View all   Altivar 312
Schneider Eletric

ATV312HU55N4

Green premium brand logo
Schneider Eletric
ATV312HU55N4
Green premium brand logo

variable speed drive ATV312 - 5.5kW - 15kVA - 232W - 380..500 V- 3-phase supply

Show more characteristics
The maximum number of products that can be compared is 4. Remove already added products.

  • Main
    range of product
    Altivar 312
    product or component type
    Variable speed drive
    product destination
    Asynchronous motors
    product specific application
    Simple machine
    assembly style
    With heat sink
    component name
    ATV312
    motor power kW
    5.5 kW
    motor power hp
    7.5 hp
    [Us] rated supply voltage
    380...500 V - 15...10 %
    supply frequency
    50...60 Hz - 5...5 %
    network number of phases
    3 phases
    line current
    21.9 A 380 V, Isc = 22 kA
    16.5 A 500 V
    EMC filter
    Integrated
    apparent power
    15 kVA
    maximum transient current
    21.5 A 60 s
    power dissipation in W
    232 W at nominal load
    speed range
    1…50
    asynchronous motor control profile
    Factory set : constant torque
    Sensorless flux vector control with PWM type motor control signal
    electrical connection
    Al1, Al2, Al3, AOV, AOC, R1A, R1B, R1C, R2A, R2B, LI1...LI6 terminal 0.00 in² (2.5 mm²) AWG 14
    L1, L2, L3, U, V, W, PA, PB, PA/+, PC/- terminal 0.02 in² (16 mm²) AWG 6
    supply
    Internal supply for logic inputs 19...30 V 100 mA overload and short-circuit protection
    Internal supply for reference potentiometer (2.2 to 10 kOhm) 10...10.8 V 10 mA overload and short-circuit protection
    communication port protocol
    Modbus
    CANopen
    IP degree of protection
    IP20 on upper part without cover plate
    IP21 on connection terminals
    IP31 on upper part
    IP41 on upper part
    option card
    Communication card CANopen daisy chain
    Communication card DeviceNet
    Communication card Fipio
    Communication card Modbus TCP
    Communication card Profibus DP
    Complementary
    supply voltage limits
    323…550 V
    prospective line Isc
    22 kA
    continuous output current
    14.3 A 4 kHz
    output frequency
    0…500 kHz
    nominal switching frequency
    4 kHz
    switching frequency
    2...16 kHz adjustable
    transient overtorque
    170…200 % of nominal motor torque
    braking torque
    150 % 60 s with braking resistor
    100 % with braking resistor continuously
    150 % without braking resistor
    regulation loop
    Frequency PI regulator
    motor slip compensation
    Automatic whatever the load
    Adjustable
    Suppressable
    output voltage
    <= power supply voltage
    tightening torque
    Al1, Al2, Al3, AOV, AOC, R1A, R1B, R1C, R2A, R2B, LI1...LI6 5.31 lbf.in (0.6 N.m)
    L1, L2, L3, U, V, W, PA, PB, PA/+, PC/- 22.13 lbf.in (2.5 N.m)
    insulation
    Electrical between power and control
    analogue input number
    3
    analogue input type
    AI1 configurable voltage 0...10 V 30 V max 30000 Ohm
    AI2 configurable voltage +/- 10 V 30 V max 30000 Ohm
    AI3 configurable current 0...20 mA 250 Ohm
    sampling duration
    AI1, AI2, AI3 8 ms analog
    LI1...LI6 4 ms discrete
    response time
    AOV, AOC 8 ms analog
    R1A, R1B, R1C, R2A, R2B 8 ms discrete
    linearity error
    +/- 0.2 % output
    analogue output number
    1
    analogue output type
    AOC configurable current 0...20 mA 800 Ohm 8 bits
    AOV configurable voltage 0...10 V 470 Ohm 8 bits
    discrete input logic
    Logic input not wired LI1...LI4), < 13 V
    Negative logic (source) LI1...LI6), > 19 V
    Positive logic (source) LI1...LI6), < 5 V, > 11 V
    discrete output number
    2
    discrete output type
    Configurable relay logic R1A, R1B, R1C) 1 NO + 1 NC - 100000 cycles
    Configurable relay logic R2A, R2B) NC - 100000 cycles
    minimum switching current
    R1-R2 10 mA 5 V DC
    maximum switching current
    R1-R2 2 A 250 V AC inductive, cos phi = 0.4 7 ms
    R1-R2 2 A 30 V DC inductive, cos phi = 0.4 7 ms
    R1-R2 5 A 250 V AC resistive, cos phi = 1 0 ms
    R1-R2 5 A 30 V DC resistive, cos phi = 1 0 ms
    discrete input number
    6
    discrete input type
    LI1...LI6) programmable 24 V, 0…100 mA PLC 3500 Ohm
    acceleration and deceleration ramps
    Linear adjustable separately from 0.1 to 999.9 s
    S, U or customized
    braking to standstill
    By DC injection
    protection type
    Input phase breaks drive
    Line supply overvoltage and undervoltage safety circuits drive
    Line supply phase loss safety function, for three phases supply drive
    Motor phase breaks drive
    Overcurrent between output phases and earth (on power up only) drive
    Overheating protection drive
    Short-circuit between motor phases drive
    Thermal protection motor
    insulation resistance
    >= 500 mOhm 500 V DC for 1 minute
    local signalling
    Drive voltage 1 LED red)
    CANopen bus status four 7-segment display units
    time constant
    5 ms for reference change
    frequency resolution
    Analog input 0.1...100 Hz
    Display unit 0.1 Hz
    connector type
    1 RJ45 Modbus/CANopen
    physical interface
    RS485 multidrop serial link
    transmission frame
    RTU
    transmission rate
    10, 20, 50, 125, 250, 500 kbps or 1 Mbps CANopen
    4800, 9600 or 19200 bps Modbus
    number of addresses
    1…127 CANopen
    1…247 Modbus
    number of drive
    127 CANopen
    31 Modbus
    marking
    CE
    operating position
    Vertical +/- 10 degree
    outer dimension
    442 x 239 x 192 mm
    300 x 210 x 170 mm
    232 x 180 x 170 mm
    402 x 239 x 192 mm
    height
    9.13 in (232 mm)
    width
    7.09 in (180 mm)
    depth
    6.77 in (172 mm)
    net weight
    14.33 lb(US) (6.5 kg)
    Environment
    dielectric strength
    2410 V DC between earth and power terminals
    3400 V AC between control and power terminals
    electromagnetic compatibility
    1.2/50 µs - 8/20 µs surge immunity test level 3 IEC 61000-4-5
    Electrical fast transient/burst immunity test level 4 IEC 61000-4-4
    Electrostatic discharge immunity test level 3 IEC 61000-4-2
    Radiated radio-frequency electromagnetic field immunity test level 3 IEC 61000-4-3
    standards
    IEC 61800-5-1
    IEC 61800-3
    product certifications
    GOST
    DNV
    NOM
    UL
    CSA
    C-Tick
    pollution degree
    2
    protective treatment
    TC
    vibration resistance
    1 gn 13…150 Hz)EN/IEC 60068-2-6
    1.5 mm 3…13 Hz)EN/IEC 60068-2-6
    shock resistance
    15 gn 11 ms EN/IEC 60068-2-27
    relative humidity
    5…95 % without condensation IEC 60068-2-3
    5…95 % without dripping water IEC 60068-2-3
    ambient air temperature for storage
    -13…158 °F (-25…70 °C)
    ambient air temperature for operation
    14…122 °F (-10…50 °C) without derating with protective cover on top of the drive)
    14…140 °F (-10…60 °C) with derating factor without protective cover on top of the drive)
    operating altitude
    <= 1000 m without derating
    1000...3000 m with current derating 1 % per 100 m
    Packing Units
    Unit Type of Package 1
    PCE
    Number of Units in Package 1
    1
    Package 1 Weight
    13.76 lb(US) (6.243 kg)
    Package 1 Height
    10.63 in (27 cm)
    Package 1 width
    9.25 in (23.5 cm)
    Package 1 Length
    11.81 in (30 cm)
    Unit Type of Package 2
    P06
    Number of Units in Package 2
    10
    Package 2 Weight
    166.29 lb(US) (75.43 kg)
    Package 2 Height
    31.50 in (80 cm)
    Package 2 width
    31.50 in (80 cm)
    Package 2 Length
    23.62 in (60 cm)
    Offer Sustainability
    Sustainable offer status
    Green Premium product
    EU RoHS Directive
    Pro-active compliance (Product out of EU RoHS legal scope)
    EU RoHS Declaration
    Mercury free
    Yes
    RoHS exemption information
    China RoHS Regulation
    Environmental Disclosure
    Circularity Profile
    WEEE
    The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins
    Contractual warranty
    Warranty
    18 months
  • View more View less

    Documents

    Language
    • All Languages28
    • English25
    • Chinese4
    • French6
    Catalogue
    Format
    Size
    Date
    Add to My Documents
    prp.document.label.format pdf
    Size 23.3 MB
    Date 01/05/11
    User guide
    Format
    Size
    Date
    Add to My Documents
    prp.document.label.format pdf
    Size 1.2 MB
    Date 10/02/17
    3) ATV312 programming manual (Version 04)
    Description
    V5.1IE57
    prp.document.label.format pdf
    Size 1.8 MB
    Date 06/05/16
    Description
    V5.1IE57
    prp.document.label.format pdf
    Size 1.6 MB
    Date 29/04/16
    1) ATV312 Getting Stated Annex : SCCR (Version 04)
    Description
    Short-Circuit Current Ratings (SCCR) and branch circuit protection The table shows recommended fuse ratings for UL and CSA requirements. The components are for use together in accordance with standard UL508
    prp.document.label.format pdf
    Size 210.6 KB
    Date 29/04/16
    Description
    Short-Circuit Current Ratings (SCCR) and branch circuit protection The table shows recommended fuse ratings for UL and CSA requirements. The components are for use together in accordance with standard UL508
    prp.document.label.format pdf
    Size 2.3 MB
    Date 31/05/13
    prp.document.label.format pdf
    Size 2.8 MB
    Date 30/09/12
    prp.document.label.format pdf
    Size 1.9 MB
    Date 30/09/12
    prp.document.label.format pdf
    Size 2 MB
    Date 29/06/12
    prp.document.label.format pdf
    Size 1.9 MB
    Date 06/05/16
    prp.document.label.format pdf
    Size 1.6 MB
    Date 29/04/16
    prp.document.label.format pdf
    Size 3.7 MB
    Date 31/05/13
    Data Bulletin
    Format
    Size
    Date
    Add to My Documents
    Variable Frequency Drives and Short-Circuit Current Ratings (Version 2.0)
    Description
    This data bulletin clarifies the terms and standards used in the industry, explains the thermal impact of PSCC values on VFDs, and provides VFD installation ratings information. This bulletin also includes discussion on when to specify or install line reactors or DC chokes, and the aspects of installing a VFD without using an enclosure. In addition, the reader will understand how the cost of a VFD installation is directly proportional to the SCCR level specified.
    prp.document.label.format pdf
    Size 672.9 KB
    Date 31/01/17
    Description
    This data bulletin clarifies the terms and standards used in the industry, explains the thermal impact of PSCC values on VFDs, and provides VFD installation ratings information. This bulletin also includes discussion on when to specify or install line reactors or DC chokes, and the aspects of installing a VFD without using an enclosure. In addition, the reader will understand how the cost of a VFD installation is directly proportional to the SCCR level specified.
    CAD
    Format
    Size
    Date
    Add to My Documents
    AC DRIVE 7.5 HP 480V 3 PHASE (Version 1.0)
    Files in document
    dxf
    1.9 MB
    dwg
    355.2 KB
    dwf
    107.5 KB
    pdf
    47.5 KB
    prp.document.label.format zip
    Size 2.4 MB
    Date 24/10/17
    Files in document
    dxf
    1.9 MB
    dwg
    355.2 KB
    dwf
    107.5 KB
    pdf
    47.5 KB
    Certificate
    Format
    Size
    Date
    Add to My Documents
    prp.document.label.format pdf
    Size 599.1 KB
    Date 20/04/16
    prp.document.label.format pdf
    Size 741.2 KB
    Date 28/02/12
    prp.document.label.format pdf
    Size 527.5 KB
    Date 19/04/10
    Instruction sheet
    Format
    Size
    Date
    Add to My Documents
    prp.document.label.format pdf
    Size 389.4 KB
    Date 31/07/18
    prp.document.label.format pdf
    Size 675.9 KB
    Date 28/02/18
    prp.document.label.format pdf
    Size 1.1 MB
    Date 15/02/10
    China RoHS declaration
    Format
    Size
    Date
    Add to My Documents
    ATV312HU55N4 : variable speed drive ATV312 - 5.5kW - 15kVA - 232W - 380..500 V- 3-phase supply
    Description
    variable speed drive ATV312 - 5.5kW - 15kVA - 232W - 380..500 V- 3-phase supply
    prp.document.label.format pdf
    Size 195.3 KB
    Date 15/08/20
    Description
    variable speed drive ATV312 - 5.5kW - 15kVA - 232W - 380..500 V- 3-phase supply
    End of Life Information
    Format
    Size
    Date
    Add to My Documents
    prp.document.label.format pdf
    Size 233.6 KB
    Date 01/10/11
    prp.document.label.format pdf
    Size 251.9 KB
    Date 01/10/10
    EU RoHS Declaration
    Format
    Size
    Date
    Add to My Documents
    ATV312HU55N4 : variable speed drive ATV312 - 5.5kW - 15kVA - 232W - 380..500 V- 3-phase supply
    Description
    variable speed drive ATV312 - 5.5kW - 15kVA - 232W - 380..500 V- 3-phase supply
    prp.document.label.format pdf
    Size 195.3 KB
    Date 15/08/20
    Description
    variable speed drive ATV312 - 5.5kW - 15kVA - 232W - 380..500 V- 3-phase supply
    Marine certificate
    Format
    Size
    Date
    Add to My Documents
    prp.document.label.format pdf
    Size 267.4 KB
    Date 02/08/18
    Product Environmental Profile
    Format
    Size
    Date
    Add to My Documents
    Instruction Sheet: China RoHS - Hazardous Substances Table (Version 01)
    Description
    This table is made according to SJ/T 11364. O: indicates that the concentration of hazardous substance in all of the homogeneous materials for this part is below the limit as stipulated in GB/T 26572. X: indicates that concentration of hazardous substance in at least one of the homogeneous materials used for this part is above the limit as stipulated in GB/T 26572
    prp.document.label.format pdf
    Size 1.1 MB
    Date 30/05/16
    Description
    This table is made according to SJ/T 11364. O: indicates that the concentration of hazardous substance in all of the homogeneous materials for this part is below the limit as stipulated in GB/T 26572. X: indicates that concentration of hazardous substance in at least one of the homogeneous materials used for this part is above the limit as stipulated in GB/T 26572
    prp.document.label.format pdf
    Size 193.3 KB
    Date 01/02/11
    Handout
    Format
    Size
    Date
    Add to My Documents
    Altivar 312 Keypad Quick Reference User Guide (Version 1.0)
    Description
    This handout is a quick reference guide for the Altivar 312 keypad. Topics covered: Keypad operation, Access to menus, full chart of Altivar 312 keypad menu options. Altivar 312 general wiring diagrams, control terminals functions, and electrical characteristics.
    prp.document.label.format pdf
    Size 544.2 KB
    Date 01/01/15
    Description
    This handout is a quick reference guide for the Altivar 312 keypad. Topics covered: Keypad operation, Access to menus, full chart of Altivar 312 keypad menu options. Altivar 312 general wiring diagrams, control terminals functions, and electrical characteristics.
  • View more View less

    Software and Firmware

    Language
    • All Languages1
    • English1
    • Chinese1
    • French1
    • German1
    • Italian1
    • Portuguese1
    • Spanish1
    • Turkish1
    Software - Released
    Format
    Size
    Date
    Add to My Documents
    SoMove (FDT Standalone) (Version V2.8.2)
    Files in document
    exe
    328.5 MB
    Description
    Requires additional device DTM libraries download from our website
    prp.document.label.format zip
    Size 328.6 MB
    Date 27/07/20
    Files in document
    exe
    328.5 MB
    Description
    Requires additional device DTM libraries download from our website
  • Technical FAQs

    No results found.
    Unfortunately, related FAQs are unavailable due to temporary technical issues. Please try again later.