Catalogue
Language
Format
Size
Date
English
prp.document.label.format
pdf
Size
14.5 MB
Date
12/18/19
User guide
Language
Format
Size
Date
Modicon M580 Distributed PAC - Composite Automation Type Online Help
(Version 01)
Description
This manual describes the hardware and software implementation of Modicon X80 analog/digital input/output modules that are configured in a Modicon M580 Distributed PAC system, when configured with EcoStruxureTM Automation Expert.
English
prp.document.label.format
pdf
Size
10.1 MB
Date
12/1/20
Description
This manual describes the hardware and software implementation of Modicon X80 analog/digital input/output modules that are configured in a Modicon M580 Distributed PAC system, when configured with EcoStruxureTM Automation Expert.
Modicon M580 - BMED581020(C) Distributed PAC, User Guide
(Version 01)
Description
This guide provides detailed information about the Modicon M580 distributed programmable automation controller (dPAC), BMED581020(C), and related hardware when configured with EcoStruxure™ Automation Expert software in a standalone M580 system that utilizes the IEC 61499 standard. The BMED581020(C) CPU is not compatible with BMEP58•••• and BMEH58•••• CPUS, which are configured with Control Expert software. The BMED581020(C) CPU does not support a Hot Standby system.
English
prp.document.label.format
pdf
Size
736.4 KB
Date
11/1/20
Description
This guide provides detailed information about the Modicon M580 distributed programmable automation controller (dPAC), BMED581020(C), and related hardware when configured with EcoStruxure™ Automation Expert software in a standalone M580 system that utilizes the IEC 61499 standard. The BMED581020(C) CPU is not compatible with BMEP58•••• and BMEH58•••• CPUS, which are configured with Control Expert software. The BMED581020(C) CPU does not support a Hot Standby system.
ATEX / IECEx INSTRUCTION GUIDE, concerning the use of M340 and M580 Industrial Programmable Controllers for applications in potentially explosive atmosphere
(Version 05)
Description
The present document applies when the modules bear the Ex marking and provides important information forM340-M580 automation system used in Ex zones 2 and 22.It is supplied in English only with ATEX and IECEx certified power supply modules BMXCPS3020H,BMXCPS4022H, and BMXCPS4022S.
English
prp.document.label.format
pdf
Size
973.7 KB
Date
9/1/20
Description
The present document applies when the modules bear the Ex marking and provides important information forM340-M580 automation system used in Ex zones 2 and 22.It is supplied in English only with ATEX and IECEx certified power supply modules BMXCPS3020H,BMXCPS4022H, and BMXCPS4022S.
Modicon M580 - Open Ethernet Network, System Planning Guide
(Version 00)
Description
This document presents usage of industrial Ethernet managed switches with the Modicon M580 offer. A switch centric architecture provides flexibility and openess on system network design.This guide provides detailed information about planning such M580 open architecture, including the following:- topology rules and recommendations for designing an open network architecture- implementation of industrial managed Ethernet Switches- system commissioning and maintenance- system performance and limitations- system diagnostics
English
prp.document.label.format
pdf
Size
1.6 MB
Date
4/1/20
Description
This document presents usage of industrial Ethernet managed switches with the Modicon M580 offer. A switch centric architecture provides flexibility and openess on system network design.This guide provides detailed information about planning such M580 open architecture, including the following:- topology rules and recommendations for designing an open network architecture- implementation of industrial managed Ethernet Switches- system commissioning and maintenance- system performance and limitations- system diagnostics