Issue:
ACPA4000 Spare Parts List
Product line:
ACPA4000
Environment:
All Serial Numbers
Cause:
Parts
Resolution:
Please contact Cooling Tech Support to confirm the part numbers before quoting as some may have changed. 888-695-6500 Option 2, Option 2, Option 2
ACPA4000 Spare Parts List
Product line:
ACPA4000
Environment:
All Serial Numbers
Cause:
Parts
Resolution:
Please contact Cooling Tech Support to confirm the part numbers before quoting as some may have changed. 888-695-6500 Option 2, Option 2, Option 2
Description | APC PN# |
ASSY PUMP CONDENSATE WITH FLOAT | 0N-0228A |
CABLE POWERVIEW ACPA (cable from CAT-5e coupler to Display) | 0W1621 |
CAP MTL PPR 20UF 10% 370VAC -20C TO 70C (condenser) QTY 3 | 234-4206 |
CAP MTL PPR 45UF 10% 370VAC (compressor) QTY 2 | 234-0456 |
CASTER 50MM LOCKING (REAR) | 870-3787 |
CASTER FRONT BARROW (FRONT) | 870-3520 |
Ceiling Tile Adapter (for drop ceiling) | 870-3641A |
CKT BRKR 20A 250VAC UL/VDE (Rear of the unit) | 530-0850 |
COIL COND 18 X 15 2ROW 14 FPI (condenser coil) | 875-0428B |
COIL EVAP 14 X 13.50 2 ROW (evaporator coil) | 875-0427A |
COMPLETE 872 PCB ASSY NPOLE (Barrow - Brain Board) | W0P4576 |
COMPLETE 873 PCB ASSY NPOLE (Powerboard - all 120v comes through here) | W0P4577 |
COMPLETE 878 PCB ASSY NPOLE (supply/return temperature sensor) | 0P4582 |
COMPRESSOR ROTARY 115/1/60 (PANASONIC style compressor) (CAT2P16S3R126B-1A) | 875-3544 |
Condensate Drain hose (PVC Tube .125IN ID .250IN OD) | 875-0481 |
Condensate Drain QUICK DISCONNECT COUPLER Sub Assembly (rear drain disconnect) | 0M-2725 |
Condensate Pump Door Assy (Includes Pump)[do not rma] | 0M-6326A |
Condensate Pump EC-400 Little Giant (YK0501 below) (this pump only) | 491-0464 |
Condensate Pump Pacific Yellow PCF3000.4 (YK0501 above) (120V/230V - AutoSelect) (you need to ship this with the water sensor pn#W0H-0213 ) | W0N-7166 |
Condensate Tray with Dual float (actual condensate tray) | 870-3640 |
Condenser Duct Tubing (Assy. Intake/Exhaust DUCT 10 FT X 8 IN) | 0M-2411 |
Condenser Exhaust Kit (includes hose connectors & ceiling tile) | 0M-2470 |
Condenser Fan (fan only) | 490-1045 |
Condenser Fan Box Sub Assy (fan housing assy) | 0M-5034B (0M2483) |
CONN PLUG 12 POS 3.5MM (connects to Barrow Control Board) | 715-0105 |
DEFLECTOR ROOF ADAPTER ACPA (ceiling air deflector) | 870-3662 |
DISCHARGE BYPASS ADRI-1-1 _4- 0_ 75 (HGBP) | W875-4198 |
Duct Collars (connects ducts to the unit and ceiling) | 870-3663 |
Evaporator Fan Box Assy (fan only) | 490-1046 |
Evaporator Fan Box Sub Assy (fan w/ housing assy) | 0M-5033A |
Filter 16 x 16 x 2 (air filter kit; ships w/3 filters) | ACPA4000RF |
Filter 16 x 16 x 2 (individual) | 875-2145 |
Filter Drier (Liquid Line Filter Drier) (C-033-S) | 875-2131 |
Float Switch (dual floats) | 540-0097 |
FLOAT SWITCH, BULKHEAD MOUNT (single float) | 540-0205 |
HARNESS BOARD INTERCONNECT ACPA | 0W1618C |
HARNESS For POWER VIEW (connects to powerview from board) | 0W1623 |
HIGH PRESSURE SWITCH (CO 350 PSI CI 250 PSI) | 540-0087 |
LABEL POWERVIEW NETWORKAIR | 885-1577 |
LEUR CHECK VALVE ASSEMBLY (condensate pump check valve assy) | 0M-6332 |
LUER CHECK VALVE ACPA (condensate pump check valve) | 870-11676 |
PowerView Display (a.k.a. thermostat, display, controller, interface, control pad) | AP9231E |
Pwr Cord, 20A, 100-120V, C19 to 5-20 (OPTIONAL Power Cord w/out GFCI) | AP9873 |
Pwr Cord, 20A, 100-120V, C19 to L5-20 (OPTIONAL Power Cord) | AP9874 |
Pwr Cord, 20A, 100-120V, Spare Part (White w/ GFCI) | 0W3401 |
Pwr Cord, 3M IEC309-16A TO C19 V-LOCK (OPTIONAL Power Cord Black) | 960-0121 |
Quick connect for drain (condensate drain line on the rear of the unit) | 0M-2726 |
Quick Disconnect Body (condensate pump) | 875-0854 |
RELAY 120V/15A SPDT 120V COIL (Evaporator) (AZ2280-1C-120A) | 450-0001 |
Replacement Breaker (Unit Circuit Breaker) | 530-1200 |
SWITCH DIFFERENTIAL PRESSURE 0-2 INWG P232 (air differential pressure switch) | 540-0088 |
Switch Thermal Overload Protector (for compressor pecker head) | 540-0128 |
TELECOUPLNG 8P8C RJ45 STRAIGHT (ethernet telecoupler) | W750-0034 |
Temperature & Humidity Sensor (Remote) | AP9512THBLK |
TEV SPORLAN BBIVE-1-CP100-B20 (BBIVE-1-CP100-B20) | 875-4199A |
TUBE TWIN INSERT 1/8" (O-ring) (condensate pump) | 875-0853 |
Water Carry-Over-Kit (Air Dam kit 870-0656) | 0M-0844 |
Water Sensor Kit For ACPA4000 (you need to ship this with the condensate pump pn# W0N-7166) | W0H-0213 |
WIRE HARNESS 10" SMART-SLOT (connects NMC to the brain board) | 0W0436 |
Services Description: | Price: |
1 Year Extended Warranty for NetworkAir ACPA4000 (WEXTWAR1YR-AX-12) | $369.99 |
LABEL HOLD FOR FAILURE ANALYSIS | 885-3997 |