Micrologic Trip Units

To be filled

Part of Pact Series

For PowerPact P- and R-frame and Masterpact NW/NT power circuit breakers.

Micrologic Trip Units
  • Features

    PowerPact® P- and R-frame molded case circuit breakers and all Masterpact® power circuit breakers are equipped with the Micrologic® trip system to protect power circuits and loads. Micrologic trip systems use a set of current transformers (called CTs or sensors) to sense the current, a trip unit to evaluate the current m and a tripping solenoid to trip the circuit breaker. Micrologic trip-units are field-interchangeable.

    Protection Level

    2.0 – LS0: Long Time+ Short Time+ Zero Delay protection, IEC rated
    3.0 – LI: Long Time + Instantaneous protection, UL Listed and ANSI Certified
    5.0 – LSI: Long Time + Short Time + Instantaneous protection, UL Listed, ANSI Certified, and IEC Rated
    6.0 – LSIG: Long Time + Short Time + Instantaneous + Ground fault protection, UL Listed, ANSI Certified, and IEC Rated

    Models
    Micrologic (Standard) 2.0, 3.0 and 5.0 Trip Units
    • True RMS sensing
    • LI, LSI trip configurations
    • LS0 trip configuration for IEC
    • Field-interchangeable long-time rating plugs
    • LED long-time pickup indication
    • Test kits available
    • Thermal imaging
    Micrologic (Ammeter) 2.0A, 3.0A, 5.0A and 6.0A Trip Units

    Includes all features listed for Micrologic standard trip unit, as well as:

    • LI, LSI, LSIG trip configurations
    • LS0 trip configuration for IEC
    • Digital ammeter—phase and neutral (4-pole only)
    • Phase loading bar graph
    • LED trip indication
    • Zone-selective interlocking (ZSI) (short-time & ground-fault)
    • Optional Modbus® communications—PowerLogic® compatible
    Micrologic (Power) 5.0P and 6.0P Trip Units

    Power measurement and advanced protection features includes all features listed for Micrologic ammeter trip unit, as well as:

    • LSI trip configuration with programmable ground fault alarm
    • LSIG (Ground-fault trip) with programmable ground fault alarm
    • Incremental “fine tuning” of L, S, I, and G pickup and delay settings
    • LCD dot matrix display and LED trip indication
    • Advanced user interface
    • Advanced protection IDMTL—selectable long-time delay bands
    • Neutral protection
    • Power measurement
    • Contact wear indication
    • Modbus communications—PowerLogic compatible
    • Local and remote settings
    Micrologic (Harmonic) 5.0H and 6.0H Trip Units

    Power quality measurement and advanced protection features. Includes all features listed for the Micrologic P (Power) trip unit, as well as:

    • Enhanced power measurements functions
    • Power quality measurements