Welcome to the Schneider Electric Website

Welcome to our website.

Select your location

View all   Phaseo ABL7, ABL8
ABL8RPM24200 Product picture Schneider Electric

ABL8RPM24200

Green premium brand logo
ABL8RPM24200 Product picture Schneider Electric
ABL8RPM24200
Green premium brand logo

regulated SMPS - 1 or 2-phase - 100..240 V - 24 V - 20 A

Show more characteristics
The maximum number of products that can be compared is 4

  • Main
    range of product
    Phaseo
    product or component type
    Power supply
    power supply type
    Regulated switch mode
    input voltage
    100...120 V AC single phase, terminal(s): N-L1
    200...240 V AC phase to phase, terminal(s): L1-L2
    output voltage
    24 V DC
    rated power in W
    480 W
    provided equipment
    Power factor correction filter conforming to IEC 61000-3-2
    power supply output current
    20 A
    output protection type
    Against overload, protection technology: manual or automatic reset
    Against overvoltage, protection technology: 30...32 V, manual reset
    Against short-circuits, protection technology: manual or automatic reset
    Against undervoltage, protection technology: tripping if U < 21.6 V
    Thermal, protection technology: automatic reset
    ambient air temperature for operation
    50…60 °C (with derating factor)
    -25…50 °C (without)
    Complementary
    input voltage limits
    85...132 V
    170...264 V
    network frequency
    47...63 Hz
    inrush current
    30 A 2 ms
    cos phi
    0.68 at 240 V
    0.69 at 120 V
    efficiency
    88 %
    output voltage limits
    24...28.8 V adjustable
    power dissipation in W
    57.6 W
    line and load regulation
    1...3 %
    holding time
    >= 120 ms at 400 V
    >= 20 ms at 100 V
    >= 40 ms at 240 V
    permissible temporary current boost
    1.5 x In (for 4 s)
    connections - terminals
    For diagnostic relay: removable screw terminal block, connection capacity: 2 x 2.5 mm²
    For input connection: screw type terminals, connection capacity: 3 x 0.5...3 x 4 mm² AWG 22...AWG 12
    For input ground connection: screw type terminals, connection capacity: 1 x 0.5...1 x 4 mm² AWG 22...AWG 12
    For output connection: screw type terminals, connection capacity: 4 x 0.5...4 x 4 mm² AWG 22...AWG 12
    marking
    CE
    mounting support
    35 x 7.5 mm symmetrical DIN rail
    35 x 15 mm symmetrical DIN rail
    operating position
    Vertical
    operating altitude
    2000 m
    output coupling
    Series
    Parallel
    name of test
    Electrostatic discharges conforming to EN/IEC 61000-4-2
    Induced electromagnetic field conforming to EN/IEC 61000-4-6
    Magnetic field conforming to EN 61000-4-8
    Primary outage conforming to IEC 61000-4-11
    Radiated electromagnetic field conforming to EN/IEC 61000-4-3
    Rapid transient conforming to IEC 61000-4-4
    Surge conforming to EN/IEC 61000-4-5
    Conducted emissions on the power line conforming to EN 55022 class B
    Radiated emissions conforming to EN 55022 class B
    Harmonic current emission conforming to EN/IEC 61000-3-2
    status LED
    1 LED (green and red)output voltage:
    1 LED (green, red and orange)output current:
    depth
    145 mm
    height
    125 mm
    width
    146 mm
    net weight
    1.6 kg
    Environment
    MTBF reliability
    717000 H at 100 V AC with UTE C80-810 calculation method
    695000 H at 240 V AC with UTE C80-810 calculation method
    product certifications
    CCSAus
    EAC
    KC
    RCM
    UL
    standards
    CSA C22.2 No 60950-1
    UL 508
    environmental characteristic
    EMC conforming to EN 61000-6-1
    EMC conforming to EN 61000-6-3
    EMC conforming to EN 55024
    EMC conforming to EN/IEC 61000-6-4
    EMC conforming to EN/IEC 61204-3
    Safety conforming to EN/IEC 60950-1
    Safety conforming to EN/IEC 61204-3
    Safety conforming to SELV
    IP degree of protection
    IP20 conforming to EN/IEC 60529
    IP10
    ambient air temperature for storage
    -40…70 °C
    relative humidity
    0…90 % during operation
    0…95 % in storage
    overvoltage category
    Class I conforming to VDE 0106-1
    dielectric strength
    2500 V between input and ground
    3000 V between input and output
    500 V between output and ground
    Offer Sustainability
    Sustainable offer status
    Green Premium product
    REACh Regulation
    EU RoHS Directive
    Pro-active compliance (Product out of EU RoHS legal scope)
    EU RoHS Declaration
    Mercury free
    Yes
    RoHS exemption information
    China RoHS Regulation
    Environmental Disclosure
    Circularity Profile
    Contractual warranty
    Warranty
    18 months
  • View more View less

    Documents

    Language
    • All Languages16
    • English16
    • French9
    • German9
    • Italian9
    • Portuguese9
    • Spanish9
    Catalogue
    Format
    Size
    Date
    Add to My Documents
    prp.document.label.format pdf
    Size 3.8 MB
    Date 2/12/19
    CAD
    Format
    Size
    Date
    Add to My Documents
    CAD for ABL8RPM24200: regulated SMPS - 1 or 2-phase - 100..240 V - 24 V - 20 A (Version 1.0)
    Description
    You will be redirected to the ThomasNet website. Then you could download this CAD model in more than 15 different 2D or 3D CAD formats.
    CAD for ABL8RPM24200: regulated SMPS - 1 or 2-phase - 100..240 V - 24 V - 20 A (Version 1.0)
    Description
    You will be redirected to the ThomasNet website. Then you could download this CAD model in more than 15 different 2D or 3D CAD formats.
    UNIV.POWER SUP.1P 24V 20A (Version 1.0)
    Files in document
    stp
    863.8 KB
    zip
    628.9 KB
    prp.document.label.format zip
    Size 1.5 MB
    Date 9/5/13
    Files in document
    stp
    863.8 KB
    zip
    628.9 KB
    prp.document.label.format zip
    Size 7.9 MB
    Date 4/30/08
    prp.document.label.format zip
    Size 7.7 MB
    Date 4/29/08
    Certificate
    Format
    Size
    Date
    Add to My Documents
    prp.document.label.format pdf
    Size 383.4 KB
    Date 1/15/16
    prp.document.label.format pdf
    Size 372.4 KB
    Date 12/8/14
    Instruction sheet
    Format
    Size
    Date
    Add to My Documents
    prp.document.label.format pdf
    Size 1.2 MB
    Date 10/1/14
    China RoHS declaration
    Format
    Size
    Date
    Add to My Documents
    ABL8RPM24200 : regulated SMPS - 1 or 2-phase - 100..240 V - 24 V - 20 A
    Description
    regulated SMPS - 1 or 2-phase - 100..240 V - 24 V - 20 A
    prp.document.label.format pdf
    Size 195.3 KB
    Date 2/23/20
    Description
    regulated SMPS - 1 or 2-phase - 100..240 V - 24 V - 20 A
    Declaration of conformity
    Format
    Size
    Date
    Add to My Documents
    prp.document.label.format pdf
    Size 593.7 KB
    Date 10/13/17
    End of Life Information
    Format
    Size
    Date
    Add to My Documents
    prp.document.label.format pdf
    Size 648.6 KB
    Date 1/1/15
    prp.document.label.format pdf
    Size 604.7 KB
    Date 1/1/15
    EU RoHS Declaration
    Format
    Size
    Date
    Add to My Documents
    ABL8RPM24200 : regulated SMPS - 1 or 2-phase - 100..240 V - 24 V - 20 A
    Description
    regulated SMPS - 1 or 2-phase - 100..240 V - 24 V - 20 A
    prp.document.label.format pdf
    Size 195.3 KB
    Date 2/23/20
    Description
    regulated SMPS - 1 or 2-phase - 100..240 V - 24 V - 20 A
    Product Environmental Profile
    Format
    Size
    Date
    Add to My Documents
    prp.document.label.format pdf
    Size 4.1 MB
    Date 11/1/14
    REACh Declaration
    Format
    Size
    Date
    Add to My Documents
    ABL8RPM24200 : regulated SMPS - 1 or 2-phase - 100..240 V - 24 V - 20 A
    Description
    regulated SMPS - 1 or 2-phase - 100..240 V - 24 V - 20 A
    prp.document.label.format pdf
    Size 195.3 KB
    Date 2/23/20
    Description
    regulated SMPS - 1 or 2-phase - 100..240 V - 24 V - 20 A
  • Technical FAQs

    No results found.
    Unfortunately, related FAQs are unavailable due to temporary technical issues. Please try again later.
  • Dimensions Drawings

    Regulated Switch Mode Power Supplies
    Dimensions


    ABL 8

    a in mm

    a in in.

    b in mm

    b in in.

    RPS24030

    125

    4.92

    45

    1.77

    RPS24050

    125

    4.92

    56

    2.20

    RPS24100

    145

    5.71

    86

    3.39

    RPM24200

    145

    5.71

    146

    5.75

    WPS24200

    160

    6.30

    96

    3.78

    WPS24400

    160

    6.30

    166

    6.54


  • Connections and Schema

    Regulated Switch Mode Power Supply
    Internal Wiring Diagram



    Regulated Switch Mode Power Supply
    Line Supply Wiring Diagram

    Single-phase (L-N) 100 to 120 V


    Phase-to-phase (L1-L2) 200 to 500 V


    Single-phase (L-N) 200 to 500 V



    Regulated Switch Mode Power Supplies
    Series or Parallel Connection

    Series Connection


    (1)
    Two Shottky diodes Imin = power supply In and Vmin = 50 V

    Parallel Connection


    Family

    Series

    Parallel

    ABL 8RPS/8RPM/8WPS

    2 products max. (1)

    2 products max.

    NOTE: Series or parallel connection is only recommended for products with identical references.

    For better availability, the power supplies can also be connected in parallel using the ABL8RED24400 Redundancy module.


  • Performance Curves

    Regulated Switch Mode Power Supplies
    Derating

    The ambient temperature is a determining factor that limits the power an electronic power supply can deliver continuously. If the temperature around the electronic components is too high, their life will be significantly reduced.

    The nominal ambient temperature for the Universal range of Phaseo power supplies is 50°C. Above this temperature, derating is necessary up to a maximum temperature of 60°C.

    The graph below shows the power (in relation to the nominal power) that the power supply can deliver continuously, depending on the ambient temperature.


    X
    Maximum operating temperature (°C)

    ABL 8RPM, ABL 8RPS, ABL 8WPS mounted vertically

    Derating should be considered in extreme operating conditions:

    • Intensive operation (output current permanently close to the nominal current, combined with a high ambient temperature)

    • Output voltage set above 24 Vdc (to compensate for line voltage drops, for example)

    • Parallel connection to increase the total power


    Regulated Switch Mode Power Supply
    Load Limit

    Manual Reset Protection Mode


    (1)
    Boost 4s

    Automatic Reset Protection Mode


    (1)
    Boost 4s

    “Boost” Repeat Accuracy


    This type of operation is described in detail in the user manual, which can be downloaded from the website.