Welcome to the Schneider Electric Website

Welcome to our website.

Select your location

View all   Modicon Premium
TSXCTY2AC Product picture Schneider Electric

TSXCTY2AC

TSXCTY2AC Product picture Schneider Electric
TSXCTY2AC

2 channels counter modules - 40 kHz - 30 mA at 24 V DC, 280 mA at 5 V DC

Show more characteristics
The maximum number of products that can be compared is 4. Remove already added products.

  • Main
    range of product
    Modicon Premium Automation platform
    product or component type
    Counter modules
    I/O modularity
    2 channels
    electrical circuit type
    Auxiliary output
    Complementary
    counting frequency
    40000 Hz
    power dissipation in W
    4.5…6 W
    cycle time
    5 ms
    discrete input logic
    Current sink for auxiliary input (preset, enable and read) conforming to IEC 1131 Type 2
    Resistive for 2/3-wire proximity sensors PNP/NPN conforming to IEC 1131 Type 2
    Resistive for encoder input
    input logic
    Positive
    input compatibility
    Incremental encoder 10...30 V totem pole
    Incremental encoder 5 V DC RS422
    input voltage
    24 V 18 mA 2/3-wire proximity sensors PNP/NPN
    24 V 7 mA auxiliary input (preset, enable and read)
    5 V 18 mA encoder input
    input voltage limits
    <= 5.5 V encoder input
    19...30 V 2/3-wire proximity sensors PNP/NPN
    19...30 V auxiliary input (preset, enable and read)
    voltage state 1 guaranteed
    >= 11 V for 2/3-wire proximity sensors PNP/NPN
    >= 11 V for auxiliary input (preset, enable and read)
    >= 2.4 V for encoder input
    current state 1 guaranteed
    >= 3.7 mA (encoder input)
    >= 6 mA (2/3-wire proximity sensors PNP/NPN)
    >= 6 mA (auxiliary input (preset, enable and read))
    voltage state 0 guaranteed
    <= 1.2 V for encoder input
    <= 5 V for 2/3-wire proximity sensors PNP/NPN
    <= 5 V for auxiliary input (preset, enable and read)
    current state 0 guaranteed
    <= 1 mA (encoder input)
    <= 2 mA (2/3-wire proximity sensors PNP/NPN)
    <= 2 mA (auxiliary input (preset, enable and read))
    response time
    < 2.5 ms sensor voltage at loss of 24 V auxiliary input (preset, enable and read)
    input impedance
    Encoder input: > 270 Ohm at U = 2.4 V
    2/3-wire proximity sensors PNP/NPN: 1400 Ohm at Un
    Auxiliary input (preset, enable and read): 3400 Ohm at Un
    Encoder input: 400 Ohm at Un
    output voltage
    24 V DC
    nominal output current
    0.5 A
    output voltage limits
    19...30 V
    maximum voltage drop
    <0.5 V at state 1
    output compatibility
    Positive logic DC inputs (resistance <= 15 kOhm) for auxiliary output
    maximum leakage current
    0.1 mA
    switching time
    < 0.25 ms
    switching frequency
    < 0.6/LI² Hz on inductive load load
    output overload protection
    Thermal tripping via program or automatically
    Current limiter
    output short-circuit protection
    Thermal tripping via program or automatically
    Current limiter
    output overvoltage protection
    Zener diode
    reverse polarity protection
    Reverse diode on supply
    checks
    Sensor power supply
    current consumption
    280 mA at 5 V DC
    30 mA at 24 V DC
    module format
    Standard
    local signalling
    1 LED (green)module operating (RUN):
    1 LED (red)external fault (I/O):
    1 LED (red)internal fault, module failure (ERR):
    2 LEDs (green)axis diagnostics available (CH.):
    electrical connection
    1 connector HE-10, 20 pins
    2 connectors SUB-D 15
    net weight
    0.32 kg
    Environment
    protective treatment
    TC
    Conformal coating Humiseal 1A33
    ambient air temperature for operation
    0…60 °C
    ambient air temperature for storage
    -25…70 °C
    relative humidity
    5…95 % without condensation
    operating altitude
    <= 2000 m
    Contractual warranty
    Warranty
    18 months
  • View more View less

    Documents

    Language
    • All Languages10
    • English10
    • French7
    User guide
    Format
    Size
    Date
    Add to My Documents
    Premium and Atrium using EcoStruxure™ Control Expert, Processors, Racks and Power Supply Modules (Version 10)
    Description
    This manual describes the hardware installation of the Premium and Atrium range of PLCs and their main accessories. It contains 6 parts: - General presentation of Premium and Atrium PLC stations, - TSX P57/TSX H57 Premium Processors, - TSX PCI 57 Atrium Processors, - TSX PSY Supply modules, - Process power supply modules, - Standard and extendable TSX RKY racks.
    prp.document.label.format pdf
    Size 3.6 MB
    Date 12/1/18
    Description
    This manual describes the hardware installation of the Premium and Atrium range of PLCs and their main accessories. It contains 6 parts: - General presentation of Premium and Atrium PLC stations, - TSX P57/TSX H57 Premium Processors, - TSX PCI 57 Atrium Processors, - TSX PSY Supply modules, - Process power supply modules, - Standard and extendable TSX RKY racks.
    Certificate
    Format
    Size
    Date
    Add to My Documents
    UL E486184 - NRAQ-NRAQ7 (Version 1.0)
    Files in document
    Description
    UL certificate for USA and Canada
    prp.document.label.format zip
    Size 343.5 KB
    Date 12/17/19
    Files in document
    Description
    UL certificate for USA and Canada
    CSA_225844_1041715_PREMIUM (Version 1.0)
    Description
    CSA for ordinary locations and hazardous locations
    prp.document.label.format pdf
    Size 159.3 KB
    Date 8/16/19
    Description
    CSA for ordinary locations and hazardous locations
    EAC_RUCFRME83B00163_PREMIUM_NOV2014 (Version 1.0)
    Description
    Eurasian Conformity
    prp.document.label.format pdf
    Size 1.8 MB
    Date 11/26/14
    Description
    Eurasian Conformity
    Declaration of conformity
    Format
    Size
    Date
    Add to My Documents
    DCC_PREMIUM_JUL2016 (Version 1.0)
    Description
    Manufacturer's Declaration of Conformity
    prp.document.label.format pdf
    Size 478.2 KB
    Date 7/20/16
    Description
    Manufacturer's Declaration of Conformity
    ACMA_RCM_PREMIUM_FEB2015 (Version 1.0)
    Description
    Australian Communications and Media Authority (ACMA)
    prp.document.label.format pdf
    Size 1.9 MB
    Date 2/10/15
    Description
    Australian Communications and Media Authority (ACMA)
    Marine certificate
    Format
    Size
    Date
    Add to My Documents
    MERCHANT_NAVY_PLC_INSTALLATION (Version 1.0)
    Description
    Merchant navies Installation Instructions
    prp.document.label.format pdf
    Size 181.4 KB
    Date 1/11/19
    Description
    Merchant navies Installation Instructions
    RMRS_16.00045.272_PREMIUM_DEC2016 (Version 1.0)
    Description
    Russian Maritime Register of Shipping
    prp.document.label.format pdf
    Size 1.6 MB
    Date 12/29/16
    Description
    Russian Maritime Register of Shipping
    DNV-GL Marine Certificate PREMIUM PLCs (Version 1.0)
    Description
    Det Norske Veritas
    prp.document.label.format pdf
    Size 164.4 KB
    Date 11/15/16
    Description
    Det Norske Veritas
    BV Marine Certificate PREMIUM PLCs (Version 1.0)
    Files in document
    Description
    Bureau Veritas
    prp.document.label.format zip
    Size 438.5 KB
    Date 8/17/16
    Files in document
    Description
    Bureau Veritas
  • Technical FAQs

    No results found
    Unfortunately, related FAQs are unavailable due to temporary technical issues. Please try again later.