Welcome to the Schneider Electric Website

Welcome to our website.

Select your location

Welcome the the Schneider Electric French website. It looks like you are located in the United States, would you like to change your location?

Traduisez en francais
View all   Zelio interfaces ABR/ABS
ABR2S102B Product picture Schneider Electric

ABR2S102B

ABR2S102B Product picture Schneider Electric
ABR2S102B

output interface module - 9.5 mm - electromechanical - 24 V DC - 1 NC

Show more characteristics
The maximum number of products that can be compared is 4. Remove already added products.

  • Main
    range of product
    Interface for discrete signals
    product or component type
    Slim electromechanical output interface module
    contacts type and composition
    1 NO
    [Uc] control circuit voltage
    24 V
    control circuit type
    DC
    width pitch dimension
    12 mm
    maximum [In] rated current
    18 mA
    reverse polarity protection
    With
    short-circuit protection
    6.3 A external fuse fast blow (Ik <= 1 kA AC and Ik <= 100 A DC)
    [Ith] conventional free air thermal current
    5 A conforming to IEC 60947-1
    sale per indivisible quantity
    5
    Complementary
    control circuit voltage limits
    28.8 V energization threshold: 14.5 V
    connections - terminals
    Screw clamp terminal
    drop-out voltage
    2 V
    holding current
    1.3 mA
    power dissipation in W
    0.43 W
    maximum switching voltage
    150 V DC
    250 V AC
    [Ue] rated operational voltage
    <= 120 V DC conforming to IEC 60947-5-1
    <= 230 V AC conforming to IEC 60947-5-1
    network frequency
    50/60 Hz
    [Ie] rated operational current
    1 A AC-14 Ue: 230 V per 1000000 cycles conforming to IEC 60947-5-1
    1 A AC-15 Ue: 230 V per 1000000 cycles conforming to IEC 60947-5-1
    3 A AC-12 Ue: 230 V per 1000000 cycles conforming to IEC 60947-5-1
    1.5 A DC-13 Ue: 24 V per 1000000 cycles conforming to IEC 60947-5-1
    1.7 A DC-12 Ue: 24 V per 1000000 cycles conforming to IEC 60947-5-1
    minimum switching current
    5 mA
    minimum switching voltage
    5 V
    electrical reliability
    <= 0.00000001
    operating time
    <= 10 ms between energisation of coil and closing of NO contact DC
    <= 5 ms between de-energisation of coil and closing of NO contact DC
    contact bounce time
    <= 5 ms
    operating rate in Hz
    10 Hz at no-load
    0.5 Hz at Ie
    mechanical durability
    10000000 cycles
    [Ui] rated insulation voltage
    250 V conforming to VDE 0110 group C
    300 V conforming to IEC 60947-1
    flame retardance
    V0 conforming to UL 94
    cable cross section
    0.34…2.5 mm², 1 or 2 wires flexible with cable end
    0.6…2.5 mm², 1 or 2 wires flexible without cable end
    0.27…4 mm², 1 wire rigid
    operating position
    Any position
    installation category
    II conforming to IEC 60947-1
    mounting support
    Symmetrical DIN rail
    Asymmetrical DIN rail
    Combination rail
    net weight
    0.04 kg
    Environment
    immunity to microbreaks
    5 ms
    dielectric strength
    1000 V for 1 minute between open contacts
    2500 V for 1 minute between wired interface and earth
    4000 V for 1 minute between coil circuit and contact circuits
    standards
    IEC 60947-5-1
    product certifications
    BV
    CSA
    DNV
    LROS (Lloyds register of shipping)
    UL
    IP degree of protection
    IP20 conforming to IEC 60529
    protective treatment
    TC
    fire resistance
    960 °C conforming to IEC 60695-2-1
    shock resistance
    30 gn for 11 ms conforming to IEC 60068-2-27
    vibration resistance
    3 gn conforming to IEC 60068-2-6 (f = 10…150 Hz)
    electromagnetic compatibility
    Electromagnetic field immunity test: level 3 10 V/m between 27...1000 MHz conforming to IEC 61000-4-3
    Electrostatic discharge immunity test: level 3 8 kV conforming to IEC 61000-4-2
    Fast transients immunity test: level 3 on input/output 1 kV conforming to IEC 61000-4-4
    Fast transients immunity test: level 3 on power supply 2 kV conforming to IEC 61000-4-4
    1.2/50 µs shock waves immunity test conforming to IEC 60947-1
    1.2/50 µs shock waves immunity test conforming to IEC 60947-1
    1.2/50 µs shock waves immunity test conforming to IEC 60947-1
    ambient air temperature for operation
    -25…55 °C at Us
    -25…70 °C at Us with 8 mm space between ABR2S1...
    -5…40 °C unrestricted operation
    -5…55 °C from 0.85...1.1 Us
    ambient air temperature for storage
    -40…80 °C
    operating altitude
    <= 3000 m
    pollution degree
    2 conforming to IEC 60947-1
    Packing Units
    Unit Type of Package 1
    PCE
    Number of Units in Package 1
    1
    Package 1 Weight
    47 g
    Package 1 Height
    7 cm
    Package 1 width
    9 cm
    Package 1 Length
    11.7 cm
    Unit Type of Package 2
    BB1
    Number of Units in Package 2
    5
    Package 2 Weight
    237 g
    Package 2 Height
    7 cm
    Package 2 width
    9 cm
    Package 2 Length
    11.7 cm
    Unit Type of Package 3
    S02
    Number of Units in Package 3
    75
    Package 3 Weight
    3.946 kg
    Package 3 Height
    15 cm
    Package 3 width
    30 cm
    Package 3 Length
    40 cm
    Offer Sustainability
    EU RoHS Directive
    Pro-active compliance (Product out of EU RoHS legal scope)
    EU RoHS Declaration
    Mercury free
    Yes
    RoHS exemption information
    China RoHS Regulation
    Environmental Disclosure
    WEEE
    The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins
    Contractual warranty
    Warranty
    18 months
  • View more View less

    Documents

    Language
    • All Languages7
    • English7
    • French1
    • German1
    • Italian1
    • Portuguese1
    • Spanish1
    Certificate
    Format
    Size
    Date
    Add to My Documents
    prp.document.label.format htm
    Size 213 B
    Date 09/03/09
    Instruction sheet
    Format
    Size
    Date
    Add to My Documents
    prp.document.label.format pdf
    Size 37.9 KB
    Date 08/01/99
    Description
    None
    China RoHS declaration
    Format
    Size
    Date
    Add to My Documents
    ABR2S102B : output interface module - 9.5 mm - electromechanical - 24 V DC - 1 NC
    Description
    output interface module - 9.5 mm - electromechanical - 24 V DC - 1 NC
    prp.document.label.format pdf
    Size 195.3 KB
    Date 08/07/20
    Description
    output interface module - 9.5 mm - electromechanical - 24 V DC - 1 NC
    Declaration of conformity
    Format
    Size
    Date
    Add to My Documents
    EU DOC - Zelio Interfaces ABR-1 ABR-2 ABS-2 (Version Add ROHS Directive)
    Description
    Zelio Interfaces ABR-1 ABR-2 ABS-2
    prp.document.label.format pdf
    Size 393.1 KB
    Date 22/07/19
    Description
    Zelio Interfaces ABR-1 ABR-2 ABS-2
    EU RoHS Declaration
    Format
    Size
    Date
    Add to My Documents
    ABR2S102B : output interface module - 9.5 mm - electromechanical - 24 V DC - 1 NC
    Description
    output interface module - 9.5 mm - electromechanical - 24 V DC - 1 NC
    prp.document.label.format pdf
    Size 195.3 KB
    Date 08/07/20
    Description
    output interface module - 9.5 mm - electromechanical - 24 V DC - 1 NC
    Product Environmental Profile
    Format
    Size
    Date
    Add to My Documents
    prp.document.label.format pdf
    Size 3.4 MB
    Date 01/04/17
    REACh Declaration
    Format
    Size
    Date
    Add to My Documents
    ABR2S102B : output interface module - 9.5 mm - electromechanical - 24 V DC - 1 NC
    Description
    output interface module - 9.5 mm - electromechanical - 24 V DC - 1 NC
    prp.document.label.format pdf
    Size 195.3 KB
    Date 08/07/20
    Description
    output interface module - 9.5 mm - electromechanical - 24 V DC - 1 NC
  • Technical FAQs

    No results found
    Unfortunately, related FAQs are unavailable due to temporary technical issues. Please try again later.
  • Dimensions Drawings

    Slim Electromechanical Interface Module
    Dimensions



  • Connections and Schema

    Slim Electromechanical Interface Module
    Example of Application with PLC

    Interfacing PLC discrete outputs


    (1)
    Essential on inductive loads (can be replaced with peak limiter)
    (2)
    PLC positive logic transistor (or relay) outputs
    (3)
    PLC analog inputs
    (4)
    Channel X
    (5)
    Analog sensors


    Slim Electromechanical Interface Module
    Circuit Diagram

    1 N/O



  • Performance Curves

    Electrical Durability of Contacts
    AC Loads

    Test conditions: in accordance with standard IEC 947-5-1 set up for rated control voltage.

    AC-12 operating cycles in millions


    AC-12
    Control of resistive loads and isolated solid state loads via optocoupler (cos ϕ ≥ 0.9)
    (1)
    24 V
    (2)
    48 V
    (3)
    115 V
    (4)
    230 V

    AC-14 and AC-15 operating cycles in millions


    AC-14
    Control of weak electro-magnetic loads of electro-magnets ≤ 72 VA (make: cos ϕ= 0.3, break: cos ϕ =0.3)
    AC-15
    Control of electro-magnetic loads of electro-magnets > 72 VA (make: cos ϕ= 0.7, break: cos ϕ= 0.4)
    (1)
    24 V
    (2)
    48 V
    (3)
    115 V
    (4)
    230 V

    DC Loads

    Test conditions: in accordance with standard IEC 947-5-1 set up for rated control voltage.

    DC-12 operating cycles in millions


    DC-12
    Control of resistive loads and isolated solid state loads via optocoupler (L/R ≤ 1 ms)
    (1)
    24 V
    (2)
    48 V
    (3)
    115 V

    DC-13 operating cycles in millions


    DC-13
    Control of electro-magnets (L/R ≤ 2 x (Ue x Ie) in ms, with Ue: rated operating voltage and Ie: rated operating current, with a load protection diode
    (1)
    24 V
    (2)
    48 V
    (3)
    115 V