Welcome to the Schneider Electric Website

Welcome to our website.

Select your location

View all   Galaxy 5500
G55TUPSU60HB5S Product picture Schneider Electric

G55TUPSU60HB5S

G55TUPSU60HB5S Product picture Schneider Electric
G55TUPSU60HB5S

MGE Galaxy 5500 60KVA 400V Single UPS 5 Minutes, Start-up 5x8

Show more characteristics
The maximum number of products that can be compared is 4

  • Overview
    Description
    A versatile 3-phase UPS for facility, industrial and data center applications. Configurable system with a comprehensive range of accessories to meet your application demands.
    Model Name
    MGE Galaxy 5500 60KVA 400V Single UPS 5 Minutes, Start-up 5x8
    Includes
    Installation guide , User Manual
    Standard Lead Time
    Usually Ships within 2 Weeks
    Product Distribution
    Albania , Algeria , Andorra , Angola , Anguilla , Antigua And Barbuda , Argentina , Armenia , Aruba , Austria , Azerbaijan , Bahamas , Bahrain , Barbados , Belarus , Belgium , Belize , Benin , Bermuda , Bolivia , Bosnia And Herzegovina , Botswana , Brazil , Bulgaria , Burkina Faso , Burundi , Cameroon , Cayman Islands , Central African Republic , Chad , Chile , Congo , CONGO, THE DEMOCRATIC REPUBLIC OF THE , Costa Rica , Cote D'Ivoire , Croatia , Cuba , Cyprus , Czech Republic , Denmark , Djibouti , Dominica , Dominican Republic , Ecuador , Egypt , El Salvador , Equatorial Guinea , Eritrea , Estonia , Ethiopia , Falkland Islands (Malvinas) , Finland , France , Gabon , Gambia , Georgia , Germany , Ghana , Gibraltar , Greece , Grenada , Guadeloupe , Guatemala , Guinea , Guyana , French Guiana , Haiti , Honduras , Hungary , Iceland , Iran (Islamic Republic Of) , Iraq , Ireland , Israel , Italy , Jamaica , Jordan , Kazakhstan , Kenya , Kuwait , Latvia , Lebanon , Lesotho , Liberia , Liechtenstein , Lithuania , Luxembourg , Macedonia , Madagascar , Malawi , Mali , Malta , Martinique , Mauritania , Mauritius , Mayotte , Moldova, Republic Of , Mongolia , Morocco , Mozambique , Namibia , Netherlands , Netherlands Antilles , Nicaragua , Niger , Nigeria , Norway , Oman , Pakistan , Panama , Paraguay , Peru , Poland , Portugal , Puerto Rico , Reunion , Romania , Russian Federation , Rwanda , SAINT KITTS AND NEVIS , SAINT LUCIA , SAINT VINCENT AND THE GRENADINES , Saudi Arabia , Senegal , Sierra Leone , Slovakia (Slovak Republic) , Slovenia , Somalia , South Africa , Spain , Sudan , Suriname , Sweden , Switzerland , Tajikistan , TANZANIA, UNITED REPUBLIC OF , Togo , Trinidad And Tobago , Tunisia , Turkey , Turkmenistan , Turks And Caicos Islands , Uganda , Ukraine , United Arab Emirates , Uruguay , Uzbekistan , Venezuela , VIRGIN ISLANDS (UNITED STATES) , Western Sahara , Yemen , Zambia , Zimbabwe
    General
    Bypass Voltage Tolerance
    +/-10% settable from +/-4/6/8 and 10%
    Max Bypass Input Current
    87 A
    Output
    Output Power Capacity
    54.0 KW / 60.0 kVA
    Max Configurable Power (Watts)
    54.0 KW / 60.0 kVA
    Nominal Output Voltage
    400 3PH
    Output Voltage Note
    Configurable for 380 : 400 or 415 V 3 Phase nominal output voltage
    Output Voltage Distortion
    Less than 2%
    Output Frequency (sync to mains)
    50/60 Hz +/- 3 Hz user adjustable +/- 0.1
    Other Output Voltages
    380, 415V
    Crest Factor
    3 : 1
    Double Conversion Online
    Waveform Type
    Sine wave
    Output Connections
    (1) Hard Wire 4-wire (3PH + G) (Battery Backup)
    Output Voltage Tolerance
    +/-1% static and +/- 5% at 100% load step
    Output Voltage THD
    < 1% linear load and < 2.5% nonlinear load
    Overload Operation
    10 minutes @ 125% and 60 seconds @ 150%
    Required Output Current Protection
    87 A
    Bypass
    Built-in Maintenance Bypass , Built-in Static Bypass , Optional External Bypass
    Input
    Nominal Input Voltage
    400 3PH
    Input Frequency
    45 - 65 Hz
    Input Connections
    Hard Wire 4-wire (3PH + G) , Hard Wire 4-wire (3PH + N)
    Input voltage range for main operations
    323 - 437 (380V) V , 340 - 460 (400V) V , 353 - 477 (415V) V
    Input voltage adjustable range for mains operation
    250 - 470V
    Other Input Voltages
    380 , 415
    Maximum Input Current
    88 A
    Input Breaker Capacity
    125 A
    Maximum Short Circuit Withstand (Icw)
    20.0
    Input Total Harmonic Distortion
    Less than 3% for full load
    Type of Input Protection Required
    3-pole breaker
    Batteries & Runtime
    Battery Type
    VRLA
    Typical recharge time
    10 hour(s)
    Nominal Battery Voltage
    432V
    Communications & Management
    Available SmartSlot™ Interface Quantity
    2
    Pre-Installed SmartSlot™ Cards
    AP9635
    Control panel
    Multi-function LCD status and control console
    Emergency Power Off (EPO)
    Yes
    Physical
    Maximum Height
    1900.0 mm
    Maximum Width
    1112.0 mm
    Maximum Depth
    850.0 mm
    Net Weight
    975.0 kg
    Shipping Height
    2030.0 mm
    Shipping Width
    1200.0 mm
    Shipping Depth
    960.0 mm
    Environmental
    Operating Environment
    0 - 40 °C
    Operating Relative Humidity
    0 - 95 %
    Operating Elevation
    0-999.9 meters
    Storage Temperature
    -20 - 45 °C
    Storage Relative Humidity
    0 - 95 %
    Storage Elevation
    0-12000 meters
    Audible noise at 1 meter from surface of unit
    61.400 dB
    Conformance
    Approvals
    CE , EN/IEC 62040-3 , IEC 62040-1-2 , IEC 62040-2 , ISO 9001 , TUV , VDE
    Standard warranty
    1 year (parts only) , 1 year on-site repair or replace with factory authorized Start-Up
  • View more View less

    Documents

    Language
    • All Languages16
    • English15
    • Arabic1
    Catalogue
    Format
    Size
    Date
    Add to My Documents
    Galaxy 5500 Technical Brochure (Version V2)
    Files in document
    pdf
    989.7 KB
    Description
    Brochure for the MGE Galaxy 5500 Feature and benefits
    prp.document.label.format zip
    Size 6.4 MB
    Date 8/1/12
    Files in document
    pdf
    989.7 KB
    Description
    Brochure for the MGE Galaxy 5500 Feature and benefits
    User guide
    Format
    Size
    Date
    Add to My Documents
    Galaxy 5500 20 - 120 kVA 400 V Installation (Version V3)
    Description
    Providing the certified electrician with information on how to install and connect the Galaxy 5500 UPS
    prp.document.label.format pdf
    Size 7.1 MB
    Date 6/17/18
    Description
    Providing the certified electrician with information on how to install and connect the Galaxy 5500 UPS
    Galaxy 5500 20 - 120 kVA 400 V receiving and unpacking (Version V2)
    Description
    Providing information on storage conditions and how to unpack theGalaxy 5500 400 V cabinets and remove them from the pallet
    prp.document.label.format pdf
    Size 3.5 MB
    Date 5/4/16
    Description
    Providing information on storage conditions and how to unpack theGalaxy 5500 400 V cabinets and remove them from the pallet
    Galaxy 5000/5500 40-130 kVA 480 V and 20-120 kVA 400 V Operation Manual (Version V0)
    Description
    Operation Manual containing information on operation, maintenance and troubleshooting for the user of the Galaxy 5000/5500 system
    prp.document.label.format pdf
    Size 3.7 MB
    Date 4/25/16
    Description
    Operation Manual containing information on operation, maintenance and troubleshooting for the user of the Galaxy 5000/5500 system
    MGE Galaxy 5500 20-120 kVA 400 V Safety and Handling (Version V0)
    Description
    Providing information on handling safety, operating environment, electrical safety, battery safety, battery storage time and regulatory agency approval
    prp.document.label.format pdf
    Size 433.9 KB
    Date 12/8/14
    Description
    Providing information on handling safety, operating environment, electrical safety, battery safety, battery storage time and regulatory agency approval
    Schneider Electric Important Safety Instructions (Version V0)
    Description
    Schneider Electric Important Safety Instructions in English, Chinese Simplified, French, German, European Spanish, Italian, Russian, Portuguese Brazilian, Dutch, Japanese and Korean
    prp.document.label.format pdf
    Size 1.1 MB
    Date 6/6/14
    Description
    Schneider Electric Important Safety Instructions in English, Chinese Simplified, French, German, European Spanish, Italian, Russian, Portuguese Brazilian, Dutch, Japanese and Korean
    Modbus Register Map for TCP IP- MGE Galaxy 5500 (Version V0)
    Files in document
    pdf
    38.6 KB
    pdf
    38.6 KB
    Description
    Documents the register values for the Modbus TCP IP implementation on the MGE Galaxy 5500
    prp.document.label.format zip
    Size 77.2 KB
    Date 5/29/14
    Files in document
    pdf
    38.6 KB
    pdf
    38.6 KB
    Description
    Documents the register values for the Modbus TCP IP implementation on the MGE Galaxy 5500
    prp.document.label.format pdf
    Size 959 KB
    Date 12/8/14
    CAD
    Format
    Size
    Date
    Add to My Documents
    G55TUPSU20K60H - MGE Galaxy 5500 Unitary UPS 20-60kVA with Internal Batteries (Version V3)
    Files in document
    Description
    MGE Galaxy 5500, Mechanicals
    prp.document.label.format zip
    Size 11.4 MB
    Date 1/16/18
    Files in document
    Description
    MGE Galaxy 5500, Mechanicals
    G55T20K60HAIOBOTC1-SD – MGE Galaxy 5500 20-60kVA UPS with Intl Battery 1MOD with Output XFMR System One Line (Version V0)
    Files in document
    zip
    169.1 KB
    pdf
    340.4 KB
    Description
    MGE Galaxy 5500, System One Line Diagrams
    prp.document.label.format zip
    Size 509.5 KB
    Date 7/5/12
    Files in document
    zip
    169.1 KB
    pdf
    340.4 KB
    Description
    MGE Galaxy 5500, System One Line Diagrams
    G55T20K60HAIOBC1-SD – MGE Galaxy 5500 20-60kVA UPS with Internal Battery 1MOD System One Line (Version V0)
    Files in document
    pdf
    334.1 KB
    zip
    165.5 KB
    Description
    MGE Galaxy 5500, System One Line Diagrams
    prp.document.label.format zip
    Size 499.6 KB
    Date 7/5/12
    Files in document
    pdf
    334.1 KB
    zip
    165.5 KB
    Description
    MGE Galaxy 5500, System One Line Diagrams
    Specification guide
    Format
    Size
    Date
    Add to My Documents
    MGE Galaxy 5500 20-120 kVA 400 V Technical Specifications (Version V2)
    Description
    Providing information on technical data, facility planning, drawings, and options
    prp.document.label.format pdf
    Size 3.9 MB
    Date 5/19/16
    Description
    Providing information on technical data, facility planning, drawings, and options
    Certificate
    Format
    Size
    Date
    Add to My Documents
    MGE Galaxy 5500 - CB-TUV certificate (Version V0)
    Description
    CB certificate for sales
    prp.document.label.format pdf
    Size 1.4 MB
    Date 3/19/13
    Description
    CB certificate for sales
    prp.document.label.format pdf
    Size 149.7 KB
    Date 10/16/12
    Description
    CE Declaration of Conformity
    Specification for tender
    Format
    Size
    Date
    Add to My Documents
    CSI 2004/1995 MGE Galaxy 5500 400 V Single System (Version V0)
    Files in document
    pdf
    140 KB
    zip
    47.4 KB
    Description
    Guide Specifications
    prp.document.label.format zip
    Size 187.4 KB
    Date 8/1/12
    Files in document
    pdf
    140 KB
    zip
    47.4 KB
    Description
    Guide Specifications
    CSI 2004/1995 MGE Galaxy 5500 400 V Parallel System (Version V1)
    Files in document
    pdf
    143.5 KB
    zip
    53.1 KB
    Description
    Guide Specifications
    prp.document.label.format zip
    Size 196.6 KB
    Date 7/24/12
    Files in document
    pdf
    143.5 KB
    zip
    53.1 KB
    Description
    Guide Specifications
  • Technical FAQs

    No results found
    Unfortunately, related FAQs are unavailable due to temporary technical issues. Please try again later.