OPC Factory Server - Service Pack 2

OPC Factory Server V3.60.3110 SP2 Enhancements - Bug Fixing : Bug fixing : Active items may not access devices at the actual group update rate. OPC groups update rate is now revised (through IOPCServer::AddGroup or IOPCGroupStateMgt::SetState) to the nearest multiple of 50ms (for instance 420ms is revised to 400ms, 430ms to 450ms). Minimum supported update rate is 300ms (500ms for TimeStamp event group). Bug fixing : Unity data dictionnary loading may fail on Unity application modified without explicit build command. Bug fixing : A memory leak occured on Synchronous or Asynchronous Read operations. Bug fixing : #PLCQualStatus may not reflect the actual device connection status when used as a single active item on event sources, devices without alias or with alias with /Q or /NQ postfix. Bug fixing : #TSEventSynchro write operation could not be interrupted on a missing event source. It is now interrupted after a certain amount of retries. Bug fixing : PLC event sources configured with redundant addresses may be badly managed on TimeStamp Event Group activation\ deactivation sequences. Enhancement : #SwitchPrimaryAddress value and quality are updated as below : Read value 0: indicates that primary communication path is Device Address A. Read value 1: indicates that primary communication path is Device Address B. Read value 2: indicates that standby communication path is not configured (new feature) Quality QUAL_BAD : Communication with the device is interrupted, the primary, and standby communication paths are OFFLINE. Quality QUAL_UNCERTAIN : Communication with the device is correct but the standby communication path is OFFLINE (new feature) Quality QUAL_GOOD : Communication with the device is correct, the primary and standby communication paths are ONLINE

Fecha: 01 ago 2016 | Tipo: Software
Idiomas: Inglés | Versión: V3.60 SP2
Referencia del documento: OFS_3_60_3110_SP2

Archivos

Nombre del archivo
OFS_V3.60_3110_DEMO_SP2.zip
OFS_V3.60_3110_LARGE_SP2.zip
OFS_V3.60_3110_SMALL_SP2.zip
content.htm

¿Necesitas ayuda?

Comienza aquí

Encuentra respuestas ahora. Busca una solución por tu cuenta o conéctate con uno de nuestros expertos.

Comunícate con el centro de soporte

Comunícate con nuestro equipo de Atención al Cliente para recibir más información, soporte técnico, asistencia con respecto a reclamos y más.

¿Dónde puedo adquirirlo?

Encuentra fácilmente el distribuidor de Schneider Electric más cercano a ti.

 opens in new Window

Explora las preguntas frecuentes

Obtén las respuestas que necesitas en la sección de preguntas frecuentes (FAQ) relacionadas con el tema.

 opens in new Window

Contacta con el servicio de ventas

Comienza tu consulta de ventas en línea y un experto se pondrá en contacto contigo.