 dB
    Online Thermal Dissipation
    1876.000 BTU/hr
    Protection Class
    IP 20
    Conformance
    Approvals
    CE , EN/IEC 62040-1-1 , EN/IEC 62040-2 , EN/IEC 62040-3 , IEC 61000-4-5 , IEC 62040-2 , TUV , VFI-SS-111
    Standard warranty
    1 year on-site repair or replace with factory authorized Start-Up
    Sustainable Offer Status
    RoHS
    Compliant
    Battery Directive
    Compliant
  • View more View less

    Documents

    Language
    • English24
    User guide
    Format
    Size
    Date
    Add to My Documents
    Galaxy 300/300i 10-40 kVA Receiving&Unpacking 380/400/415 V (Version V2)
    Description
    Providing information on storage conditions and how to unpack the galaxy 300 and 300i cabinets and remove them from the pallet
    prp.document.label.format pdf
    Size 5.1 MB
    Date 18/07/16
    Description
    Providing information on storage conditions and how to unpack the galaxy 300 and 300i cabinets and remove them from the pallet
    Galaxy 300 & Galaxy 300i 10-40 kVA Operation 380/400/415 V (Version V2)
    Description
    Providing the user with information on operation, maintenance and troubleshooting of the Galaxy 300 and 300i system
    prp.document.label.format pdf
    Size 5.9 MB
    Date 18/07/16
    Description
    Providing the user with information on operation, maintenance and troubleshooting of the Galaxy 300 and 300i system
    Galaxy 300 10-40 kVA 3:1 and 3:3 Installation Manual (Version V1)
    Description
    Providing the certified electrician with information on how to install and connect the Galaxy 300 UPS
    prp.document.label.format pdf
    Size 8.2 MB
    Date 29/01/16
    Description
    Providing the certified electrician with information on how to install and connect the Galaxy 300 UPS
    MGE Galaxy 3500, MGE Galaxy 300 and Smart-UPS VT Earthing Principles (Version V0)
    Description
    Contains information about earthing principles for MGE Galaxy 3500, Smart-UPS VT and MGE Galaxy 300
    prp.document.label.format pdf
    Size 2.2 MB
    Date 26/09/14
    Description
    Contains information about earthing principles for MGE Galaxy 3500, Smart-UPS VT and MGE Galaxy 300
    Schneider Electric Important Safety Instructions (Version V0)
    Description
    Schneider Electric Important Safety Instructions in English, Chinese Simplified, French, German, European Spanish, Italian, Russian, Portuguese Brazilian, Dutch, Japanese and Korean
    prp.document.label.format pdf
    Size 1.1 MB
    Date 6/06/14
    Description
    Schneider Electric Important Safety Instructions in English, Chinese Simplified, French, German, European Spanish, Italian, Russian, Portuguese Brazilian, Dutch, Japanese and Korean
    Brochure
    Format
    Size
    Date
    Add to My Documents
    Galaxy 300 Brochure (Version V0)
    Files in document
    pdf
    509.1 KB
    Description
    Galaxy 300 - 3 Phase power protection brochure
    prp.document.label.format zip
    Size 2.6 MB
    Date 12/11/15
    Files in document
    pdf
    509.1 KB
    Description
    Galaxy 300 - 3 Phase power protection brochure
    CAD
    Format
    Size
    Date
    Add to My Documents
    UPS_Galaxy300_Schneider_Electric_10-40kVA_400V_BIM_Model (Version V0)
    Description
    BIM Models, UPS, Galaxy 300
    prp.document.label.format zip
    Size 872.9 KB
    Date 4/09/17
    Description
    BIM Models, UPS, Galaxy 300
    G3HT10K3I30R2M2CLA-SD - Galaxy300 10-30kVA 3-1 with CLA 2 Module N+1 System One Line (Version V2)
    Files in document
    pdf
    217.3 KB
    zip
    250.6 KB
    Description
    MGE Galaxy 300, CLA, System One Line
    prp.document.label.format zip
    Size 467.9 KB
    Date 13/03/16
    Files in document
    pdf
    217.3 KB
    zip
    250.6 KB
    Description
    MGE Galaxy 300, CLA, System One Line
    G3HT10K3I30C1M1CLA-SD - Galaxy300 10-30kVA 3-1 with CLA One Module System One Line (Version V1)
    Files in document
    pdf
    188.6 KB
    zip
    224.5 KB
    Description
    MGE Galaxy 300, CLA, System One Line
    prp.document.label.format zip
    Size 413 KB
    Date 13/03/16
    Files in document
    pdf
    188.6 KB
    zip
    224.5 KB
    Description
    MGE Galaxy 300, CLA, System One Line
    G3HT10K3I30R2M1CLA-SD - Galaxy300 10-30kVA 3-1 with CLA 2 Module N+1 System One Line (Version V1)
    Files in document
    pdf
    213.1 KB
    zip
    244.9 KB
    Description
    MGE Galaxy 300, CLA, System One Line
    prp.document.label.format zip
    Size 458 KB
    Date 13/03/16
    Files in document
    pdf
    213.1 KB
    zip
    244.9 KB
    Description
    MGE Galaxy 300, CLA, System One Line
    G3HT10K3I30C1M2CLA-SD - Galaxy300 10-30kVA 3-1 with CLA One Module System One Line (Version V2)
    Files in document
    pdf
    192.7 KB
    zip
    231.1 KB
    Description
    MGE Galaxy 300, CLA, System One Line
    prp.document.label.format zip
    Size 423.9 KB
    Date 13/03/16
    Files in document
    pdf
    192.7 KB
    zip
    231.1 KB
    Description
    MGE Galaxy 300, CLA, System One Line
    G3HT20K3I30L - MGE Galaxy 300, 20-30kVA, 400V, 3ph in 1ph Out, with Long Backup Charger (Version V3)
    Files in document
    pdf
    708.1 KB
    Description
    MGE Galaxy 300, CLA, 3:1 Version, Mechanicals
    prp.document.label.format zip
    Size 3.1 MB
    Date 1/12/15
    Files in document
    pdf
    708.1 KB
    Description
    MGE Galaxy 300, CLA, 3:1 Version, Mechanicals
    G3HT20K40BAT - MGE Galaxy 300, 20-40kVA, 400V, with CLA and Ext. Battery (Version V0)
    Files in document
    pdf
    506.8 KB
    zip
    903.6 KB
    Description
    MGE Galaxy 300, CLA, Solutions
    prp.document.label.format zip
    Size 1.4 MB
    Date 18/06/10
    Files in document
    pdf
    506.8 KB
    zip
    903.6 KB
    Description
    MGE Galaxy 300, CLA, Solutions
    G3HT10K40CLA-WD - Galaxy300 10-40kVA CLA System Wiring Diagram (Version V0)
    Files in document
    pdf
    222 KB
    zip
    88.1 KB
    Description
    MGE Galaxy 300, CLA, System Wiring Diagram
    prp.document.label.format zip
    Size 310.1 KB
    Date 17/06/10
    Files in document
    pdf
    222 KB
    zip
    88.1 KB
    Description
    MGE Galaxy 300, CLA, System Wiring Diagram
    Certificate
    Format
    Size
    Date
    Add to My Documents
    Galaxy 300 Cmim Declaration of Conformity (Version V0)
    Description
    Cmim Declaration of Conformity
    prp.document.label.format pdf
    Size 123.6 KB
    Date 12/07/19
    Description
    Cmim Declaration of Conformity
    Galaxy 300/300i 10-40 kVA EU Declaration of Conformity (Version V2)
    Description
    EU Declaration of Conformity
    prp.document.label.format pdf
    Size 1.4 MB
    Date 1/11/17
    Description
    EU Declaration of Conformity
    prp.document.label.format pdf
    Size 80.7 KB
    Date 30/08/16
    Description
    Certificate of Origin
    MGE Galaxy 300/ 300i TUV certificate (Version V0)
    Description
    TUV certificate
    prp.document.label.format pdf
    Size 374.6 KB
    Date 1/04/13
    Description
    TUV certificate
    MGE Galaxy 300 CB Certificate (Version V0)
    Description
    CB certificate for sales
    prp.document.label.format pdf
    Size 490.9 KB
    Date 19/03/13
    Description
    CB certificate for sales
    MGE Galaxy300 -RoHS Compliance document (Version V0)
    Description
    RoHS compliance document
    prp.document.label.format pdf
    Size 49.3 KB
    Date 20/03/12
    Description
    RoHS compliance document
    MGE Galaxy 300 -REACH approval document (Version V0)
    Description
    MGE Galaxy 300 REACH approval document
    prp.document.label.format pdf
    Size 56.6 KB
    Date 20/03/12
    Description
    MGE Galaxy 300 REACH approval document
    Specification for tender
    Format
    Size
    Date
    Add to My Documents
    CSI 2004/1995 MGE Galaxy 300 Guide Specification 10-30 400V 3:1 (Version V0)
    Files in document
    pdf
    125.2 KB
    Description
    Bid Spec for MGE Galaxy 300 50/60Hz 400V 3:1
    prp.document.label.format zip
    Size 154.3 KB
    Date 27/09/12
    Files in document
    pdf
    125.2 KB
    Description
    Bid Spec for MGE Galaxy 300 50/60Hz 400V 3:1
    Specification guide
    Format
    Size
    Date
    Add to My Documents
    Technical Specifications for Galaxy 300 & Galaxy 300i (Version V2)
    Description
    Providing information on technical data, facility planning, drawings, and options
    prp.document.label.format pdf
    Size 8.2 MB
    Date 31/07/16
    Description
    Providing information on technical data, facility planning, drawings, and options
    MGE Galaxy 300 - Battery Runtime charts (Version V0)
    Files in document
    pdf
    862.5 KB
    Description
    Battery runtime charts for standard non -modular battery configurations
    prp.document.label.format zip
    Size 3.5 MB
    Date 9/10/12
    Files in document
    pdf
    862.5 KB
    Description
    Battery runtime charts for standard non -modular battery configurations
  • Technical FAQs

    No results found.