How to reset the password of the FlexNet Publisher back to default
Issue
The FlexNet Publisher (FNP) is a web interface hosted on the PME server for configuring licensing components.
The default user name and password for FlexNet Publisher (FNP) is admin/admin.
If the password is changed to something else, the default admin/admin combination will not work.
Product Line
Power Monitoring Expert 7.2.x
Power Monitoring Expert 8.x
NOTE: Does NOT apply to PME 9.0 and greater
FlexNet Publisher
Cause
The default password has been changed (admin is the default password).
Resolution
*Warning: Take backups of any files prior to modifying them. Ensure the backups are in a location
that will not be overwritten (i.e. the Desktop).
*Warning: Take backups of any files prior to modifying them. Ensure the backups are in a location that will not be overwritten (i.e. the Desktop).
Following the procedure below, the password of the FlexNet Publisher can be reset to its default: "admin" (without the quotation mark).
- Navigate to:
On Power Monitoring Expert 7.2.x:
C:\Program Files (x86)\Schneider Electric\Power Monitoring Expert\Floating License Manager\FLEXnet Publisher License Server Manager\conf
On Power Monitoring Expert 8.x
C:\ProgramData\Schneider Electric\Floating License Manager\FLEXnet Publisher License Server Manager\conf
- Open the 'server.xml' in Notepad or any suitable XML editor.
- Search for: lastName="Administrator"
- Replace the contents of the password field as shown below:
id="admin" lastName="Administrator" password="(ENC-01)AxlKxBaCLbp4iPFsjJ6eOFtE+qoJWH8ThHIKN9DgdEgILS9j" passwordExpired="false"
For example if you want to change the password back to admin, here is what the line would look like:
id="admin" lastName="Administrator" password="admin" passwordExpired="false"
- Restart the "lmadminSchneider" service from 'Services'.
- Login to the Flexnet Publisher by navigating to http://localhost:8090 and clicking on 'Administration'. Use the following credentials to sign in if the password was changed to "admin" on step 4:
Username: admin
password: admin
Note: The user name is always "admin"