Egypt and North East Africa (English)

Welcome to the Schneider Electric Website

Welcome to our website.

You can choose another country to view available products or go to our Global website for company information.

Choose another country or region

52404 Product picture Schneider Electric

View all Detuned reactors

Detuned reactors - 52404

Legacy Products

52404 Product picture Schneider Electric
View all Detuned reactors
Detuned reactors - 52404
Legacy Products

inductance - detuned reactor - 12.5 kvar 400..415V 50 Hz - tuning order 4.3

Show more characteristics >
Add to My Products Remove from My Products

  • Main
    range of product
    Varplus
    device short name
    DR
    product or component type
    Detuned reactor
    network frequency
    50 Hz
    reactive power rating
    12.5 kvar at 400...415 V AC 50 Hz
    network rated voltage
    400...415 V AC 50 Hz
    tuning order
    4.3 - 215 Hz - 5.7 % - 50 Hz
    Complementary
    power losses
    150 W
    value of inductance
    2.37 mH
    inductance tolerance
    - 5 % to 5 % per phase
    fundamental current rating
    17.9 A
    electrical insulation class
    Class H
    [Ui] rated insulation voltage
    1.1 kV
    dielectric test voltage
    4 kV for 1 minute at 50 Hz
    [Imp] maximum permanent current
    1.31 x I1
    harmonic current spectrum
    19 % x I7
    2 % x I3
    6 % x I11
    69 % x I5
    dynamic withstand current
    2.2 x Isc
    [Ith] conventional free air thermal current
    2 A at 250 V AC 50 Hz
    type of installation
    Indoor installation
    type of cooling
    Natural
    connections - terminals
    Screw type connector
    fixing center
    205 x 110 mm
    height
    230 mm
    width
    245 mm
    depth
    140 mm
    product weight
    12 kg
    Environment
    standards
    EN 60289
    IEC 60289
    IP degree of protection
    IP00
    operating altitude
    <= 2000 m
    ambient air temperature for operation
    0...55 °C at <= 1000 m
    0...50 °C at > 1000...2000 m
    average ambient air temperature for operation
    50 °C at <= 1000 m (average over 24 hours)
    40 °C at <= 1000 m (average over 1 year)
    45 °C at > 1000...2000 m (average over 24 hours)
    35 °C at > 1000...2000 m (average over 1 year)
    climatic withstand
    Relative humidity: 20...80 %
    Salt mist (400 V/50 Hz) : 250 hours
    Contractual warranty
    Warranty period
    18 months
  • Documents & Downloads

    Language
    • English
    User guide
    Date
    Size
    Add to My Documents
    User manual Detuned reactor (English)
  • Technical FAQs

    No results found
    Unfortunately, related FAQs are unavailable due to temporary technical issues. Please try again later.