{}

Nossas Marcas

Impact-Company-Logo-English Black-01-177x54

Bem-vindo ao website da Schneider Electric

Bem-vindo ao nosso site.
Como podemos ajudar você hoje?
ACSC1XX Spare Parts List

Article available in these languages: Spanish

Issue:
This document contains the Spare Parts List for ACSC1XX units.

Product line:
ACSC100, ACSC101.

Environment:
All serial numbers.

Cause:
Install, Repair.

Resolution:
Please contact Cooling Tech Support to confirm the part numbers before quoting as some may have changed. 888-695-6500 Option 2, Option 2, Option 2

DESCRIPTION

APC PN#

QTY

Manufacturing #

***USC Special Orders

QAIRDIST-MISC

ASSY CORR BD TWF06 ROHS

0P9028A

1

BAYING BRACKET NETSHELTER SX

870-11538

2

BAYING BRACKET SCREW M5 X 12 FLT UCUT PHIL M5 X 12 BLK (for baying kit)

803-5006A

2

BOX ASSY for DUCT KIT ACSC 5KW

0M-61250

1

CABLE ASSY RELATIVE HUMIDITY SENSOR

W0N-0297[RH1] front

1

CABLE ASSY RELATIVE HUMIDITY SENSOR

W0N-0865[RH2] Rear

1

CABLE ASSY Temperature Humidity Sensor

AP9335TH

CABLE ASSY Temperature Sensor

AP9335T

CABLE ASSY TEMPERATURE SENSORS

0J-0W3163A {8FT.EN_US}

CABLE ASSY TEMPERATURE SENSORS (Rack Inlet)

0J-0W2818A {13FT.EN_US}

1

CAP MTL PPR 400V 5% 40UF RD (compressor)

W234-1406 (234-1406)

CAP MTL PPR 450V 55UF WITH TAP (compressor)

W234-0556 (234-0556)

CASTER STEEL 2" RIGID DARKSTAR (rear)

870-6620

2

CASTER SWIVEL 650 LBS 2.8IN OH (front)

870-71046

2

Ceiling Tile Adapter 24" - Spare Part

W870-80333

Ceiling Tile Adapter 600mm - Spare Part

W870-80336

COMP Assy, SC, ROTARY 208-230/1/60 (Toshiba conversion kit)

W0H-0170

COMP Assy, SC, ROTARY 220-240/1/50 (Toshiba conversion kit)

W0H-0171

COMP, ROTARY 208-230/1/60, SC, TOSHIBA - SPARE PART

W875-3825

1

COMP, ROTARY 220-240/1/50 SC, TOSHIBA - SPARE PART

W875-3826

1

Compressor Wiring Harness (FSB )

W0W3418

CONDENSATE PUMP DUAL ASSY W/HOSES (Dual Condensate Pump)

0N-0993SE

CONDENSATE PUMP FITTING BARBED (Y barb fittings) .13"X.13"X.13" (inlet)

875-4367 (for Dual Condensate Pump)

CONDENSATE PUMP FITTING BARBED (Y barb fittings) .19"X.19"X.19" (outlet)

875-4368 (for Dual Condensate Pump)

CONDENSATE PUMP TUBE PVC .125IN ID .250IN OD (18" long PVC TUBE for 875-4367)

875-0481 (for Dual Condensate Pump)

CONDENSATE PUMP TUBE PVC .188IN ID .313IN OD (18" long PVC TUBE for 875-4368)

875-0857B (for Dual Condensate Pump)

CONDENSATE PUMP TUBE PVC .625IN ID .750OD (2.3 FEET (700 MM) LONG)

875-0482  (for Dual Condensate Pump)

CONDENSATE PUMP WIRE ASSY CP JUMPER (for activation without the water sensor kit)

0W3133

CONDENSATE PUMP WITH Float - Spare Part (Dual voltage 120v/208v)

0J-0011

1

CONDENSER COIL ASSY  SC5

0M-61169

1

Condenser Fan 200mm Mixed Flow (INDIVIDUAL FAN)

W490-0079

3

CONNECTOR SET 17KW IR SPARES for Jumper

W0H-0127

CONVERSION TO TOSHIBA COMP KIT , SC, 50HZ - SPARE PART

W0H-0171

DC RECTIFIER, 500 WATT, 54VDC, WIDE INPUT, FULL SIGNALS, BLACK

W1TWF0500H54B

2

DIVIDER-'A' DUCT KIT ACSC 5KW 48ECT BC NKRAFT

871-3527

3

DIVIDER-'B' DUCT KIT ACSC 5KW 48ECT BC NKRAFT

871-3528

2

Door Key - Spare Part

W870-8135

DRIVER BIT COMBO TORX T20/T30 (tool kit)

815-0001

1

DUCTING KIT  24 INCH IR5

0M-61152 (0M-61250)

1

ELECTRONIC EXPANSION VALVE Harness (HBGP harness )

0W4409

ELECTRONIC EXPANSION VALVE, 3/8" ODF (HGBP)

875-4275A

1

EVAPORATOR FAN MODULE ASSY - 17 KW IR

W0M-61005

3

FAN 12VDC 60X25MM 25CFM ROHS (individual fan)

490-0030

1

FAN FUSE NTC COMPLETE 818 PCB CRAC

0P2390

3

FILTER - NON -WASHABLE PRINTING IR SERIES 2 IN THK

W0B1657

FILTER - WASHABLE IR SERIES 1/2" THK - SPARE PART

W875-2010

FITTING 1/8" BARB 10-32

870-80064

FITTING 1/8" BARB TEE (for air differential pressure switch)

870-80066

1

FLOAT SWITCH BULK MOUNT 4" MNL

0N-0279A

2

FLOAT SWITCH, BULKHEAD MOUNT (single float)

540-0205

1

FILTER-DRIER 3/8"ODF SOLDER

w875-2085

1

FM TOOL KIT SUB ASSY

0M-5383

FOOT LEVELING M10 X 51 L X 28 OD NYLOK

825-0035C

2

Front Door Assembly - Spare Part

W0M-61085

1

GROMMET RUBBER 1 1/2"ID X 1 3/4"GD X 1/8"GW (for power cable at the bottom)

827-0219

2

HI PRESS  SW; OPENS 550PSIG CLOSES 400PSIG

w541-0087

1

20PS11-0003

InRow RC/SC Filter 1/2" Washable - Spare Part (default)

W875-2010

1

JUMPER PHASE SELECT

0W3268

LATCH FLUSH SLAM W/ TUMBLER #333 (for side door panels)

840-0192-333

2

Leak Sensor - 20 ft (6.1 m) (ships with orange sensor [AP9326] & black Cat5e cable)

AP9325

LOCTITE 554 - REFRIGERANT THREAD SEALING

690-0144

0

NMC with CAN controller (Embedded)

WAP9517CAN

32

PCB ASSY 5KDX BOARD SET (MB,WC,XA,DP)

W0P2476

1

PCB ASSY, Motherboard W/SIMM AND Mini-Rhodes

W0P2370

PCB CRAC 2X DP SIMM 805 COMPLETE (differential Pressure Switch)

W0P2354A

1

PCB CRAC MB COMPLETE 801 (motherboard)

W0P2340

1

PCB XA SIMM 879 Complete Assy - Spare Part (XA card)

W0P2342

PowerView - Spare Part

WAP9233

1

PRESSURE TRANSDUCER  2CP5

875-3400

2

PWR Backplane 802 PCB CRAC - Spare Part

W0P2341

1

PWR CORD IEC-C19 FEM TO L6-20P LCDI

960-0126

1

Pwr Cord, 16A, 200-240V, C19 to L6-20

AP9871

REAR DOOR ASSY - 17 KW

0M-61004B

1

Relay Coil 250V 25A DPNO 24DC [compressor relay]

W450-0024

RELAY DPDT 120VAC 8A PC MOUNT

450-0302

1

RELAY PWR SPDT 16A/250V 20A/125V NO 24V

450-0012A

1

SIDE PANEL ASSY - IR SERIES

W0M-61031

4

STRAIN RELIEF HEYCO SR 7N-2 (for control box)

652-07N2

3

TELECOUPLNG 8P8C RJ45 STRAIGHT

750-0034

1

TELECOUPLNG 8P8C RJ45 STRAIGHT (ethernet telecoupler)

W750-0034

TERMINATOR ROHS EXT BATT COMM BOARD (for communication board)

0W04161A

1

Thermistor/Probe EMU Cable ASSY - Spare Part (13FT PURPLE)

W0W2818 (0W2818)

1

TUBE 6 FT 10" DIA FLEX DUCT

875-0922A

3

TUBE PVC .125IN ID .250IN OD

875-0481

TUBE PVC .188IN ID .313IN OD

875-0857B

TUBING PVC CLEAR 0.25ID

660-7001D

TXV VALVE  3/8"ODM X 5/8" ODF R410A 1.5 TON

w875-1002

1

BBIZE-1.5-ZCP180BP5

Wire Assembly Base

W0W3287

WIRE ASSY SC5 COMPRESSOR (for FSB AT0093GB001)

W0W3418

1

WIRE ASSY SC5 LOWER PWR FEED MB

0W3288A

1

WIRE ASSY SC5 PRESSURE SENSING

0W3293B

1

WIRE ASSY SC5 PSU/CP PWR/48VDC OUT

0W3290A

1

WIRE ASSY SC5 UPPER PWR FEED MB

0W3291A

1

WIRE CLIP - BLACK AP9335TH (holds sensor cables)

870-13220

4

WIRE TIE 4X.1X.04 BLK

820-0247-010

2

XFMR ISOLATION1:1.3 MAX253

430-0244

1

1U Airflow Management Blanking Panel Kit (Qty 2) Black

AR8108BLK

1U 19" Black Modular Toolless Airflow Management Blanking Panel - Qty 10

AR8136BLK

1U 19" Black Modular Toolless Airflow Management Blanking Panel - Qty 200

AR8136BLK200

Interior components of a ACSC100 unit

Picture of the complete motherboard set

Complete Parts List

Schneider Electric Brasil

Conheça mais
Linha:
Artigos que podem ser úteis
Conheça mais
Linha: