Welcome to the Schneider Electric Website

Welcome to our website.

Select your location

View all   TeSys F
LC1F780 Product picture Schneider Electric

LC1F780

Green premium brand logo
LC1F780 Product picture Schneider Electric
LC1F780
Green premium brand logo

TeSys F contactor - 3P(3 NO)-AC-3 <= 440V 780 A with coil LX1/ LX9 - 110…500V AC 40/400Hz, LX4 - 110...440V DC

Show more characteristics
The maximum number of products that can be compared is 4

  • Main
    range
    TeSys
    product name
    TeSys F
    product or component type
    Contactor
    device short name
    LC1F
    contactor application
    Resistive load
    Motor control
    utilisation category
    AC-4
    AC-3
    AC-1
    poles description
    3P
    power pole contact composition
    3 NO
    [Ue] rated operational voltage
    <= 1000 V AC 50/60 Hz
    <= 460 V DC
    [Ie] rated operational current
    780 A (at <55 °C) at <= 440 V AC AC-3
    1600 A (at <40 °C) at <= 440 V AC AC-1
    motor power kW
    450 kW at 1000 V AC 50/60 Hz (AC-3)
    400 kW at 380...400 V AC 50/60 Hz (AC-3)
    425 kW at 415 V AC 50/60 Hz (AC-3)
    425 kW at 440 V AC 50/60 Hz (AC-3)
    450 kW at 500 V AC 50/60 Hz (AC-3)
    220 kW at 220...240 V AC 50/60 Hz (AC-3)
    475 kW at 660...690 V AC 50/60 Hz (AC-3)
    110 kW at 400 V AC 50/60 Hz (AC-4)
    Complementary
    [Uc] control circuit voltage
    110...500 V AC 40...400 Hz with LX1/LX9 coil
    48...440 V DC with LX4 coil
    [Uimp] rated impulse withstand voltage
    8 kV
    overvoltage category
    III
    [Ith] conventional free air thermal current
    1600 A (at 40 °C)
    Irms rated making capacity
    7800 A AC conforming to IEC 60947-4-1
    rated breaking capacity
    6240 A conforming to IEC 60947-4-1
    [Icw] rated short-time withstand current
    3000 A 40 °C - 3 min
    6250 A 40 °C - 10 s
    5600 A 40 °C - 30 s
    4600 A 40 °C - 1 min
    2200 A 40 °C - 10 min
    associated fuse rating
    800 A aM at <= 440 V
    1600 A gG at <= 440 V
    average impedance
    0.1 mOhm - Ith 1600 A 50 Hz
    [Ui] rated insulation voltage
    1000 V conforming to IEC 60947-4-1
    1500 V conforming to VDE 0110 group C
    power dissipation per pole
    60 W AC-3
    250 W AC-1
    control circuit voltage limits
    Operational: 0.85...1.1 Uc AC 40...400 Hz with LX1/LX9 coil
    Drop-out: 0.2...0.4 Uc AC 40...400 Hz with LX1/LX9 coil
    Operational: 0.85...1.1 Uc DC with LX4 coil
    Drop-out: 0.2...0.4 Uc DC with LX4 coil
    heat dissipation
    22 W
    operating time
    40...80 ms closing for with LX1/LX9 coil
    130...230 ms opening for with LX1/LX9 coil
    70...80 ms closing for with LX4 coil
    100...130 ms opening for with LX4 coil
    mounting support
    Plate
    standards
    IEC 60947-1
    IEC 60947-4-1
    EN 60947-1
    JIS C8201-4-1
    EN 60947-4-1
    product certifications
    UL
    LROS (Lloyds register of shipping)
    RINA
    DNV
    CCC
    BV
    CB
    ABS
    connections - terminals
    Power circuit: bar 2 cable(s) - busbar cross section: 100 x 5 mm
    Power circuit: bolted connection
    Control circuit: screw clamp terminals 1 cable(s) 1…4 mm²flexible without cable end
    Control circuit: screw clamp terminals 2 cable(s) 1…4 mm²flexible with cable end
    Control circuit: screw clamp terminals 1 cable(s) 1…4 mm²flexible with cable end
    Control circuit: screw clamp terminals 2 cable(s) 1…2.5 mm²solid without cable end
    Control circuit: screw clamp terminals 1 cable(s) 1…4 mm²
    Control circuit: screw clamp terminals 2 cable(s) 1…4 mm²
    tightening torque
    Power circuit: 58 N.m
    Control circuit: 1.2 N.m
    mechanical durability
    5 Mcycles
    inrush power in VA
    1900…2300 VA, 40...400 Hz cos phi 0.9 (at 20 °C)with LX1/LX9 coil
    1960…2420 VA (at 20 °C)with LX4 coil
    hold-in power consumption in VA
    44…55 VA, 40...400 Hz cos phi 0.9 (at 20 °C)with LX1/LX9 coil
    42…52 VA (at 20 °C)with LX4 coil
    maximum operating rate
    600 cyc/h 55 °C
    compatibility code
    LC1F
    Environment
    IP degree of protection
    IP20 front face with shrouds conforming to IEC 60529
    IP20 front face with shrouds conforming to VDE 0106
    protective treatment
    TH
    ambient air temperature for operation
    -5…55 °C
    ambient air temperature for storage
    -60…80 °C
    permissible ambient air temperature around the device
    -40…70 °C
    mechanical robustness
    Vibrations contactor open: 2.5 Gn, 5...300 Hz
    Vibrations contactor closed: 5.5 Gn, 5...300 Hz
    Shocks contactor open: 5 Gn for 1/2 sine wave (11 ms)
    Shocks contactor closed: 15 Gn for 1/2 sine wave (11 ms)
    height
    434 mm
    width
    702 mm
    depth
    255 mm
    net weight
    48 kg
    Offer Sustainability
    Sustainable offer status
    Green Premium product
    REACh Regulation
    EU RoHS Directive
    Mercury free
    Yes
    RoHS exemption information
    China RoHS Regulation
    China RoHS declaration
    Product out of China RoHS scope. Substance declaration for your information
    Environmental Disclosure
    Circularity Profile
    WEEE
    The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins
    Contractual warranty
    Warranty
    18 months
  • View more View less

    Documents

    Language
    • All Languages18
    • English18
    • Chinese7
    • French9
    • German7
    • Italian7
    • Portuguese7
    • Russian7
    • Spanish7
    Catalogue
    Format
    Size
    Date
    Add to My Documents
    Tesys catalogue 2019 - 2020 Motor control and protection components (Version 9.2)
    Description
    Ready-to-use motor starters and all components for building specific motor starters ( circuit breakers, contactors, overload relays , accessories ...).The catalogue can also be downloaded chapter per chapter.
    prp.document.label.format pdf
    Size 111.5 MB
    Date 7/12/19
    Description
    Ready-to-use motor starters and all components for building specific motor starters ( circuit breakers, contactors, overload relays , accessories ...).The catalogue can also be downloaded chapter per chapter.
    CAD
    Format
    Size
    Date
    Add to My Documents
    CAD file (on TraceParts) for LC1F780: TeSys F contactor - 3P(3 NO) - AC-3 - <= 440 V 780 A - without coil (Version 2.0)
    Description
    You will be redirected to the Traceparts website. Register for free or log in to your Traceparts account to download more than 15 different 2D or 3D CAD formats.
    CAD file (on TraceParts) for LC1F780: TeSys F contactor - 3P(3 NO) - AC-3 - <= 440 V 780 A - without coil (Version 2.0)
    Description
    You will be redirected to the Traceparts website. Register for free or log in to your Traceparts account to download more than 15 different 2D or 3D CAD formats.
    prp.document.label.format zip
    Size 1.8 MB
    Date 2/26/18
    Files in document
    stp
    1.3 MB
    pdf
    573.4 KB
    prp.document.label.format zip
    Size 985.2 KB
    Date 8/3/06
    prp.document.label.format zip
    Size 197.3 KB
    Date 8/3/06
    Brochure
    Format
    Size
    Date
    Add to My Documents
    prp.document.label.format zip
    Size 825.6 MB
    Date 11/26/15
    Certificate
    Format
    Size
    Date
    Add to My Documents
    prp.document.label.format pdf
    Size 105.6 KB
    Date 7/30/14
    prp.document.label.format pdf
    Size 1.8 MB
    Date 4/17/17
    Instruction sheet
    Format
    Size
    Date
    Add to My Documents
    prp.document.label.format pdf
    Size 6 MB
    Date 1/2/19
    prp.document.label.format pdf
    Size 6.5 MB
    Date 2/2/15
    China RoHS declaration
    Format
    Size
    Date
    Add to My Documents
    LC1F780 : TeSys F contactor - 3P(3 NO) - AC-3 - <= 440 V 780 A - without coil
    Description
    TeSys F contactor - 3P(3 NO) - AC-3 - <= 440 V 780 A - without coil
    prp.document.label.format pdf
    Size 195.3 KB
    Date 4/4/20
    Description
    TeSys F contactor - 3P(3 NO) - AC-3 - <= 440 V 780 A - without coil
    Declaration of conformity
    Format
    Size
    Date
    Add to My Documents
    prp.document.label.format pdf
    Size 301.8 KB
    Date 7/4/19
    End of Life Information
    Format
    Size
    Date
    Add to My Documents
    prp.document.label.format pdf
    Size 391.6 KB
    Date 12/18/18
    TeSys LC1 F330-1250 - EoLi (Version 1.0)
    Description
    TeSys LC1 F330-1250 - EoLi
    prp.document.label.format pdf
    Size 200.1 KB
    Date 7/1/15
    Description
    TeSys LC1 F330-1250 - EoLi
    EU RoHS Declaration
    Format
    Size
    Date
    Add to My Documents
    LC1F780 : TeSys F contactor - 3P(3 NO) - AC-3 - <= 440 V 780 A - without coil
    Description
    TeSys F contactor - 3P(3 NO) - AC-3 - <= 440 V 780 A - without coil
    prp.document.label.format pdf
    Size 195.3 KB
    Date 4/4/20
    Description
    TeSys F contactor - 3P(3 NO) - AC-3 - <= 440 V 780 A - without coil
    Presentation
    Format
    Size
    Date
    Add to My Documents
    prp.document.label.format pptx
    Size 5.4 MB
    Date 11/25/15
    Product Environmental Profile
    Format
    Size
    Date
    Add to My Documents
    TeSys LC1F330-1250 - PEP (Version 1.0)
    Description
    TeSys LC1F330-1250 - PEP
    prp.document.label.format pdf
    Size 202.6 KB
    Date 7/1/15
    Description
    TeSys LC1F330-1250 - PEP
    REACh Declaration
    Format
    Size
    Date
    Add to My Documents
    LC1F780 : TeSys F contactor - 3P(3 NO) - AC-3 - <= 440 V 780 A - without coil
    Description
    TeSys F contactor - 3P(3 NO) - AC-3 - <= 440 V 780 A - without coil
    prp.document.label.format pdf
    Size 195.3 KB
    Date 4/4/20
    Description
    TeSys F contactor - 3P(3 NO) - AC-3 - <= 440 V 780 A - without coil
  • Technical FAQs