Welcome to the Schneider Electric Website

Welcome to our website.

Select your location

View all   TeSys GV2
GV2RT14 Product picture Schneider Electric

GV2RT14

Green premium brand logo
GV2RT14 Product picture Schneider Electric
GV2RT14
Green premium brand logo

Motor circuit breaker, TeSys GV2, 3P, 6-10 A, thermal magnetic, screw clamp terminals

Show more characteristics
The maximum number of products that can be compared is 4

  • Main
    range
    TeSys
    product name
    TeSys GV2
    device short name
    GV2RT
    device application
    Transformer
    Motor
    trip unit technology
    Thermal-magnetic
    Complementary
    poles description
    3P
    network type
    AC
    utilisation category
    AC-3 conforming to IEC 60947-4-1
    Category A conforming to IEC 60947-2
    network frequency
    50/60 Hz conforming to IEC 60947-4-1
    fixing mode
    35 mm symmetrical DIN rail: clipped
    Panel: screwed (with adaptor plate)
    operating position
    Any position
    motor power kW
    1.5 kW at 220/230 V AC 50/60 Hz motor protection high peak current
    2.2 kW at 220/230 V AC 50/60 Hz motor protection high peak current
    3 kW at 400/415 V AC 50/60 Hz motor protection high peak current
    4 kW at 400/415 V AC 50/60 Hz motor protection high peak current
    4 kW at 440 V AC 50/60 Hz motor protection high peak current
    4 kW at 500 V AC 50/60 Hz motor protection high peak current
    5.5 kW at 500 V AC 50/60 Hz motor protection high peak current
    5.5 kW at 690 V AC 50/60 Hz motor protection high peak current
    7.5 kW at 690 V AC 50/60 Hz motor protection high peak current
    2.5 kW at 230/240 V AC 50/60 Hz transformer protection
    4 kW at 400/415 V AC 50/60 Hz transformer protection
    5 kW at 400/415 V AC 50/60 Hz transformer protection
    5 kW at 440 V AC 50/60 Hz transformer protection
    5 kW at 500 V AC 50/60 Hz transformer protection
    6.3 kW at 500 V AC 50/60 Hz transformer protection
    breaking capacity
    100 kA Icu at 400/415 V AC 50/60 Hz conforming to IEC 60947-2
    3 kA Icu at 690 V AC 50/60 Hz conforming to IEC 60947-2
    10 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2
    15 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2
    100 kA Icu at 220/230 V AC 50/60 Hz conforming to IEC 60947-2
    control type
    Toggle
    [In] rated current
    10 A
    thermal protection adjustment range
    6…10 A
    magnetic tripping current
    200 A
    [Ue] rated operational voltage
    690 V AC 50/60 Hz conforming to IEC 60947-2
    [Ui] rated insulation voltage
    690 V AC 50/60 Hz conforming to IEC 60947-2
    [Ith] conventional free air thermal current
    10 A conforming to IEC 60947-4-1
    [Uimp] rated impulse withstand voltage
    IEC 60947-2 6 kV
    power dissipation per pole
    2.5 W
    mechanical durability
    100000 cycles
    electrical durability
    100000 cycles for AC-3 at 440 V
    maximum operating rate
    25 cyc/h
    rated duty
    Continuous conforming to IEC 60947-4-1
    connections - terminals
    Screw clamp terminals 2 cable(s) 1…6 mm² solid
    Screw clamp terminals 2 cable(s) 1.5…6 mm² flexible without cable end
    Screw clamp terminals 2 cable(s) 1…4 mm² flexible with cable end
    tightening torque
    1.7 N.m on screw clamp terminals
    suitability for isolation
    Yes conforming to IEC 60947-1
    height
    89 mm
    width
    45 mm
    depth
    78.5 mm
    Environment
    standards
    EN/IEC 60947-2
    EN/IEC 60947-4-1
    UL 60947-4-1
    CSA C22.2 No 60947-4-1
    product certifications
    IECEE CB Scheme
    UL
    CSA
    CCC
    EAC
    BV
    LROS (Lloyds register of shipping)
    protective treatment
    TH
    IP degree of protection
    IP20 conforming to IEC 60529
    IK degree of protection
    IK04
    ambient air temperature for operation
    -20…60 °C
    ambient air temperature for storage
    -40…80 °C
    fire resistance
    960 °C conforming to IEC 60695-2-1
    operating altitude
    2000 m
    Offer Sustainability
    Sustainable offer status
    Green Premium product
    REACh Regulation
    EU RoHS Directive
    Mercury free
    Yes
    RoHS exemption information
    China RoHS Regulation
    China RoHS declaration
    Product out of China RoHS scope. Substance declaration for your information
    Environmental Disclosure
    WEEE
    The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins
    Contractual warranty
    Warranty
    18 months
  • View more View less

    Documents

    Language
    • English11
    Catalogue
    Format
    Size
    Date
    Add to My Documents
    Tesys catalogue 2019 - 2020 Motor control and protection components (Version 9.2)
    Description
    Ready-to-use motor starters and all components for building specific motor starters ( circuit breakers, contactors, overload relays , accessories ...).The catalogue can also be downloaded chapter per chapter.
    prp.document.label.format pdf
    Size 111.5 MB
    Date 7/12/19
    Description
    Ready-to-use motor starters and all components for building specific motor starters ( circuit breakers, contactors, overload relays , accessories ...).The catalogue can also be downloaded chapter per chapter.
    CAD
    Format
    Size
    Date
    Add to My Documents
    CAD file (on TraceParts) for GV2RT14: TeSys GV2-Circuit breaker-thermal-magnetic - 6.3…10 A - screw clamp terminals (Version 3.0)
    Description
    You will be redirected to the Traceparts website. Register for free or log in to your Traceparts account to download more than 15 different 2D or 3D CAD formats.
    CAD file (on TraceParts) for GV2RT14: TeSys GV2-Circuit breaker-thermal-magnetic - 6.3…10 A - screw clamp terminals (Version 3.0)
    Description
    You will be redirected to the Traceparts website. Register for free or log in to your Traceparts account to download more than 15 different 2D or 3D CAD formats.
    GV2 MOTOR CB MAGNETIC TOGGLE SWITCH (Version 1.0)
    Files in document
    pdf
    248.9 KB
    stp
    458.1 KB
    zip
    679.2 KB
    prp.document.label.format zip
    Size 1.4 MB
    Date 9/24/18
    Files in document
    pdf
    248.9 KB
    stp
    458.1 KB
    zip
    679.2 KB
    Certificate
    Format
    Size
    Date
    Add to My Documents
    prp.document.label.format pdf
    Size 2.5 MB
    Date 11/23/15
    prp.document.label.format pdf
    Size 466.4 KB
    Date 4/1/15
    Instruction sheet
    Format
    Size
    Date
    Add to My Documents
    prp.document.label.format pdf
    Size 703.4 KB
    Date 4/1/16
    prp.document.label.format pdf
    Size 8.9 MB
    Date 6/1/16
    China RoHS declaration
    Format
    Size
    Date
    Add to My Documents
    GV2RT14 : Motor circuit breaker, TeSys GV2, 3P, 6-10 A, thermal magnetic, screw clamp terminals
    Description
    Motor circuit breaker, TeSys GV2, 3P, 6-10 A, thermal magnetic, screw clamp terminals
    prp.document.label.format pdf
    Size 195.3 KB
    Date 4/1/20
    Description
    Motor circuit breaker, TeSys GV2, 3P, 6-10 A, thermal magnetic, screw clamp terminals
    EU RoHS Declaration
    Format
    Size
    Date
    Add to My Documents
    GV2RT14 : Motor circuit breaker, TeSys GV2, 3P, 6-10 A, thermal magnetic, screw clamp terminals
    Description
    Motor circuit breaker, TeSys GV2, 3P, 6-10 A, thermal magnetic, screw clamp terminals
    prp.document.label.format pdf
    Size 195.3 KB
    Date 4/1/20
    Description
    Motor circuit breaker, TeSys GV2, 3P, 6-10 A, thermal magnetic, screw clamp terminals
    Product Environmental Profile
    Format
    Size
    Date
    Add to My Documents
    prp.document.label.format pdf
    Size 150.1 KB
    Date 8/14/16
    REACh Declaration
    Format
    Size
    Date
    Add to My Documents
    GV2RT14 : Motor circuit breaker, TeSys GV2, 3P, 6-10 A, thermal magnetic, screw clamp terminals
    Description
    Motor circuit breaker, TeSys GV2, 3P, 6-10 A, thermal magnetic, screw clamp terminals
    prp.document.label.format pdf
    Size 195.3 KB
    Date 4/1/20
    Description
    Motor circuit breaker, TeSys GV2, 3P, 6-10 A, thermal magnetic, screw clamp terminals
  • Technical FAQs

    No results found
    Unfortunately, related FAQs are unavailable due to temporary technical issues. Please try again later.
  • Dimensions Drawings

    GV2RT

    Dimensions


    X1: Electrical clearance = 40 mm for Ue < 690 V

    Mounting

    Mounting of external operator GV2AP03


    On 35 mm rail


    c = 80 on AM1 DP200 (35 x 7.5)

    c = 88 on AM1 DE200, ED200 (35 x 15)

    On panel with adapter plate GV2AF02


    On pre-slotted plate AM1 PA


    On rails DZ5 MB



  • Connections and Schema

    GV2ME•• and GV2RT



Compare products: /