View all   EasyPact TVS thermal overload relay
LRE363 Product picture Schneider Electric

LRE363

LRE363 Product picture Schneider Electric
LRE363

EasyPact TVS differential thermal overload relay 63...80 A - class 10A

Show more characteristics
The maximum number of products that can be compared is 4. Remove already added products.

  • Main
    range
    EasyPact
    product name
    EasyPact TVS
    product or component type
    Differential thermal overload relay
    device short name
    LRE
    relay application
    Motor protection
    phase failure sensitivity
    Tripping current 130 % of Ir on two phase, the last one at 0 conforming to IEC 60947-4-1
    Complementary
    product compatibility
    LC1E80...95
    network type
    AC
    network frequency
    50...60 Hz
    mounting support
    Under contactor
    Plate, with specific accessories
    Rail, with specific accessories
    thermal overload class
    Class 10A conforming to IEC 60947-4-1
    signalling function
    Relay trip indicator
    thermal protection adjustment range
    63…80 A
    tripping threshold
    1.14 +/- 0.06 Ir conforming to IEC 60947-4-1
    mechanical robustness
    Shocks: 6 Gn for 11 ms conforming to IEC 60068-2-7
    Vibrations: 3 Gn conforming to IEC 60068-2-6
    auxiliary contact composition
    1 NO + 1 NC
    [Ith] conventional free air thermal current
    5 A for signalling circuit
    [Ue] rated operational voltage
    <= 690 V AC
    associated fuse rating
    125 A gG for power circuit
    80 A aM for power circuit
    5 A gG for signalling circuit
    [Ui] rated insulation voltage
    690 V conforming to IEC 60947-4-1
    [Uimp] rated impulse withstand voltage
    6 kV
    local signalling
    Trip indicator
    control type
    Push-button red stop:
    Push-button green reset:
    temperature compensation
    -20…60 °C
    connections - terminals
    Signalling circuit: screw clamp terminals 2 1…2.5 mm² - cable stiffness: flexible without cable end
    Signalling circuit: screw clamp terminals 2 1…2.5 mm² - cable stiffness: flexible with cable end
    Signalling circuit: screw clamp terminals 2 1…2.5 mm² - cable stiffness: solid without cable end
    Power circuit: screw clamp terminals 1 4…35 mm² - cable stiffness: flexible without cable end
    Power circuit: screw clamp terminals 1 4…35 mm² - cable stiffness: flexible with cable end
    Power circuit: screw clamp terminals 1 4…35 mm² - cable stiffness: solid without cable end
    tightening torque
    Power circuit: 9 N.m - on screw clamp terminals
    Signalling circuit: 1.7 N.m - on screw clamp terminals
    height
    54 mm
    width
    70 mm
    depth
    113 mm
    net weight
    0.48 kg
    Environment
    standards
    IEC 60947-4-1
    IEC 60947-5-1
    product certifications
    GOST
    protective treatment
    TH conforming to IEC 60068
    IP degree of protection
    IP20 conforming to IEC 60529
    ambient air temperature for operation
    -20…60 °C without derating conforming to IEC 60947-4-1
    -20…70 °C with derating
    ambient air temperature for storage
    -60…80 °C
    fire resistance
    850 °C conforming to IEC 60068-2-1
    dielectric strength
    6 kV at 50 Hz conforming to IEC 60255-5
    electromagnetic compatibility
    Surge withstand: 6 kV conforming to IEC 60801-5
    Offer Sustainability
    REACh Regulation
    REACh free of SVHC
    Yes
    EU RoHS Directive
    Mercury free
    Yes
    RoHS exemption information
    China RoHS Regulation
    China RoHS declaration
    Product out of China RoHS scope. Substance declaration for your information
    WEEE
    The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins
    Contractual warranty
    Warranty
    18 months
  • View more View less

    Documents

    Language
    • All Languages9
    • English9
    • French3
    CAD
    Format
    Size
    Date
    Add to My Documents
    Certificate
    Format
    Size
    Date
    Add to My Documents
    prp.document.label.format pdf
    Size 428.9 KB
    Date 1/18/18
    China RoHS declaration
    Format
    Size
    Date
    Add to My Documents
    LRE363 : EasyPact TVS differential thermal overload relay 63...80 A - class 10A
    Description
    EasyPact TVS differential thermal overload relay 63...80 A - class 10A
    prp.document.label.format pdf
    Size 195.3 KB
    Date 5/29/20
    Description
    EasyPact TVS differential thermal overload relay 63...80 A - class 10A
    Declaration of conformity
    Format
    Size
    Date
    Add to My Documents
    prp.document.label.format pdf
    Size 272 KB
    Date 7/3/19
    End of Life Information
    Format
    Size
    Date
    Add to My Documents
    TeSys D Contactors AC 09 to 18A (Version 2.0)
    Description
    TeSys D Contactors AC 09 to 18A
    prp.document.label.format pdf
    Size 157.9 KB
    Date 4/28/16
    Description
    TeSys D Contactors AC 09 to 18A
    EU RoHS Declaration
    Format
    Size
    Date
    Add to My Documents
    LRE363 : EasyPact TVS differential thermal overload relay 63...80 A - class 10A
    Description
    EasyPact TVS differential thermal overload relay 63...80 A - class 10A
    prp.document.label.format pdf
    Size 195.3 KB
    Date 5/29/20
    Description
    EasyPact TVS differential thermal overload relay 63...80 A - class 10A
    Product Environmental Profile
    Format
    Size
    Date
    Add to My Documents
    3P CONT 9A AC3 4KW 1NO 1NC 230VAC COIL (Version 3.0)
    Description
    3P CONT 9A AC3 4KW 1NO 1NC 230VAC COIL
    prp.document.label.format pdf
    Size 132 KB
    Date 4/28/16
    Description
    3P CONT 9A AC3 4KW 1NO 1NC 230VAC COIL
    REACh Declaration
    Format
    Size
    Date
    Add to My Documents
    LRE363 : EasyPact TVS differential thermal overload relay 63...80 A - class 10A
    Description
    EasyPact TVS differential thermal overload relay 63...80 A - class 10A
    prp.document.label.format pdf
    Size 195.3 KB
    Date 5/29/20
    Description
    EasyPact TVS differential thermal overload relay 63...80 A - class 10A
  • Technical FAQs

    No results found
    Unfortunately, related FAQs are unavailable due to temporary technical issues. Please try again later.
Compare products: /