Aquaflair FC

Free cooling chillers with axial fans and integrated free-cooling system for continuous operation applications

The all-in-one integrated chilled water solution for data center cooling.

APC Brand Schneider Electric
Aquaflair FC schneider.label Free cooling chillers with axial fans and integrated free-cooling system for continuous operation applications
  • Ominaisuudet

    Free-cooling air cooled chillers leverages external air to remove the heat. These chillers not only reduce energy consumption compared to traditional systems, and therefore contribute to reduce global warming. Aquaflair FC unit are featured with embedded free-cooling, without increasing product footprint or clearances. All of Schneider Electric's Aquaflair Chillers offer low noise impact through the use of large air side heat exchangers, controlling fan rotation and insulated compressor section of the chiller. Our advanced controls system constantly monitors set points to guarantee the unit always operates within operating limits and will signal any faults before breakdown occurs. These chillers support a wide range of applications and maximize the availability of Row and Room cooling products to provide a complete heat removal solution

    Edut

    Availability

    • Active response control - Monitors and actively adjusts cooling capacity to ensure proper server inlet temperatures. Through the microprocessor controller, visibility into the operation and status of the unit is provided.
    • Quick restart - Full load operation in less than 3 minutes with specific arrangements permits undersizing of the storage tanks
    • Redundant Components - Single points of failure in the system have redundant compononents to maintain availability and reliability.
    • Separate power input - Draws power from the external UPS for mainboards and heaters to monitor and protect the unit even in complete power failure mode (optional)

    Manageability

    • Building management system integration - Send alarms and data points allowing you to manage critical building infrastructure from a single system.
    • Local area network - Creates a shared control between all the available resources for maximum energy efficiency and controlled management of the group during emergency situations
    • Microprocessor controller - Provides proactive control and real-time monitoring via a four line, eighty character, alphanumeric display.
    • Network interface - Provides management by connecting the device directly to the network with a dedicated IP address, avoiding the need for a proxy such as a server. Management is available via Web browser, Telnet or SSH. Notification features inform you of problems as they occur.

    Total Cost of Ownership

    • Integrated Hydronics Package - Includes all the necessary components to make one connection to the chilller without the need of external connections to auxiliary equipment such as pumps, increasing the speed of deployment.
    • Integrated pumps adjustment system - (Optional) VSD onboard pumps are available for continuous adjustment of the chilled water loop available pressure. This provides automatic adjustments in Chilled water flow due to changes in cooling demand which ensures efficiency of the chilled water system.
    • Modular strategy - Modular design of the mechanical and control systems allow for gradual build-up of the cooling infrastructure to match the cooling demand of the facility. This greatly reduces CAPEX expeditures and provides deferred investment throughout the life of the facility.
    • Optimized management - Connection between the Computer Room Air Conditioners and the chillers guarantees energy efficiency, based on real instantaneous load conditions (optional)
    • Quick restart - Full load operation in less than 3 minutes with specific arrangements permits undersizing of the storage tanks
    • Tandem compressors - Quiet and efficient operation of compressors, connected on a common refrigerant circuit for staged capacity control (not available for some models/configuration)

    Serviceability

    • Easy service access - Allows for all serviceable components to be replaced/maintained by easily accessible panels/doors.
    • Operational Service - Allows critical components to be maintained/replaced while the system is in operation.
    • Service monitoring - All the monitoring devices on board the unit allow for preventive maintenance and a check of the working condition of the system while its in operation.