Discover Acti9 indication and tripping auxiliaries
Discover Acti9 indication and tripping auxiliaries
Simplified electrical maintenance
Designed with protection and with a wide range of features, the Acti9 indication and tripping auxiliaries combine easy installation with high levels of functionality. It includes:• Automatic reclosing, remote control, remote indication, and tripping.• VisiTrip for quick detection of faulty outgoers and reduced intervention time• Clip-on assembly system for ease of useIt is used for enhanced protection in commercial and industrial buildings, while working on tripped circuits caused by: short-circuit current, overload current, earth fault leakage current, Undervoltage, and manual safety tripping action.
Benefits of Acti9 indication and tripping auxiliaries
Benefits of Acti9 indication and tripping auxiliaries
Multiple combinations
Variety of combinations between electrical auxiliaries: Acti9 iOF + iSD, iOF/SD + iMX, iOF + iMN, and you can connect from top or bottom. Auxiliaries compatible with comb busbars.
Compliant with controllers
Auxiliaries allow you better monitoring of your circuits. They provide the status of an Acti9 miniature circuit breaker, using a low current ( from 2 mA to 100 mA ) within PLC/ controller architecture.
Premium installation
Low current auxiliaries are compliant in a harsh environment. Monitoring up to 100 protective devices (permanently closed) under a daisy chain.
Features
Features
Acti9 auxiliaries for remote indication of the state of the device to which they are connected (fully compliant with IEC 60947-5-1 and, IEC 60947-5-4 for low current auxiliaries): • Remote indication of "open" or "closed" state and of "tripped" state • Instantaneous tripping when the control circuit is energized, de-energized, or if there is a dip in its supply voltage • Time-delayed tripping (to cope with micro-breaks or brief voltage drops) when the control circuit is de-energized, or if there is a dip in its supply voltage • Fail-safe emergency stop trippingSelect the right offer: • For basic applications (from 100mA to 6A), use commercial references A9A2690x. • For low current applications (from 2mA to 100mA), use commercial references A9A2691x. • For Smartlink systems with dedicated connectors, use commercial references A9A2689x.
• Remote electrical control (opening and closing) of circuit breakers with or without Vigi iC60 add-on RCD and with or without auxiliary• Circuit-breaker resetting after tripping, in full accordance with protection principles and regulations• Local control feature via an operating handle.
• Easily perform automatic reclosing of the associated protection device after tripping• Increase the availability of hard to access and isolated installations without supervision (mobile telephony systems, motorways, pumping stations, airports, railways, meteorological stations, service stations, automatic teller machines, public lighting, tunnels, etc.), by restoring them to operate without the need of personal intervention in the event of a transient fault (atmospheric disturbances, industrial overvoltages, etc.).
Applications
Applications
Industrial buildings
Commercial buildings
Critical building
Data center
Machine
Infrastructure
How-to videos
How-to videos
Install Acti9 Auxiliaries
How to distinguish Acti9 electrical auxiliaries and how to mount them with Acti9 MCBs
Acti9 iSD auxiliary
Use and test Acti9 iSD electrical auxiliary
Install Acti9 iOF/SD+OF auxiliary
How to use Acti9 iOF/SD+OF electrical auxiliary.
Cabling of Acti9 iMX+OF auxiliary
How to cable Acti9 iMX+OF electrical auxiliary.