Dobro došli na Schneider Electric web

Posjeti naš web u drugoj državi ili regiji ili otvori naše globalni web.

Odaberi svoju lokaciju

Welcome the the Schneider Electric French website. It looks like you are located in the United States, would you like to change your location?

Traduisez en francais

Data Center Operation: Cooling Optimize

Dynamically eliminates hot spots and saves energy through intelligent cooling control.

Active cooling control for optimized resource usage and energy savings.

Slika proizvoda APC Brand Schneider Electric
Data Center Operation: Cooling Optimize
  • Prednosti

    Cost Savings
    • Extend equipment life - Efficient use of cooling equipment reduces the need for maintenance and extends equipment life.
    • Energy savings - Delivers up to 40% cooling energy savings through optimized use of existing cooling equipment.
    Dostupnost
    • Uptime protection - Immediate identification and elimination of hot spots protects uptime and ensures business can continue as planned.
    • Benchmark report - Verifies energy and cost savings, as well as greenhouse gas reductions, achieved through the use of active cooling control.
    • Existing cooling infrastructure - Works with your existing infrastructure; direct expansion (DX), chilled water, economizers and evaporative cooling methods, and under floor, overhead, ducted and unducted airflow environments.
    • Manual override - Provides operators with the ability to manually exert control over their cooling resources and override the system.
    • Risk mitigation - In the event of an emergency, cooling units will automatically run at maximum capacity and ensure a cool facility, even if Cooling Optimize is unable to connect to and control the cooling units.
    • Temperature compliance report - Identifies if rack temperatures have complied with required set points, and the time period that racks have been in violation of the set point limits, enabling easy detection of potential physical infrastructure irregularities.
    Upravljivost
    • Intelligent control - Temperature data is wirelessly transmitted to network gateways, aggregated, and analyzed by control software, which determines appropriate control demands delivered directly to the cooling equipment.
    • Dynamic optimization - Thermal airflow is constantly adapted to match real-time needs created by the dynamic environment in a data center.
    • Reclaim cooling capacity - Continuously optimized cooling capacity allows for additional IT load and increased IT capacity in the data center.
    • Influence mapping - Provides great insights into the influence of individual cooling units on the temperature in every part of the data center.
    Zaštita
    • Pristup više korisnika - Omogućuje nekoliko korisnika istodobno obavljanje radova na aplikaciji i jednostavno povezivanje izmjena raznih korisnika.
    • Uloge korisnika - Zahvaljujući mogućnosti prijave više korisnika i određivanju više pojedinačnih razina uloga korisnika omogućeno je jednostavno lociranje i pristup utemeljen na značajkama.
    • Wireless temperature sensors - Utilizes a range of wireless temperature sensors to determine the exact position of the heat load within the data center
    • Pristup samo za čitanje - Podijelite pristup bez rizika neovlaštenih promjena konfiguracija.
    • Zaštićeno lozinkom - Zaštita lozinkom koju određuje sam korisnik sprječava neovlašten pristup, s posebnom zaštitom za LDAP i Active Directory poslužitelje.

Kontaktiraj nas

Pronađi dodatne informacije o proizvodima ili zatraži tehničku podršku.

FAQ

Pronađi odgovore ili ih podijeli s drugima u našoj bazi često postavljanih pitanja - FAQ.

Gdje kupiti?

Pronađi kontakte naših partnera