Welcome to the Schneider Electric Website

Welcome to our website.

Select your location

Welcome the the Schneider Electric French website. It looks like you are located in the United States, would you like to change your location?

Traduisez en francais
View all   TeSys F
LC1F1154E7 Product picture Schneider Electric
Discontinued

LC1F1154E7

Green premium brand logo
LC1F1154E7 Product picture Schneider Electric
Discontinued
LC1F1154E7
Green premium brand logo

TeSys F contactor - 4P (4 NO) - AC-1 - <= 440 V 200 A - coil 48 V AC

Show more characteristics
Commercial status
Discontinued on 10 October 2020
End-of-service on 10 October 2020
LC1F1154E7  has not been replaced. Please contact your customer care centrefor more information.
The maximum number of products that can be compared is 4. Remove already added products.

  • Main
    range
    TeSys
    product name
    TeSys F
    product or component type
    Contactor
    device short name
    LC1F
    contactor application
    Resistive load
    utilisation category
    AC-1
    poles description
    4P
    power pole contact composition
    4 NO
    [Ue] rated operational voltage
    <= 690 V AC 50/60 Hz
    [Ie] rated operational current
    200 A (at <40 °C) at <= 440 V AC-1
    [Uc] control circuit voltage
    48 V AC 40...400 Hz
    Complementary
    [Uimp] rated impulse withstand voltage
    8 kV
    overvoltage category
    III
    [Ith] conventional free air thermal current
    200 A (at 40 °C)
    rated breaking capacity
    920 A conforming to IEC 60947-4-1
    [Icw] rated short-time withstand current
    1100 A 40 °C - 10 s
    640 A 40 °C - 30 s
    520 A 40 °C - 1 min
    400 A 40 °C - 3 min
    320 A 40 °C - 10 min
    associated fuse rating
    125 A aM at <= 440 V
    200 A gG at <= 440 V
    average impedance
    0.37 mOhm - Ith 200 A 50 Hz
    [Ui] rated insulation voltage
    1000 V conforming to IEC 60947-4-1
    1500 V conforming to VDE 0110 group C
    power dissipation per pole
    15 W AC-1
    mounting support
    Plate
    standards
    IEC 60947-4-1
    EN 60947-1
    JIS C8201-4-1
    EN 60947-4-1
    IEC 60947-1
    product certifications
    CB
    CCC
    UL
    ABS
    BV
    RMRoS
    RINA
    DNV
    LROS (Lloyds register of shipping)
    connections - terminals
    Power circuit: bar 2 cable(s) - busbar cross section: 20 x 3 mm
    Power circuit: lugs-ring terminals 1 cable(s) 95 mm²
    Power circuit: connector 1 cable(s) 95 mm²
    Control circuit: screw clamp terminals 1 cable(s) 1…4 mm²flexible without cable end
    Control circuit: screw clamp terminals 2 cable(s) 1…4 mm²flexible without cable end
    Control circuit: screw clamp terminals 1 cable(s) 1…4 mm²flexible with cable end
    Control circuit: screw clamp terminals 2 cable(s) 1…2.5 mm²flexible with cable end
    Control circuit: screw clamp terminals 1 cable(s) 1…4 mm²solid without cable end
    Control circuit: screw clamp terminals 2 cable(s) 1…4 mm²solid without cable end
    Power circuit: bolted connection
    tightening torque
    Power circuit: 10 N.m
    Control circuit: 1.2 N.m
    control circuit voltage limits
    Operational: 0.85...1.1 Uc 40...400 Hz (at 55 °C)
    Drop-out: 0.35...0.55 Uc 40...400 Hz (at 55 °C)
    inrush power in VA
    770 VA 40...400 Hz cos phi 0.9 (at 20 °C)
    hold-in power consumption in VA
    8.1 VA 40...400 Hz cos phi 0.9 (at 20 °C)
    heat dissipation
    5.9…7.2 W
    operating time
    35 ms closing (at Uc)
    130 ms opening (at Uc)
    mechanical durability
    10 Mcycles
    maximum operating rate
    2400 cyc/h 55 °C
    compatibility code
    LC1F
    Environment
    IP degree of protection
    IP2x front face with shrouds conforming to IEC 60529
    IP2x front face with shrouds conforming to VDE 0106
    protective treatment
    TH
    ambient air temperature for operation
    -40…60 °C
    ambient air temperature for storage
    -60…80 °C
    permissible ambient air temperature around the device
    60…70 °C at Uc
    operating altitude
    3000 m without derating
    height
    162 mm
    width
    200.5 mm
    depth
    171 mm
    net weight
    3.83 kg
    Packing Units
    Unit Type of Package 1
    PCE
    Number of Units in Package 1
    1
    Package 1 Weight
    4.82 kg
    Package 1 Height
    22 cm
    Package 1 width
    21.5 cm
    Package 1 Length
    26.5 cm
    Offer Sustainability
    Sustainable offer status
    Green Premium product
    REACh Regulation
    EU RoHS Directive
    Mercury free
    Yes
    RoHS exemption information
    China RoHS Regulation
    China RoHS declaration
    Product out of China RoHS scope. Substance declaration for your information
    Environmental Disclosure
    Circularity Profile
    WEEE
    The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins
    Contractual warranty
    Warranty
    18 months
  • View more
    View less

    Documents

    Language
    • All Languages14
    • English14
    • Chinese6
    • French7
    • German6
    • Italian6
    • Portuguese6
    • Russian6
    • Spanish6
    Catalogue
    Format
    Size
    Date
    Add to My Documents
    TeSys - Catalogue 2020 - Innovative and connected solutions for motor starters (Version 10.0)
    Description
    Ready-to-use motor starters and all components for building specific motor starters ( circuit breakers, contactors, overload relays , accessories ...). This edition includes a presentation of the new TeSys island system. The catalogue can also be downloaded chapter per chapter.
    prp.document.label.format pdf
    Size 118.2 MB
    Date 7/22/20
    Description
    Ready-to-use motor starters and all components for building specific motor starters ( circuit breakers, contactors, overload relays , accessories ...). This edition includes a presentation of the new TeSys island system. The catalogue can also be downloaded chapter per chapter.
    TeSys catalogue - 2020 - chapter B9 high power contactors TeSys F,V, FG, CR1F (Version 8.0)
    Description
    Contactors for AC-3, AC-1 application, reversing AC-3 pre-cabled, changeover AC-1 precabled : TeSys FVacuum contactors : TeSys VShockproof contactors : TeSys FGMagnetic latching contactors : TeSys CR1FCoils, accessories
    prp.document.label.format pdf
    Size 11.2 MB
    Date 7/22/20
    Description
    Contactors for AC-3, AC-1 application, reversing AC-3 pre-cabled, changeover AC-1 precabled : TeSys FVacuum contactors : TeSys VShockproof contactors : TeSys FGMagnetic latching contactors : TeSys CR1FCoils, accessories
    CAD
    Format
    Size
    Date
    Add to My Documents
    TeSys F 1154 contactor (Version 1.0)
    Files in document
    pdf
    344.5 KB
    stp
    852.5 KB
    Description
    CAD file
    prp.document.label.format zip
    Size 1.2 MB
    Date 2/9/17
    Files in document
    pdf
    344.5 KB
    stp
    852.5 KB
    Description
    CAD file
    Certificate
    Format
    Size
    Date
    Add to My Documents
    prp.document.label.format pdf
    Size 2.1 MB
    Date 4/17/17
    Instruction sheet
    Format
    Size
    Date
    Add to My Documents
    prp.document.label.format pdf
    Size 4.5 MB
    Date 4/1/19
    prp.document.label.format pdf
    Size 6 MB
    Date 1/2/19
    China RoHS declaration
    Format
    Size
    Date
    Add to My Documents
    LC1F1154E7 : TeSys F contactor - 4P (4 NO) - AC-1 - <= 440 V 200 A - coil 48 V AC
    Description
    TeSys F contactor - 4P (4 NO) - AC-1 - <= 440 V 200 A - coil 48 V AC
    prp.document.label.format pdf
    Size 195.3 KB
    Date 11/26/20
    Description
    TeSys F contactor - 4P (4 NO) - AC-1 - <= 440 V 200 A - coil 48 V AC
    Declaration of conformity
    Format
    Size
    Date
    Add to My Documents
    prp.document.label.format pdf
    Size 301.8 KB
    Date 7/4/19
    End of Life Information
    Format
    Size
    Date
    Add to My Documents
    prp.document.label.format pdf
    Size 302.6 KB
    Date 6/15/10
    EU RoHS Declaration
    Format
    Size
    Date
    Add to My Documents
    LC1F1154E7 : TeSys F contactor - 4P (4 NO) - AC-1 - <= 440 V 200 A - coil 48 V AC
    Description
    TeSys F contactor - 4P (4 NO) - AC-1 - <= 440 V 200 A - coil 48 V AC
    prp.document.label.format pdf
    Size 195.3 KB
    Date 11/26/20
    Description
    TeSys F contactor - 4P (4 NO) - AC-1 - <= 440 V 200 A - coil 48 V AC
    Marine certificate
    Format
    Size
    Date
    Add to My Documents
    prp.document.label.format pdf
    Size 20.1 MB
    Date 10/16/18
    prp.document.label.format pdf
    Size 272.4 KB
    Date 5/29/17
    REACh Declaration
    Format
    Size
    Date
    Add to My Documents
    LC1F1154E7 : TeSys F contactor - 4P (4 NO) - AC-1 - <= 440 V 200 A - coil 48 V AC
    Description
    TeSys F contactor - 4P (4 NO) - AC-1 - <= 440 V 200 A - coil 48 V AC
    prp.document.label.format pdf
    Size 195.3 KB
    Date 11/26/20
    Description
    TeSys F contactor - 4P (4 NO) - AC-1 - <= 440 V 200 A - coil 48 V AC
  • Technical FAQs

    No results found.
    Unfortunately, related FAQs are unavailable due to temporary technical issues. Please try again later.