
LC1DT60AFD
LC1DT60AFD
TeSys D contactor - 4P(4 NO) - AC-1 - <= 440 V 60 A - 110 V DC standard coil
Show more characteristics-
Characteristics
Main range TeSysproduct name TeSys Dproduct or component type Contactordevice short name LC1Dcontactor application Resistive loadutilisation category AC-1poles description 4Ppower pole contact composition 4 NO[Ue] rated operational voltage Power circuit: <= 690 V AC 25...400 HzPower circuit: <= 300 V DC[Ie] rated operational current 60 A (at <60 °C) at <= 440 V AC AC-1 for power circuitcontrol circuit type DC standard[Uc] control circuit voltage 110 V DCauxiliary contact composition 1 NO + 1 NC[Uimp] rated impulse withstand voltage 6 kV conforming to IEC 60947overvoltage category III[Ith] conventional free air thermal current 10 A (at 60 °C) for signalling circuit60 A (at 60 °C) for power circuitIrms rated making capacity 140 A AC for signalling circuit conforming to IEC 60947-5-1250 A DC for signalling circuit conforming to IEC 60947-5-1800 A at 440 V for power circuit conforming to IEC 60947rated breaking capacity 800 A at 440 V for power circuit conforming to IEC 60947[Icw] rated short-time withstand current 320 A 40 °C - 10 s for power circuit720 A 40 °C - 1 s for power circuit72 A 40 °C - 10 min for power circuit165 A 40 °C - 1 min for power circuit100 A - 1 s for signalling circuit120 A - 500 ms for signalling circuit140 A - 100 ms for signalling circuitassociated fuse rating 10 A gG for signalling circuit conforming to IEC 60947-5-180 A gG at <= 690 V coordination type 1 for power circuit80 A gG at <= 690 V coordination type 2 for power circuitaverage impedance 1.6 mOhm - Ith 60 A 50 Hz for power circuit[Ui] rated insulation voltage Power circuit: 600 V CSA certifiedPower circuit: 600 V UL certifiedSignalling circuit: 690 V conforming to IEC 60947-1Signalling circuit: 600 V CSA certifiedSignalling circuit: 600 V UL certifiedPower circuit: 690 V conforming to IEC 60947-4-1electrical durability 0.7 Mcycles 60 A AC-1 at Ue <= 440 Vpower dissipation per pole 5.8 W AC-1Front cover Withmounting support RailPlatestandards CSA C22.2 No 14EN 60947-4-1EN 60947-5-1IEC 60947-4-1IEC 60947-5-1UL 508product certifications RINABVCSACCCULGOSTGLLROS (Lloyds register of shipping)DNVconnections - terminals Control circuit: screw clamp terminals 2 cable(s) 1…2.5 mm²flexible with cable endControl circuit: screw clamp terminals 1 cable(s) 1…4 mm²flexible without cable endControl circuit: screw clamp terminals 2 cable(s) 1…4 mm²flexible without cable endControl circuit: screw clamp terminals 1 cable(s) 1…4 mm²flexible with cable endControl circuit: screw clamp terminals 1 cable(s) 1…4 mm²solid without cable endControl circuit: screw clamp terminals 2 cable(s) 1…4 mm²solid without cable endPower circuit: screw clamp terminal 1 cable(s) 1…35 mm²flexible without cable endPower circuit: screw clamp terminal 2 cable(s) 1…25 mm²flexible without cable endPower circuit: screw clamp terminal 1 cable(s) 1…35 mm²flexible with cable endPower circuit: screw clamp terminal 2 cable(s) 1…25 mm²flexible with cable endPower circuit: screw clamp terminal 1 cable(s) 1…35 mm²solid without cable endPower circuit: screw clamp terminal 2 cable(s) 1…25 mm²solid without cable endtightening torque Control circuit: 1.7 N.m - on screw clamp terminals - with screwdriver flat Ø 6 mmControl circuit: 1.7 N.m - on screw clamp terminals - with screwdriver Philips No 2Power circuit: 8 N.m - on screw clamp terminals - cable 25…35 mm² hexagonal screw head 4 mmPower circuit: 5 N.m - on screw clamp terminals - cable 1…25 mm² hexagonal screw head 4 mmoperating time 42.5...57.5 ms closing16...24 ms openingsafety reliability level B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1mechanical durability 10 Mcyclesmaximum operating rate 3600 cyc/h 60 °CComplementary coil technology Built-in bidirectional peak limiting diode suppressorcontrol circuit voltage limits 0.1...0.3 Uc (-40…70 °C):drop-out DC0.75...1.25 Uc (-40…60 °C):operational DC1...1.25 Uc (60…70 °C):operational DCtime constant 34 msinrush power in W 19 W (at 20 °C)hold-in power consumption in W 7.4 W at 20 °Cauxiliary contacts type type mechanically linked 1 NO + 1 NC conforming to IEC 60947-5-1 type mirror contact 1 NC conforming to IEC 60947-4-1signalling circuit frequency 25...400 Hzminimum switching current 5 mA for signalling circuitminimum switching voltage 17 V for signalling circuitnon-overlap time 1.5 ms on de-energisation between NC and NO contact1.5 ms on energisation between NC and NO contactinsulation resistance > 10 MOhm for signalling circuitcontact compatibility M7compatibility code LC1DEnvironment IP degree of protection IP20 front face conforming to IEC 60529protective treatment TH conforming to IEC 60068-2-30pollution degree 3ambient air temperature for operation -40…60 °C60…70 °C with deratingambient air temperature for storage -60…80 °Coperating altitude 0...3000 mfire resistance 850 °C conforming to IEC 60695-2-1flame retardance V1 conforming to UL 94mechanical robustness Vibrations contactor open: 2 Gn, 5...300 HzVibrations contactor closed: 4 Gn, 5...300 HzShocks contactor closed: 15 Gn for 11 msShocks contactor open: 10 Gn for 11 msheight 122 mmwidth 70 mmdepth 120 mmnet weight 1.165 kgPacking Units Unit Type of Package 1 PCENumber of Units in Package 1 1Package 1 Weight 1.1 kgPackage 1 Height 7.5 cmPackage 1 width 14 cmPackage 1 Length 15 cmOffer Sustainability Sustainable offer status Green Premium productREACh Regulation REACh free of SVHC YesEU RoHS Directive Compliant
EU RoHS DeclarationToxic heavy metal free YesMercury free YesRoHS exemption information China RoHS Regulation China RoHS declaration
Pro-active China RoHS declaration (out of China RoHS legal scope)Environmental Disclosure Circularity Profile WEEE The product must be disposed on European Union markets following specific waste collection and never end up in rubbish binsPVC free YesContractual warranty Warranty 12 months -
View more
Documents
Language- All Languages13
- English13
- Chinese3
- French4
- German3
- Italian3
- Portuguese3
- Russian3
- Spanish3
CatalogueFormatSizeDateAdd to My DocumentsTeSys - Catalogue 2020 - Innovative and connected solutions for motor starters (Version 10.0)DescriptionReady-to-use motor starters and all components for building specific motor starters ( circuit breakers, contactors, overload relays , accessories ...). This edition includes a presentation of the new TeSys island system. The catalogue can also be downloaded chapter per chapter.prp.document.label.format pdfSize 118.2 MBDate 7/22/20DescriptionReady-to-use motor starters and all components for building specific motor starters ( circuit breakers, contactors, overload relays , accessories ...). This edition includes a presentation of the new TeSys island system. The catalogue can also be downloaded chapter per chapter.TeSys catalogue - 2020 - chapter B8 contactors TeSys SK,K, D, SKGC, GC, GY,GF (Version 8.0)DescriptionContactors : TeSys D.Mini contactors, pre cabled reversing contactors : TeSys SK, KModular (on DIN rail) contactors, dual tariif contactors, impulse relays :TeSys SKGC, GC, GY, GFAccessoriesprp.document.label.format pdfSize 16.1 MBDate 7/22/20DescriptionContactors : TeSys D.Mini contactors, pre cabled reversing contactors : TeSys SK, KModular (on DIN rail) contactors, dual tariif contactors, impulse relays :TeSys SKGC, GC, GY, GFAccessoriesTeSys catalogue - 2020 - chapter A6 - Circuit breaker + contactor coordination tables and design guidelines (Version 7.0)DescriptionCoordination between protection & control components; Suggested coordinated DOL motor starters combinations; Suggested coordinated Star-delta motor starters combinations;Contactors : utilization categories; standard characteristics, sel. tables per categories Contactors for specific application; standards, protection against contact, protective treatments Included : TeSys island coordination tablesprp.document.label.format pdfSize 3.7 MBDate 7/22/20DescriptionCoordination between protection & control components; Suggested coordinated DOL motor starters combinations; Suggested coordinated Star-delta motor starters combinations;Contactors : utilization categories; standard characteristics, sel. tables per categories Contactors for specific application; standards, protection against contact, protective treatments Included : TeSys island coordination tablesCADFormatSizeDate