Ireland
Welcome to the Schneider Electric Website

Welcome to our website.

You can choose another country to view available products or go to our Global website for company information.

Select your location
View all Modicon X80 I/Os
BMEXBP0400 Product picture Schneider Electric

BMEXBP0400

Green premium brand logo
BMEXBP0400 Product picture Schneider Electric
BMEXBP0400
Green premium brand logo

rack X80 - 4 slots - Ethernet backplane

Show more characteristics
Add to My Products Remove from My Products
The maximum number of products that can be compared is 4

  • Main
    range of product
    Modicon X80
    accessory / separate part type
    Rack
    Complementary
    number of slots
    4 bus X + Ethernet
    product compatibility
    I/O module
    BMX processor
    Specific application module
    BMXCPS power supply
    BME processor
    electrical connection
    1 connector (XBE) expansion module
    fixing mode
    By 4 screws - diameter: 4.32…6.35 mm, mounting on panel
    By 4 M6 screws, mounting on plate
    By clips, mounting on 35 mm symmetrical DIN rail
    current consumption
    49 mA at 3.3 V DC
    118 mA at 24 V DC
    MTBF reliability
    2000000 H
    net weight
    0.705 kg
    Environment
    IP degree of protection
    IP20
    ambient air temperature for operation
    0…60 °C
    relative humidity
    5…95 % without condensation
    directives
    2014/35/EU - low voltage directive
    2014/30/EU - electromagnetic compatibility
    2012/19/EU - WEEE directive
    standards
    EN 61131-2
    EN 61000-6-4
    EN 61000-6-2
    EN 61010-2-201
    protective treatment
    TC
    Offer Sustainability
    Sustainable offer status
    Green Premium product
    REACh Regulation
    REACh free of SVHC
    Yes
    EU RoHS Directive
    Pro-active compliance (Product out of EU RoHS legal scope)
    EU RoHS Declaration
    Mercury free
    Yes
    RoHS exemption information
    China RoHS Regulation
    Environmental Disclosure
    Circularity Profile
    WEEE
    The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins
  • View more View less

    Documents

    Language
    • All Languages30
    • English30
    • French10
    Catalogue
    Format
    Size
    Date
    Add to My Documents
    Size pdf
    Size 16.2 MB
    Date 06/08/19
    Size pdf
    Size 11.1 MB
    Date 30/07/19
    User guide
    Format
    Size
    Date
    Add to My Documents
    Modicon M580, Hardware Reference Manual (Version 10)
    Description
    This document provides detailed information about the M580 programmable automation controller (PAC), power supplies, and racks. These topics are also discussed:- Install a local rack in the M580 system.- Configure the M580 CPU.- The CPU performs Ethernet I/O scanning of both RIO and DIO logic without affecting network determinism.
    Size pdf
    Size 12.3 MB
    Date 01/10/19
    Description
    This document provides detailed information about the M580 programmable automation controller (PAC), power supplies, and racks. These topics are also discussed:- Install a local rack in the M580 system.- Configure the M580 CPU.- The CPU performs Ethernet I/O scanning of both RIO and DIO logic without affecting network determinism.
    Modicon M580, Safety System Planning Guide (Version 05)
    Description
    This Safety System Planning Guide describes the modules of the M580 Safety system with special regard to how they meet the Safety requirements of the IEC 61508. It provides detailed information on how to install, run, and maintain the system correctly in order to help protect human beings as well as to help prevent damage to environment, equipment, and production.
    Size pdf
    Size 7.9 MB
    Date 01/09/19
    Description
    This Safety System Planning Guide describes the modules of the M580 Safety system with special regard to how they meet the Safety requirements of the IEC 61508. It provides detailed information on how to install, run, and maintain the system correctly in order to help protect human beings as well as to help prevent damage to environment, equipment, and production.
    Modicon X80 - Racks and Power Supplies, Hardware Reference Manual (Version 03)
    Description
    This document provides detailed information about the Modicon X80 racks and power supplies used for M340 station, M580 system, and X80 drops.
    Size pdf
    Size 3 MB
    Date 01/12/18
    Description
    This document provides detailed information about the Modicon X80 racks and power supplies used for M340 station, M580 system, and X80 drops.
    Modicon M580 - RIO Modules, Installation and Configuration Guide (Version 09)
    Description
    This document describes the adapter modules that can be used in X80 RIO drops. This guide describes 3 adapter modules: - BMECRA31210 - BMXCRA31210 - BMXCRA31200
    Size pdf
    Size 1.7 MB
    Date 01/12/18
    Description
    This document describes the adapter modules that can be used in X80 RIO drops. This guide describes 3 adapter modules: - BMECRA31210 - BMXCRA31210 - BMXCRA31200
    Modicon M580 - Change Configuration on the Fly. User Guide (Version 07)
    Description
    This guide provides information about the Change Configuration on the Fly (CCOTF) feature in a M580 system, using Control Expert software.
    Size pdf
    Size 1.8 MB
    Date 01/12/18
    Description
    This guide provides information about the Change Configuration on the Fly (CCOTF) feature in a M580 system, using Control Expert software.
    Modicon M580 Standalone System Planning Guide for Frequently Used Architectures (Version 09)
    Description
    This document presents one of the PlantStruxure features, using Ethernet as the backbone around the Modicon M580 offer and connecting an M580 local rack and M580 RIO drops. This guide provides detailed information about planning frequently used M580 architectures, including the following: - Ethernet I/O networks (RIO and distributed equipment integrated on the same physical network) - topology rules and recommendations for choosing a network configuration - role of network option switch modules - system commissioning and maintenance - system performance and limitations - system diagnostics
    Size pdf
    Size 18.3 MB
    Date 01/12/18
    Description
    This document presents one of the PlantStruxure features, using Ethernet as the backbone around the Modicon M580 offer and connecting an M580 local rack and M580 RIO drops. This guide provides detailed information about planning frequently used M580 architectures, including the following: - Ethernet I/O networks (RIO and distributed equipment integrated on the same physical network) - topology rules and recommendations for choosing a network configuration - role of network option switch modules - system commissioning and maintenance - system performance and limitations - system diagnostics
    Certificate
    Format
    Size
    Date
    Add to My Documents
    HazLoc by CSA - Class I Division 2 - M340_M580_X80 (Version 1.0)
    Description
    Hazardous location Class I Division 2 by CSA for US and Canada
    Size pdf
    Size 92.9 KB
    Date 23/01/19
    Description
    Hazardous location Class I Division 2 by CSA for US and Canada
    CSA 225844 - M340_M580_X80 (Version 1.0)
    Description
    Ordinary location by CSA for US and Canada
    Size PDF
    Size 242.2 KB
    Date 21/01/19
    Description
    Ordinary location by CSA for US and Canada
    EAC - M340_M580_X80 (Version 1.0)
    Description
    Eurasian Conformity
    Size zip
    Size 2.2 MB
    Date 20/06/18
    Description
    Eurasian Conformity
    Instruction sheet
    Format
    Size
    Date
    Add to My Documents
    Modicon X80 - B800 to X80 I/O Modernization, Instruction Sheet (Version 00)
    Description
    The X80 Automation Series supports a full range of high performance I/O modules designed to interface with a wide variety of field devices. Schneider Electric Services offers a series of conversion products to ease the migration from 800 series I/O to X80 I/O.
    Size pdf
    Size 1.4 MB
    Date 01/04/16
    Description
    The X80 Automation Series supports a full range of high performance I/O modules designed to interface with a wide variety of field devices. Schneider Electric Services offers a series of conversion products to ease the migration from 800 series I/O to X80 I/O.
    Catalogue page
    Format
    Size
    Date
    Add to My Documents
    China RoHS declaration
    Format
    Size
    Date
    Add to My Documents
    rack X80 - 4 slots - Ethernet backplane
    Description
    rack X80 - 4 slots - Ethernet backplane
    Size pdf
    Size 195.3 KB
    Date 15/12/19
    Description
    rack X80 - 4 slots - Ethernet backplane
    Declaration of conformity
    Format
    Size
    Date
    Add to My Documents
    Size pdf
    Size 238.3 KB
    Date 17/10/18
    Description
    RCM
    EU Declaration of Conformity - M340_M580_X80 (Version 1.0)
    Description
    EU Declaration of Conformity
    Size pdf
    Size 3.3 MB
    Date 04/09/18
    Description
    EU Declaration of Conformity
    End of Life Information
    Format
    Size
    Date
    Add to My Documents
    Size pdf
    Size 926.8 KB
    Date 01/07/15
    EU RoHS Declaration
    Format
    Size
    Date
    Add to My Documents
    rack X80 - 4 slots - Ethernet backplane
    Description
    rack X80 - 4 slots - Ethernet backplane
    Size pdf
    Size 195.3 KB
    Date 15/12/19
    Description
    rack X80 - 4 slots - Ethernet backplane
    Marine certificate
    Format
    Size
    Date
    Add to My Documents
    KRS Marine Certificate Modicon M340 X80 PLC (Version 1.0)
    Description
    Korean Register of Shipping
    Size pdf
    Size 563.2 KB
    Date 07/03/19
    Description
    Korean Register of Shipping
    NK Marine Certificate Modicon M340 M580 X80 PLCs (Version 1.0)
    Description
    ClassNK Marine Certificate Modicon M340-M580
    Size pdf
    Size 4.6 MB
    Date 18/02/19
    Description
    ClassNK Marine Certificate Modicon M340-M580
    Size pdf
    Size 317.6 KB
    Date 21/01/19
    Description
    Lloyds Register
    MERCHANT_NAVY_PLC_INSTALLATION (Version 1.0)
    Description
    Merchant navies Installation Instructions
    Size pdf
    Size 181.4 KB
    Date 11/01/19
    Description
    Merchant navies Installation Instructions
    ABS Marine Certificate M340_M580_X80 PLCs (Version 1.0)
    Description
    American Bureau of Shipping
    Size pdf
    Size 678.6 KB
    Date 08/01/19
    Description
    American Bureau of Shipping
    BV Marine Certificate M340_M580_X80 PLCs (Version 1.0)
    Description
    Bureau Veritas - marine certificate for QUANTUM PLCs
    Size pdf
    Size 412.5 KB
    Date 07/01/19
    Description
    Bureau Veritas - marine certificate for QUANTUM PLCs
    CCS_Marine Certificate_M580_M340_X80_PLCs (Version 1.0)
    Description
    China Classification Society
    Size pdf
    Size 896.4 KB
    Date 18/05/18
    Description
    China Classification Society
    DNV-GL_Marine Certificate_Modicon_M340_M580_X80_PLCs (Version 1.0)
    Description
    Det Norske Veritas - Germanischer Lloyd
    Size pdf
    Size 205 KB
    Date 18/05/18
    Description
    Det Norske Veritas - Germanischer Lloyd
    RMRS_Marine Certificate_Modicon_M340_M580_X80_PLCs (Version 1.0)
    Description
    Russian Maritime Register of Shipping
    Size pdf
    Size 3 MB
    Date 18/05/18
    Description
    Russian Maritime Register of Shipping
    Size pdf
    Size 4.3 MB
    Date 04/12/16
    Description
    Registro Italiano Navale
    Product Environmental Profile
    Format
    Size
    Date
    Add to My Documents
    Size pdf
    Size 196 KB
    Date 01/09/14
    REACh Declaration
    Format
    Size
    Date
    Add to My Documents
    rack X80 - 4 slots - Ethernet backplane
    Description
    rack X80 - 4 slots - Ethernet backplane
    Size pdf
    Size 195.3 KB
    Date 15/12/19
    Description
    rack X80 - 4 slots - Ethernet backplane
  • Technical FAQs

    No results found
    Unfortunately, related FAQs are unavailable due to temporary technical issues. Please try again later.
  • Dimensions Drawings

    Dimensions


    Dimensions in mm

    a

    b

    c

    Empty Rack

    Rack With Extender Module Mounted

    242.4

    243.58

    105.11

    NOTE: Overall height is 134.6 with a CPU mounted.

    19

    Dimensions in in.

    a

    b

    c

    Empty Rack

    Rack With Extender Module Mounted

    9.54

    9.59

    4.14

    NOTE: Overall height is 5.30 with a CPU mounted.

    0.75


  • Mounting and Clearance

    Minimum Clearance


    1
    Installation or casing
    2
    Wiring duct or tray
    a
    Side and bottom clearance: > 60 mm (2.36 in.)
    b
    Top clearance: > 80 mm (3.15 in.)


    Mounting a Rack on a DIN rail



    Mounting and Fastening the Rack on Panels


    NOTE: You can use M4, M5, M6, or UNC #6 screws in the fastening holes.

    Dimensions in mm

    a

    b

    202.1

    214.8

    Dimensions in in.

    a

    b

    7.95

    8.45


    Mounting on Telequick Grid AM1-PA and AM3-PA Mounting Grids


    Fasten the rack with four M4, M5, M6 or UNC #6 screws


Compare products: /