Estonia

Tere tulemast ettevõtte Schneider Electric veebisaidile

Tere tulemast meie veebisaidile.

Saadaolevate toodete vaatamiseks võite valida muu riigi. Ettevõtte teabe nägemiseks avage meie ülemaailmne veebisait.

Valige teine riik või regioon

GV3P136 Pildi tuvastamine Schneider Electric

Kuva kõik TeSys GV3

TeSys GV3 - GV3P136

Thermal-magnetic motor circuit breakers

GV3P136 Pildi tuvastamine Schneider Electric
Kuva kõik TeSys GV3
TeSys GV3 - GV3P136
Thermal-magnetic motor circuit breakers

TeSys GV3 - Circuit breaker - thermal-magnetic - 9…13A - lugs-ring terminal

Näita veel tunnuseid >
Lisa jaotisesse Minu tooted Lisa jaotisesse Minu tooted

  • Main
    range
    TeSys
    product name
    TeSys GV3
    device short name
    GV3P
    product or component type
    Circuit breaker
    device application
    Motor
    trip unit technology
    Thermal-magnetic
    Complementary
    poles description
    3P
    network type
    AC
    utilisation category
    AC-3 conforming to IEC 60947-4-1
    Category A conforming to IEC 60947-2
    network frequency
    50/60 Hz conforming to IEC 60947-4-1
    fixing mode
    Clipped on 35 mm symmetrical DIN rail
    Screwed on panel (with 3 x M4 screws)
    operating position
    Any position
    motor power kW
    11 kW at 690 V AC 50/60 Hz
    7.5 kW at 500 V AC 50/60 Hz
    5.5 kW at 400/415 V AC 50/60 Hz
    breaking capacity
    50 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2
    100 kA Icu at 230/240 V AC 50/60 Hz conforming to IEC 60947-2
    100 kA Icu at 400/415 V AC 50/60 Hz conforming to IEC 60947-2
    6 kA Icu at 690 V AC 50/60 Hz conforming to IEC 60947-2
    12 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2
    [Ics] rated service short-circuit breaking capacity
    100 % at 230/240 V AC 50/60 Hz conforming to IEC 60947-2
    100 % at 440 V AC 50/60 Hz conforming to IEC 60947-2
    50 % at 500 V AC 50/60 Hz conforming to IEC 60947-2
    50 % at 690 V AC 50/60 Hz conforming to IEC 60947-2
    100 % at 400/415 V AC 50/60 Hz conforming to IEC 60947-2
    control type
    Rotary knob
    [In] rated current
    13 A
    thermal protection adjustment range
    9...13 A
    magnetic tripping current
    182 A
    [Ue] rated operational voltage
    690 V AC 50/60 Hz conforming to IEC 60947-2
    [Ui] rated insulation voltage
    690 V AC 50/60 Hz conforming to IEC 60947-2
    [Ith] conventional free air thermal current
    13 A conforming to IEC 60947-4-1
    [Uimp] rated impulse withstand voltage
    6 kV conforming to IEC 60947-2
    power dissipation per pole
    8 W
    mechanical durability
    50000 cycles
    electrical durability
    50000 cyclesfor AC-3at 440 V In
    operating rate
    25 cyc/h
    rated duty
    Continuous conforming to IEC 60947-4-1
    connection pitch
    17.5 mm without spreaders
    connections - terminals
    Lugs-ring terminals external diameter : 6 mm
    Bars 6 x 13.5 mm
    tightening torque
    6 N.m on bars M6 screw type
    6 N.m on lugs-ring terminals M6 screw type
    suitability for isolation
    Yes conforming to IEC 60947-1
    phase failure sensitivity
    Yes conforming to IEC 60947-4-1
    height
    132 mm
    width
    55 mm
    depth
    136 mm
    product weight
    0.96 kg
    Environment
    standards
    EN/IEC 60947-1
    EN/IEC 60947-2
    EN/IEC 60947-4-1
    UL 508 type E
    CSA C22.2 No 14-05 type E
    product certifications
    ATEX
    BV
    CCC
    CSA
    DNV
    GL
    LROS (pending)
    RINA
    UL
    EAC
    protective treatment
    TH
    IP degree of protection
    IP20 conforming to IEC 60529
    IK degree of protection
    IK09
    ambient air temperature for operation
    -20...60 °C
    ambient air temperature for storage
    -40...80 °C
    fire resistance
    960 °C conforming to IEC 60695-2-1
    operating altitude
    3000 m
    Offer Sustainability
    Sustainable offer status
    Green Premium product
    RoHS (date code: YYWW)
    REACh
    Product environmental profile
    Product end of life instructions
    Contractual warranty
    Warranty period
    18 months
  • Tagasi

    Keel
    • Spanish
    • Portuguese
    • Russian
    • French
    • Italian
    • German
    • Chinese
    • English
    Kasutusjuhend
    Kuupäev
    Suurus
    Lisa mu lemmikutesse
    TeSys GV3P - Use in explosive atmospheres (Versioon 05)
    CAD
    Kuupäev
    Suurus
    Lisa mu lemmikutesse
    GV3P MOTOR CB THERM/MAG LUGS (Versioon 1.0)
    Kuupäev 19.12.17
    Suurus 786.8 KB
    Kuupäev 19.12.17
    Suurus 583.4 KB
    Instruktsioonid
    Kuupäev
    Suurus
    Lisa mu lemmikutesse
    GV3 P..6/L..6 - Circuit breaker with lugs (Versioon 07)
    Kasutuselt kõrvaldamise teave
    Kuupäev
    Suurus
    Lisa mu lemmikutesse
    End-of-Life Instructions TeSys GV3P (Versioon 1.0)
    Kuupäev 22.01.16
    Suurus 352.6 KB
    Toote keskkonnaprofiil
    Kuupäev
    Suurus
    Lisa mu lemmikutesse
    TeSys GV3 motor circuit breakers (Versioon 3.0)
    Kuupäev 10.08.17
    Suurus 272 KB
    Vastavusdeklaratsioon
    Kuupäev
    Suurus
    Lisa mu lemmikutesse
    EU Declaration TeSys GV3 - GV3P (Versioon 1.0)
    Kuupäev 14.07.18
    Suurus 568.5 KB