ProDiag Breaker Preventive maintenance diagnosis with shut down for MV & LV Circuit Breakers
ProDiag Breaker mitigates the risks of Circuit Breaker full operating chain kinematic drift, versus original equipment technical specifications, to estimate how close the equipment is to failure. Download
-
ProDiag Corona Preventive maintenance diagnosis without shut down for MV switchgears
ProDiag Corona mitigates the risks of MV equipment insulating parts accelerated wearing or ageing.
These effects cause surface or internal partial discharges origin of arc risk and unwanted tripping. Discover now -
ProDiag LV Trip Unit Preventive maintenance diagnosis with shutdown for LV circuit Breakers
ProDiag Trip Unit mitigates the risks of non accurate tripping time operation in accordance with original settings. It verifies LV Breaker consistency with electrical network parameters (discrimination, breaking capacity). We analyse all alarms and events occurred since the last intervention. Learn more
-
ProDiag MV Relay Preventive maintenance diagnosis with shutdown for MV Protection Relays
ProDiag MV Relay assesses protection relays conformity according to original product specifications as per tripping curves.It diagnoses the protection relay performance on the operating time between the tripping order and the opening of the main contact of the breaker. Know more
-
MCset Medium Voltage distribution switchgear recommended maintenance service
Preventive maintenance activities conducted by Schneider Electric skilled professionals. Combinations of activities consisting of regular inspections, work on mechanisms, and spare parts replacement on your MCset Switchgear. Its avoids any possible failure. Find out more
-
SM6 Medium Voltage distribution switchgear recommended maintenance service
Preventive maintenance activities conducted by Schneider Electric skilled professionals. Combinations of activities consisting of regular inspections, work on mechanisms, and spare parts replacement on your SM6 Switchgear. Its avoids any possible failure. Read now
-
Masterpact M Low Voltage distribution circuit breaker recommended maintenance service
Preventive maintenance activities conducted by Schneider Electric skilled professionals. Combinations of activities consisting of regular inspections, work on mechanisms, and spare parts replacement on your Masterpact M. Its avoids any possible failure. Download the brochure now
-
Masterpact NT / NW Low Voltage distribution circuit breaker recommended maintenance service
Preventive maintenance activities conducted by Schneider Electric skilled professionals. Combinations of activities consisting of regular inspections, work on mechanisms, and spare parts replacement on your Masterpact NT/NW. Its avoids any possible failure. Explore now
-
Electrical Distribution Maintenance Fundamentals
This paper discusses basic electrical distribution maintenance concepts, including the purpose and characteristics of different types of maintenance, frequency of maintenance intervention, and spare parts policies. Read more
-
Electrical Distribution Maintenance digital leaflet
As a global energy management specialist, Schneider Electric has extensive knowledge and experience in electrical distribution maintenance. This leaflet presents Schneider Electric Maintenance & Diagnostics offer categories. Read more
-
-
Virtual visit
ProDiag Oil Preventive maintenance diagnosis with shutdown for oil distribution transformer
ProDiag Oil mitigates the risks of oil degradation as origin of oil transformer malfunctions such as overheating risks, electrical arcing, fire etc. It characterizes the dielectric oil quality, solid insulation performances and furan derivatives. Discover the animation -
Watch
-
ProDiag Preventive maintenance diagnostics
ProDiag reduces the possibility of unexpected downtime and helps you anticipate equipment failure. -
ProDiag Breaker Preventive maintenance diagnosis with shut down for MV & LV Circuit Breakers
ProDiag Breaker mitigates the risks of Circuit Breaker full operating chain kinematic drift, versus original equipment technical specifications, to estimate how close the equipment is to failure. -
ProDiag Corona Preventive maintenance diagnosis without shut down for MV switchgears
ProDiag Corona mitigates the risks of MV equipment insulating parts accelerated wearing or ageing.
These effects cause surface or internal partial discharges origin of arc risk and unwanted tripping. -
ProDiag LV Trip Unit Preventive maintenance diagnosis with shutdown for LV circuit Breakers
ProDiag Trip Unit mitigates the risks of non accurate tripping time operation in accordance with original settings. It verifies LV Breaker consistency with electrical network parameters (discrimination, breaking capacity). We analyze all alarms and events occurred since the last intervention. -
ProDiag MV Relay Preventive maintenance diagnosis with shutdown for MV Protection Relays
ProDiag MV Relay assesses protection relays conformity according to original product specifications as per tripping curves.It diagnoses the protection relay performance on the operating time between the tripping order and the opening of the main contact of the breaker. -
ProDiag Fuse Preventive maintenance diagnosis with shutdown on MV fuses.
ProDiag Fuse mitigates the risks on MV fuses of faults/drifts by premature ageing (thermal or electrical over-stressing). This is the destruction of filaments that can lead to thermal runaway, partial damage etc. It checks fuse electrical parameters according to original technical specifications.
-