Welcome to the Schneider Electric Website

Welcome to our website.

Select your location

View all TeSys D
LC1D65G7 Product picture

LC1D65G7

Green premium brand logo
LC1D65G7 Product picture
LC1D65G7
Green premium brand logo

CONTACTOR 600VAC 65AMP IEC +OPTIONS

Show more characteristics
The maximum number of products that can be compared is 4

LC1D65G7 is replaced by:
Product
Qty
LC1D65AG7
Qty
1
The maximum number of products that can be compared is 4
  • Reason for substitution: End of life
  • Substitution date: 30 December 2009
1
  • Main
    range of product
    TeSys D
    range
    TeSys
    product or component type
    Contactor
    device short name
    LC1D
    contactor application
    Motor control
    Resistive load
    utilisation category
    AC-1
    AC-2
    AC-4
    AC-3
    control circuit type
    AC at 50/60 Hz
    poles description
    3P
    pole contact composition
    3 NO
    [Ie] rated operational current
    80 A (at <60 °C) at <= 440 V AC AC-1 for power circuit
    65 A (at <60 °C) at <= 440 V AC AC-3 for power circuit
    motor power kW
    30 kW at 440 V AC 50/60 Hz (AC-3)
    11 kW at 400 V AC 50/60 Hz (AC-4)
    30 kW at 380...400 V AC 50/60 Hz (AC-3)
    30 kW at 415 V AC 50/60 Hz (AC-3)
    37 kW at 1000 V AC 50/60 Hz (AC-3)
    37 kW at 500 V AC 50/60 Hz (AC-3)
    37 kW at 660...690 V AC 50/60 Hz (AC-3)
    18.5 kW at 220...230 V AC 50/60 Hz (AC-3)
    motor power hp
    10 hp at 230/240 V AC 60 Hz for 1P motors conforming to CSA
    10 hp at 230/240 V AC 60 Hz for 1P motors conforming to UL
    20 hp at 200/208 V AC 60 Hz for 3P motors conforming to CSA
    20 hp at 200/208 V AC 60 Hz for 3P motors conforming to UL
    20 hp at 230/240 V AC 60 Hz for 3P motors conforming to CSA
    20 hp at 230/240 V AC 60 Hz for 3P motors conforming to UL
    5 hp at 115 V AC 60 Hz for 1P motors conforming to CSA
    5 hp at 115 V AC 60 Hz for 1P motors conforming to UL
    50 hp at 460/480 V AC 60 Hz for 3P motors conforming to CSA
    50 hp at 460/480 V AC 60 Hz for 3P motors conforming to UL
    50 hp at 575/600 V AC 60 Hz for 3P motors conforming to CSA
    50 hp at 575/600 V AC 60 Hz for 3P motors conforming to UL
    [Uc] control circuit voltage
    120 V AC 50/60 Hz
    connections - terminals
    Control circuit: screw clamp terminal 1 x 1…4 mm²solid without cable end
    Control circuit: screw clamp terminal 2 x 1…4 mm²solid without cable end
    Control circuit: screw clamp terminal 1 x 1…4 mm²flexible with cable end
    Control circuit: screw clamp terminal 2 x 1…2.5 mm²flexible without cable end
    Power circuit: screw terminals
    Power circuit: screw clamp terminal 2 x 1…25 mm²solid without cable end
    Control circuit: screw clamp terminal 2 x 1…4 mm²flexible with cable end
    Power circuit: screw clamp terminal 1 x 1…35 mm²flexible without cable end
    Power circuit: screw clamp terminal 1 x 1…35 mm²solid without cable end
    Power circuit: screw clamp terminal 2 x 1…25 mm²flexible with cable end
    Power circuit: screw clamp terminal 2 x 1…35 mm²flexible without cable end
    Power circuit: screw clamp terminal 2 x 1…35 mm²solid with cable end
    Complementary
    coil technology
    Without built-in bidirectional peak limiting diode suppressor
    protective cover
    With
    auxiliary contacts type
    type mirror contact 1 NC conforming to IEC 60947-4-1
    type mechanically linked 1 NO + 1 NC conforming to IEC 60947-5-1
    auxiliary contact composition
    1 NO + 1 NC
    control circuit voltage limits
    Drop-out: 0.3...0.6 Uc at 50/60 Hz (at <60 °C)
    Operational: 0.8...1.1 Uc at 50 Hz (at <60 °C)
    Operational: 0.85...1.1 Uc at 60 Hz (at <60 °C)
    [Ui] rated insulation voltage
    Control circuit: 600 V CSA certified
    Control circuit: 600 V UL certified
    Power circuit: 600 V CSA certified
    Power circuit: 600 V UL certified
    Control circuit: 690 V conforming to IEC 60947-1
    Power circuit: 690 V conforming to IEC 60947-1
    [Uimp] rated impulse withstand voltage
    8 kV conforming to IEC 60947
    overvoltage category
    III
    mounting support
    Rail
    Plate
    flame retardance
    V1 conforming to UL 94
    tightening torque
    Control circuit: 1.2 N.m - on screw clamp terminal - with screwdriver flat Ø 6 mm
    Control circuit: 1.2 N.m - on screw clamp terminal - with screwdriver Philips No 2
    Power circuit: 5 N.m - on screw clamp terminal - with screwdriver flat Ø 6 mm
    Power circuit: 5 N.m - on screw clamp terminal - with screwdriver flat Ø 8 mm
    [Ue] rated operational voltage
    Power circuit: <= 690 V AC 25...400 Hz
    [Ith] conventional free air thermal current
    10 A (at 60 °C) for control circuit
    80 A (at 60 °C) for power circuit
    Irms rated making capacity
    140 A AC for control circuit conforming to IEC 60947-5-1
    1000 A at 440 V for power circuit conforming to IEC 60947
    rated breaking capacity
    1000 A at 440 V for power circuit conforming to IEC 60947
    associated fuse rating
    10 A gG for control circuit conforming to IEC 60947-5-1
    125 A gG at <= 690 V coordination type 1 for power circuit
    125 A gG at <= 690 V coordination type 2 for power circuit
    average impedance
    - Ith 80 A 50 Hz for power circuit
    power dissipation per pole
    6.4 W AC-1
    inrush power in VA
    140 VA cos phi 0.75 (at 20 °C)
    160 VA cos phi 0.75 (at 20 °C)
    hold-in power consumption in VA
    13 VA 50 Hz cos phi 0.3 (at 20 °C)
    15 VA 60 Hz cos phi 0.3 (at 20 °C)
    operating time
    12...26 ms closing
    4...19 ms opening
    safety reliability level
    B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1
    B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1
    mechanical durability
    6000000 cycles
    maximum operating rate
    3600 cyc/h 60 °C
    minimum switching current
    5 mA for control circuit
    minimum switching voltage
    17 V for control circuit
    non-overlap time
    1.5 ms on de-energisation between NC and NO contacts
    1.5 ms on energisation between NC and NO contacts
    insulation resistance
    > 10 MOhm for control circuit
    terminals description ISO n°1
    (A1-A2)CO
    (13-14)NO
    (21-22)NC
    height
    127 mm
    width
    75 mm
    depth
    119 mm
    product weight
    1.4 kg
    Environment
    standards
    EN 60947-5-1
    CSA C22.2 No 14
    EN 60947-4-1
    UL 508
    IEC 60947-4-1
    IEC 60947-5-1
    product certifications
    CCC
    UL
    BV
    CSA
    LROS (pending)
    GOST
    RINA
    GL
    DNV
    IP degree of protection
    IP2x conforming to IEC 60529
    IP2x conforming to VDE 0106
    ambient air temperature for operation
    -5…60 °C
    ambient air temperature for storage
    -60…80 °C
    permissible ambient air temperature around the device
    -40…70 °C at Uc
    operating altitude
    3000 m without
    fire resistance
    850 °C conforming to IEC 60695-2-1
    shock resistance
    10 gn contactor opened
    15 gn contactor closed
    vibration resistance
    2 gn 5…300 Hz contactor opened
    4 gn 5…300 Hz contactor closed
    heat dissipation
    4…5 W at 50/60 Hz for control circuit
    Offer Sustainability
    Sustainable offer status
    Green Premium product
    REACh Regulation
    REACh free of SVHC
    Yes
    EU RoHS Directive
    Toxic heavy metal free
    Yes
    Mercury free
    Yes
    RoHS exemption information
    China RoHS Regulation
    Environmental Disclosure
    Circularity Profile
    WEEE
    The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins
    Contractual warranty
    Warranty
    18 months
  • View more View less

    Documents

    Language
    • All Languages10
    • English10
    • Chinese4
    Instruction sheet
    Format
    Size
    Date
    Add to My Documents
    LC1/LC2 D40...D95 - 80 to 95 A contactors and reversing contactors (Version 12)
    Description
    W90444935011411 W904449350114 W90444935 0444935 W90444
    Size pdf
    Size 1.7 MB
    Date 18/02/19
    Description
    W90444935011411 W904449350114 W90444935 0444935 W90444
    CAD
    Format
    Size
    Date
    Add to My Documents
    CAD for LC1D65G7: CONTACTOR 600VAC 65AMP IEC +OPTIONS (Version 1.0)
    Description
    You will be redirected to the ThomasNet website. Then you could download this CAD model in more than 15 different 2D or 3D CAD formats.
    CAD for LC1D65G7: CONTACTOR 600VAC 65AMP IEC +OPTIONS (Version 1.0)
    Description
    You will be redirected to the ThomasNet website. Then you could download this CAD model in more than 15 different 2D or 3D CAD formats.
    Certificate
    Format
    Size
    Date
    Add to My Documents
    Size pdf
    Size 2.2 MB
    Date 22/01/18
    Size pdf
    Size 2.7 MB
    Date 17/07/17
    Size pdf
    Size 263.8 KB
    Date 26/06/14
    China RoHS declaration
    Format
    Size
    Date
    Add to My Documents
    LC1D65G7 : LC1D65G7_ROHS_CHINA_DECLARATION
    Description
    LC1D65G7_ROHS_CHINA_DECLARATION
    Size pdf
    Size 195.3 KB
    Date 26/01/20
    Description
    LC1D65G7_ROHS_CHINA_DECLARATION
    End of Life Information
    Format
    Size
    Date
    Add to My Documents
    Size pdf
    Size 199.4 KB
    Date 1/06/15
    EU RoHS Declaration
    Format
    Size
    Date
    Add to My Documents
    LC1D65G7 : LC1D65G7_ROHS_DECLARATION
    Description
    LC1D65G7_ROHS_DECLARATION
    Size pdf
    Size 195.3 KB
    Date 26/01/20
    Description
    LC1D65G7_ROHS_DECLARATION
    Product Environmental Profile
    Format
    Size
    Date
    Add to My Documents
    Size pdf
    Size 224.4 KB
    Date 1/12/15
    REACh Declaration
    Format
    Size
    Date
    Add to My Documents
    LC1D65G7 : LC1D65G7_REACH_DECLARATION
    Description
    LC1D65G7_REACH_DECLARATION
    Size pdf
    Size 195.3 KB
    Date 26/01/20
    Description
    LC1D65G7_REACH_DECLARATION
  • Technical FAQs

    No results found.
    Unfortunately, related FAQs are unavailable due to temporary technical issues. Please try again later.