GPFat BC500RTL.DLL after using the adcanced Button in a DFB

Goals and Symptoms

When you click on a DFB and push the advanced button, you will get an error: "CONCEPT causes a fault in BC500RTL.DLL..address 0001:1468".

Facts and Changes

All Concept Versions until V2.6 SR2 patch a.

Causes and Fixes

GPF occurs on PCs where the Environment-Variable "PATH" contains a path with around 600 Bytes. To reduce the path length, you can deinstal programs, which have inserted directory names in the path string. You can also edit the path variable and delete not needed directories:
Control Panel \ System \ Advanced \ Environment variables


Legacy KB System (APS) Data: RESL167969 V1.0, Originally authored by on , Last Edited by on
Related ranges: Concept