Welcome to the Schneider Electric Website

Welcome to our website.

Select your location

View all   Preventa XPS
XPSAR311144 Product picture Schneider Electric

XPSAR311144

Green premium brand logo
XPSAR311144 Product picture Schneider Electric
XPSAR311144
Green premium brand logo

module XPSAR - Emergency stop - 24 V AC DC

Show more characteristics
Commercial status
To be discontinued on 30 June 2021
End-of-service soon on 31 December 2023
The maximum number of products that can be compared is 4

  • Main
    range of product
    Preventa Safety automation
    product or component type
    Preventa safety module
    safety module name
    XPSAR
    safety module application
    For emergency stop, switch and safety light curtain monitoring
    function of module
    Emergency stop monitoring 1-channel wiring
    Monitoring of electro-sensitive protection equipment (ESPE)
    Monitoring of a movable guard
    Multiple emergency stop monitoring 2-channel wiring
    Emergency stop with 2 NC contacts monitoring 2-channel wiring
    Monitoring of a movable guard associated with 2 switches and automatic start
    safety level
    Can reach PL e/category 4 conforming to EN/ISO 13849-1
    Can reach SILCL 3 conforming to EN/IEC 62061
    safety reliability data
    DC > 99 % conforming to EN/ISO 13849-1
    MTTFd = 277.8 years conforming to EN/ISO 13849-1
    PFHd = 2.22E-9 1/h conforming to EN/IEC 62061
    type of start
    Configurable
    connections - terminals
    Captive screw clamp terminals, 1 x 0.14...1 x 2.5 mm² flexible with cable end, with double bezel
    Captive screw clamp terminals, 1 x 0.14...1 x 2.5 mm² solid with cable end, with double bezel
    Captive screw clamp terminals, 1 x 0.25...1 x 1.5 mm² flexible with cable end, with double bezel
    Captive screw clamp terminals, 1 x 0.25...1 x 2.5 mm² flexible with cable end, with double bezel
    Captive screw clamp terminals, 2 x 0.14...2 x 0.75 mm² flexible with cable end, with double bezel
    Captive screw clamp terminals, 2 x 0.14...2 x 0.75 mm² solid with cable end, with double bezel
    Captive screw clamp terminals, 2 x 0.25...2 x 1 mm² flexible with cable end, with double bezel
    Captive screw clamp terminals, 2 x 0.5...2 x 1.5 mm² flexible with cable end, with double bezel
    output type
    Relay instantaneous opening, 7 NO circuit(s), volt-free
    number of additional circuits
    2 NC + 4 solid state outputs
    [Us] rated supply voltage
    24 V AC - 15...10 %
    24 V DC - 15...10 %
    Complementary
    synchronisation time between inputs
    100 ms
    supply frequency
    50/60 Hz
    maximum power consumption in W
    4 W DC
    maximum power consumption in VA
    7 VA AC
    input protection type
    Internal, electronic
    [Uc] control circuit voltage
    24 V DC
    maximum line resistance
    50 Ohm
    breaking capacity
    360 VA holding AC-15 C300 relay output
    3600 VA inrush AC-15 C300 relay output
    breaking capacity
    20 mA at 24 V
    2 A at 24 V (DC-13) time constant: 50 ms for relay output
    output thermal current
    10 A per relay for relay output
    [Ith] conventional free air thermal current
    40 A
    associated fuse rating
    10 A fast blow for relay output conforming to EN/IEC 60947-5-1, DIN VDE 0660 part 200
    6 A gG or gL for relay output conforming to EN/IEC 60947-5-1, DIN VDE 0660 part 200
    minimum output current
    170 mA for relay output
    minimum output voltage
    17 V for relay output
    maximum response time on input open
    20 ms
    [Ui] rated insulation voltage
    300 V (pollution degree 2) conforming to IEC 60947-5-1
    300 V (pollution degree 2) conforming to DIN VDE 0110 part 1
    [Uimp] rated impulse withstand voltage
    4 kV overvoltage category III conforming to IEC 60947-5-1
    4 kV overvoltage category III conforming to DIN VDE 0110 part 1
    local signalling
    4 LEDs
    current consumption
    20 mA at 24 V DC on power supply
    mounting support
    35 mm symmetrical DIN rail
    net weight
    0.3 kg
    Environment
    standards
    EN/ISO 13850
    EN/IEC 60947-5-1
    EN/IEC 60204-1
    EN 1088/ISO 14119
    product certifications
    CSA
    UL
    TÜV
    IP degree of protection
    IP20 (terminals) conforming to EN/IEC 60529
    IP40 (enclosure) conforming to EN/IEC 60529
    ambient air temperature for operation
    -10…55 °C
    ambient air temperature for storage
    -25…85 °C
    Offer Sustainability
    Sustainable offer status
    Green Premium product
    REACh Regulation
    EU RoHS Directive
    Pro-active compliance (Product out of EU RoHS legal scope)
    EU RoHS Declaration
    Mercury free
    Yes
    RoHS exemption information
    China RoHS Regulation
    Environmental Disclosure
    Circularity Profile
    WEEE
    The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins
    Contractual warranty
    Warranty
    18 months
  • View more View less

    Documents

    Language
    • All Languages14
    • English14
    • Chinese4
    • French4
    • German4
    CAD
    Format
    Size
    Date
    Add to My Documents
    CAD for XPSAR311144: module XPSAR - Emergency stop - 24 V AC DC (Version 1.0)
    Description
    You will be redirected to the ThomasNet website. Then you could download this CAD model in more than 15 different 2D or 3D CAD formats.
    CAD for XPSAR311144: module XPSAR - Emergency stop - 24 V AC DC (Version 1.0)
    Description
    You will be redirected to the ThomasNet website. Then you could download this CAD model in more than 15 different 2D or 3D CAD formats.
    Certificate
    Format
    Size
    Date
    Add to My Documents
    CCC_2007010303245539_Certificate_XPSAC_valid_20200227 (Version 1.2)
    Description
    CCC certificate of XPSAC, XPSAF, XPSAFL, XPSAK, XPSAR, XPSAV, XPSBF, XPSCM, XPSDMB, XPSDME, XPSMP, XPSTSA, XPSTSW, XPSVC, XPSATE, XPSVNE
    prp.document.label.format pdf
    Size 4.5 MB
    Date 12/11/19
    Description
    CCC certificate of XPSAC, XPSAF, XPSAFL, XPSAK, XPSAR, XPSAV, XPSBF, XPSCM, XPSDMB, XPSDME, XPSMP, XPSTSA, XPSTSW, XPSVC, XPSATE, XPSVNE
    prp.document.label.format htm
    Size 202 B
    Date 7/1/10
    prp.document.label.format pdf
    Size 1.2 MB
    Date 3/23/18
    Instruction sheet
    Format
    Size
    Date
    Add to My Documents
    prp.document.label.format pdf
    Size 344.3 KB
    Date 12/1/09
    China RoHS declaration
    Format
    Size
    Date
    Add to My Documents
    XPSAR311144 : XPSAR311144_ROHS_CHINA_DECLARATION
    Description
    XPSAR311144_ROHS_CHINA_DECLARATION
    prp.document.label.format pdf
    Size 195.3 KB
    Date 3/30/20
    Description
    XPSAR311144_ROHS_CHINA_DECLARATION
    Declaration of conformity
    Format
    Size
    Date
    Add to My Documents
    prp.document.label.format pdf
    Size 541.3 KB
    Date 6/12/18
    End of Life Information
    Format
    Size
    Date
    Add to My Documents
    prp.document.label.format pdf
    Size 2.2 MB
    Date 5/1/18
    prp.document.label.format pdf
    Size 784.4 KB
    Date 12/1/11
    EU RoHS Declaration
    Format
    Size
    Date
    Add to My Documents
    XPSAR311144 : XPSAR311144_ROHS_DECLARATION
    Description
    XPSAR311144_ROHS_DECLARATION
    prp.document.label.format pdf
    Size 195.3 KB
    Date 3/30/20
    Description
    XPSAR311144_ROHS_DECLARATION
    Product Environmental Profile
    Format
    Size
    Date
    Add to My Documents
    prp.document.label.format pdf
    Size 2.2 MB
    Date 5/1/18
    REACh Declaration
    Format
    Size
    Date
    Add to My Documents
    XPSAR311144 : XPSAR311144_REACH_DECLARATION
    Description
    XPSAR311144_REACH_DECLARATION
    prp.document.label.format pdf
    Size 195.3 KB
    Date 3/30/20
    Description
    XPSAR311144_REACH_DECLARATION
  • Technical FAQs

    No results found
    Unfortunately, related FAQs are unavailable due to temporary technical issues. Please try again later.
  • Dimensions Drawings

    Dimensions



Compare products: /