  • Main
    range of product
    Modicon X80
    product or component type
    Power supply module
    backplane compatibility
    All backplane
    advanced diagnostics available via network
    Temperature sensing
    Redundancy test
    Uptime duration
    Redundancy information
    Remaining lifetime
    primary voltage
    100...240 V
    supply circuit type
    AC
    secondary power
    18 W 3.3 V DC at 0…60 °C I/O module logic power supply
    40 W 24 V DC at 0…60 °C I/O module power supply and processor if 3.3 V not loaded
    Complementary
    primary voltage limit
    85...264 V
    network frequency
    50/60 Hz
    network frequency limits
    47…63 Hz
    apparent power
    0.07 kVA
    input current
    0.52 A 240 V
    1.04 A 115 V
    inrush current
    30 A 120 V
    60 A 240 V
    I²t on activation
    1 A².s 120 V
    3 A².s 240 V
    It on activation
    0.05 A.s 120 V
    0.07 A.s 240 V
    protection type
    Internal fuse not accessible for primary circuit
    Overload protection for secondary circuit
    Overvoltage protection for secondary circuit
    Short-circuit protection for secondary circuit
    current at secondary voltage
    5.5 A 3.3 V DC I/O module logic power supply
    1.67 A 24 V DC I/O module power supply and processor
    maximum power dissipation in W
    8.5 W
    status LED
    1 LED (green)presence of voltages (OK):
    1 LED (green)redundancy OK:
    1 LED (green)power supply status:
    control type
    RESET push-button cold restart
    electrical connection
    1 connector 2 pin(s)alarm relay
    1 connector 5 pin(s)line supply, protective earth
    insulation resistance
    >= 100 MOhm primary/ground
    >= 100 MOhm primary/secondary
    net weight
    0.51 kg
    Environment
    immunity to microbreaks
    1 ms
    dielectric strength
    1500 V primary/secondary I/O module logic power supply
    1500 V primary/secondary I/O module power supply and processor
    2300 V primary/secondary sensor power supply
    1500 V primary/ground
    500 V 24 V sensor output/ground
    vibration resistance
    3 gn
    shock resistance
    30 gn
    IP degree of protection
    IP20
    directives
    2014/35/EU - low voltage directive
    2014/30/EU - electromagnetic compatibility
    2012/19/EU - WEEE directive
    product certifications
    CE
    RCM
    UL
    Merchant Navy
    CSA
    EAC
    standards
    EN 61131-2
    EN 61000-6-4
    EN 61000-6-2
    EN 61010-2-201
    ambient air temperature for storage
    -40…85 °C
    ambient air temperature for operation
    0…60 °C
    relative humidity
    5…95 % at 55 °C without condensation
    protective treatment
    TC
    Conformal coating Humiseal 1A33
    environmental characteristic
    3C3 conforming to EN/IEC 60721-3-3
    3C4 conforming to EN/IEC 60721-3-3
    operating altitude
    0...2000 m
    2000...5000 m with derating factor
    Offer Sustainability
    Sustainable offer status
    Green Premium product
    REACh Regulation
    EU RoHS Directive
    Pro-active compliance (Product out of EU RoHS legal scope)
    EU RoHS Declaration
    Mercury free
    Yes
    RoHS exemption information
    China RoHS Regulation
    Environmental Disclosure
    Circularity Profile
    WEEE
    The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins
  • View more View less

    Documents

    Language
    • All Languages27
    • English27
    • French8
    Catalogue
    Format
    Size
    Date
    Add to My Documents
    prp.document.label.format pdf
    Size 12.7 MB
    Date 1/31/20
    prp.document.label.format pdf
    Size 14.5 MB
    Date 12/18/19
    User guide
    Format
    Size
    Date
    Add to My Documents
    Modicon M580 - Hot Standby, System Planning Guide for Frequently Used Architectures (Version 07)
    Description
    This document presents one of the PlantStruxure features, using Ethernet as the backbone around the Modicon M580 offer and connecting an M580 local rack and M580 RIO drops.This guide provides detailed information about the Modicon M580 Hot Standby system, in a simple daisy chain loop topology.
    prp.document.label.format pdf
    Size 16.4 MB
    Date 10/1/19
    Description
    This document presents one of the PlantStruxure features, using Ethernet as the backbone around the Modicon M580 offer and connecting an M580 local rack and M580 RIO drops.This guide provides detailed information about the Modicon M580 Hot Standby system, in a simple daisy chain loop topology.
    Modicon M580, Safety Manual (Version 05)
    Description
    This Safety Manual describes the modules of the M580 safety system with special regard as to how they meet the Safety requirements of the IEC 61508 standard. It provides detailed information on how to install, run, and maintain the system correctly in order to protect human beings as well as to prevent damage to environment, equipment, and production.
    prp.document.label.format pdf
    Size 12 MB
    Date 9/1/19
    Description
    This Safety Manual describes the modules of the M580 safety system with special regard as to how they meet the Safety requirements of the IEC 61508 standard. It provides detailed information on how to install, run, and maintain the system correctly in order to protect human beings as well as to prevent damage to environment, equipment, and production.
    Modicon M580, Safety System Planning Guide (Version 05)
    Description
    This Safety System Planning Guide describes the modules of the M580 Safety system with special regard to how they meet the Safety requirements of the IEC 61508. It provides detailed information on how to install, run, and maintain the system correctly in order to help protect human beings as well as to help prevent damage to environment, equipment, and production.
    prp.document.label.format pdf
    Size 7.9 MB
    Date 9/1/19
    Description
    This Safety System Planning Guide describes the modules of the M580 Safety system with special regard to how they meet the Safety requirements of the IEC 61508. It provides detailed information on how to install, run, and maintain the system correctly in order to help protect human beings as well as to help prevent damage to environment, equipment, and production.
    Modicon X80 - Racks and Power Supplies, Hardware Reference Manual (Version 03)
    Description
    This document provides detailed information about the Modicon X80 racks and power supplies used for M340 station, M580 system, and X80 drops.
    prp.document.label.format pdf
    Size 3 MB
    Date 12/1/18
    Description
    This document provides detailed information about the Modicon X80 racks and power supplies used for M340 station, M580 system, and X80 drops.
    Modicon M580 - System Planning Guide for Complex Topologies (Version 03)
    Description
    This document presents one of the PlantStruxure features, using Ethernet as the backbone around the Modicon M580 offer to facilitate communications between an M580 local rack and remote subrings through dual-ring switches (DRSs). This guide provides detailed information about planning complex M580 architectures, including these: - implementation of DRSs to support sub-rings - topology rules and recommendations for choosing a complex network configuration - system performance and limitations - system diagnostics
    prp.document.label.format pdf
    Size 3.7 MB
    Date 12/1/18
    Description
    This document presents one of the PlantStruxure features, using Ethernet as the backbone around the Modicon M580 offer to facilitate communications between an M580 local rack and remote subrings through dual-ring switches (DRSs). This guide provides detailed information about planning complex M580 architectures, including these: - implementation of DRSs to support sub-rings - topology rules and recommendations for choosing a complex network configuration - system performance and limitations - system diagnostics
    CAD
    Format
    Size
    Date
    Add to My Documents
    CAD file (on TraceParts) for BMXCPS4002: power supply module X80 - 100..240 V AC (Version 2.0)
    Description
    You will be redirected to the Traceparts website. Register for free or log in to your Traceparts account to download more than 15 different 2D or 3D CAD formats.
    CAD file (on TraceParts) for BMXCPS4002: power supply module X80 - 100..240 V AC (Version 2.0)
    Description
    You will be redirected to the Traceparts website. Register for free or log in to your Traceparts account to download more than 15 different 2D or 3D CAD formats.
    Certificate
    Format
    Size
    Date
    Add to My Documents
    UL E486184 - NRAQ-NRAQ7 (Version 1.0)
    Files in document
    Description
    UL certificate for USA and Canada
    prp.document.label.format zip
    Size 343.5 KB
    Date 12/17/19
    Files in document
    Description
    UL certificate for USA and Canada
    EAC - M340_M580_X80 (Version 1.0)
    Files in document
    Description
    Eurasian Conformity
    prp.document.label.format zip
    Size 2.2 MB
    Date 2/9/19
    Files in document
    Description
    Eurasian Conformity
    HazLoc by CSA - Class I Division 2 - M340_M580_X80 (Version 1.0)
    Description
    Hazardous location Class I Division 2 by CSA for US and Canada
    prp.document.label.format pdf
    Size 92.9 KB
    Date 1/23/19
    Description
    Hazardous location Class I Division 2 by CSA for US and Canada
    CSA 225844 - M340_M580_X80 (Version 1.0)
    Description
    Ordinary location by CSA for US and Canada
    prp.document.label.format pdf
    Size 242.2 KB
    Date 1/21/19
    Description
    Ordinary location by CSA for US and Canada
    Catalogue page
    Format
    Size
    Date
    Add to My Documents
    prp.document.label.format pdf
    Size 284 KB
    Date 12/18/19
    China RoHS declaration
    Format
    Size
    Date
    Add to My Documents
    BMXCPS4002 : BMXCPS4002_ROHS_CHINA_DECLARATION
    Description
    BMXCPS4002_ROHS_CHINA_DECLARATION
    prp.document.label.format pdf
    Size 195.3 KB
    Date 4/2/20
    Description
    BMXCPS4002_ROHS_CHINA_DECLARATION
    Declaration of conformity
    Format
    Size
    Date
    Add to My Documents
    RCM - M340_M580_X80 (Version 1.0)
    Description
    RCM
    prp.document.label.format pdf
    Size 238.3 KB
    Date 10/17/18
    Description
    RCM
    EU Declaration of Conformity - M340_M580_X80 (Version 1.0)
    Description
    EU Declaration of Conformity
    prp.document.label.format pdf
    Size 3.3 MB
    Date 9/4/18
    Description
    EU Declaration of Conformity
    End of Life Information
    Format
    Size
    Date
    Add to My Documents
    prp.document.label.format pdf
    Size 624.3 KB
    Date 10/1/17
    EU RoHS Declaration
    Format
    Size
    Date
    Add to My Documents
    BMXCPS4002 : BMXCPS4002_ROHS_DECLARATION
    Description
    BMXCPS4002_ROHS_DECLARATION
    prp.document.label.format pdf
    Size 195.3 KB
    Date 4/2/20
    Description
    BMXCPS4002_ROHS_DECLARATION
    Marine certificate
    Format
    Size
    Date
    Add to My Documents
    KRS Marine Certificate Modicon M340 X80 PLC (Version 1.0)
    Description
    Korean Register of Shipping
    prp.document.label.format pdf
    Size 563.2 KB
    Date 3/7/19
    Description
    Korean Register of Shipping
    NK Marine Certificate Modicon M340 M580 X80 PLCs (Version 1.0)
    Description
    ClassNK Marine Certificate Modicon M340-M580
    prp.document.label.format pdf
    Size 4.6 MB
    Date 2/18/19
    Description
    ClassNK Marine Certificate Modicon M340-M580
    prp.document.label.format pdf
    Size 317.6 KB
    Date 1/21/19
    Description
    Lloyds Register
    MERCHANT_NAVY_PLC_INSTALLATION (Version 1.0)
    Description
    Merchant navies Installation Instructions
    prp.document.label.format pdf
    Size 181.4 KB
    Date 1/11/19
    Description
    Merchant navies Installation Instructions
    BV Marine Certificate M340_M580_X80 PLCs (Version 1.0)
    Description
    Bureau Veritas - marine certificate for QUANTUM PLCs
    prp.document.label.format pdf
    Size 412.5 KB
    Date 1/7/19
    Description
    Bureau Veritas - marine certificate for QUANTUM PLCs
    RMRS_Marine Certificate_Modicon_M340_M580_X80_PLCs (Version 1.0)
    Description
    Russian Maritime Register of Shipping
    prp.document.label.format pdf
    Size 3 MB
    Date 5/18/18
    Description
    Russian Maritime Register of Shipping
    DNV-GL_Marine Certificate_Modicon_M340_M580_X80_PLCs (Version 1.0)
    Description
    Det Norske Veritas - Germanischer Lloyd
    prp.document.label.format pdf
    Size 205 KB
    Date 5/18/18
    Description
    Det Norske Veritas - Germanischer Lloyd
    Product Environmental Profile
    Format
    Size
    Date
    Add to My Documents
    prp.document.label.format pdf
    Size 407 KB
    Date 10/1/17
    REACh Declaration
    Format
    Size
    Date
    Add to My Documents
    BMXCPS4002 : BMXCPS4002_REACH_DECLARATION
    Description
    BMXCPS4002_REACH_DECLARATION
    prp.document.label.format pdf
    Size 195.3 KB
    Date 4/2/20
    Description
    BMXCPS4002_REACH_DECLARATION
  • View more View less

    Software and Firmware

    Language
    • English2
    Software - Updates
    Format
    Size
    Date
    Add to My Documents
    X80 REDUNDANT POWER SUPPLY PREDICTIVE MAINTENANCE LIBRARY (Version 1.0)
    Files in document
    7z
    2.6 KB
    7z
    2.8 KB
    pdf
    146.4 KB
    Description
    The power supply BMXCPS4002 is smart and embeds a secondary board allowing to gather advanced diagnostics that can be read by the M580 CPUs. The Predictive Maintenance Library contains function blocks that enable to retrieve information logged inside the power supply: - Global status of the pair of power supplies - Uptime durations and number of power cycles - Internal temperature - Total energy spend - Voltage thresholds monitoring (electrical grid quality) - Remaining life time estimation All these smart information allow the user to predict when it is time to replace the power supply before it fails. Refers to the user documentation for more details.
    prp.document.label.format zip
    Size 784.9 KB
    Date 1/30/18
    Files in document
    7z
    2.6 KB
    7z
    2.8 KB
    pdf
    146.4 KB
    Description
    The power supply BMXCPS4002 is smart and embeds a secondary board allowing to gather advanced diagnostics that can be read by the M580 CPUs. The Predictive Maintenance Library contains function blocks that enable to retrieve information logged inside the power supply: - Global status of the pair of power supplies - Uptime durations and number of power cycles - Internal temperature - Total energy spend - Voltage thresholds monitoring (electrical grid quality) - Remaining life time estimation All these smart information allow the user to predict when it is time to replace the power supply before it fails. Refers to the user documentation for more details.
    X80 REDUNDANT POWER SUPPLY PREDICTIVE MAINTENANCE LIBRARY VERSION HISTORY (Version V1.0)
    Files in document
    Description
    The power supply BMXCPS4002 is smart and embeds a secondary board allowing to gather advanced diagnostics that can be read by the M580 CPUs. The Predictive Maintenance Library contains function blocks that enable to retrieve information logged inside the power supply: - Global status of the pair of power supplies - Uptime durations and number of power cycles - Internal temperature - Total energy spend - Voltage thresholds monitoring (electrical grid quality) - Remaining life time estimation All these smart information allow the user to predict when it is time to replace the power supply before it fails. Refers to the user documentation for more details.
    prp.document.label.format zip
    Size 823.1 KB
    Date 10/7/16
    Files in document
    Description
    The power supply BMXCPS4002 is smart and embeds a secondary board allowing to gather advanced diagnostics that can be read by the M580 CPUs. The Predictive Maintenance Library contains function blocks that enable to retrieve information logged inside the power supply: - Global status of the pair of power supplies - Uptime durations and number of power cycles - Internal temperature - Total energy spend - Voltage thresholds monitoring (electrical grid quality) - Remaining life time estimation All these smart information allow the user to predict when it is time to replace the power supply before it fails. Refers to the user documentation for more details.
  • Technical FAQs

    No results found
    Unfortunately, related FAQs are unavailable due to temporary technical issues. Please try again later.