Welcome to the Schneider Electric Website

You can visit our website in another country or region or go to our global website.

Select your location

Welcome the the Schneider Electric French website. It looks like you are located in the United States, would you like to change your location?

Traduisez en francais
View all   Smart-UPS VT
SUVTP30KH4B4 Product picture Schneider Electric
Restricted Sales for Services

SUVTP30KH4B4

Product Logo
SUVTP30KH4B4 Product picture Schneider Electric
Restricted Sales for Services
SUVTP30KH4B4
Product Logo

APC Smart-UPS VT 30KVA 400V w/4 Batt Mod Exp to 4, Int Maint Bypass, Parallel Capable

Show more characteristics
Commercial status
Discontinued on 31 December 2020
To be end-of-service on 31 December 2030
The maximum number of products that can be compared is 4. Remove already added products.

SUVTP30KH4B4 is replaced by:
Product
Qty
SUVTP30KH4B4S
Qty
1
The maximum number of products that can be compared is 4. Remove already added products.
  • Migration SPD
1
  • Overview
    Lead time
    Special Order - Call for Quoted Lead Times
    General
    provided equipment
    Battery modules ship installed
    Bolt down brackets
    CD with software
    Installation guide
    Power modules ship installed
    User manual
    Web/SNMP management card
    performance multiplier
    1
    Number of tare power
    360 W
    Number of power module free slots
    0
    Number of power module filled slots
    1
    redundant
    Yes
    size UPS version
    Internetworking
    Server
    Telecom
    UPS size
    L
    value multiplier
    1
    Physical
    colour
    Black
    depth
    83.8 cm
    height
    149 cm
    mounting location
    Front
    mounting preference
    No preference
    net weight
    629.09 kg
    mounting mode
    Not rack-mountable
    USB compatible
    No
    width
    52.3 cm
    Input
    network frequency
    47...70 Hz auto-sensing
    number of input connectors
    1 hard wire 5-wire (3P + N + E)
    input voltage limits
    304...477 V
    inputvolt_other
    380 V
    415 V
    maximum input current
    41 A
    switching current capacity
    63 A
    input voltage
    400 V 3 phases
    load power factor
    0.5 leading to 0.5 lagging
    cos phi
    0.98
    Output
    rated power in W
    24000 W
    Maximum configurable power in W
    24000 W
    harmonic distortion
    Less than 5 % at full load
    output frequency
    47...53 Hz for 50 Hz nominal sync to mains
    50 Hz +/- 0.1 % for 50 Hz nominal unsynchronised
    outputvolt_other
    380 V
    415 V
    crest factor
    Unlimited
    UPS type
    Double conversion online
    Wave type
    Sine wave
    connections - terminals
    1 screw terminals
    output connector type
    Hard wire 4-wire (3P + E) 1
    Hard wire 5-wire (3P + N + E) 1
    output overload operation
    10 minutes at 125% and 60 seconds at 150%
    bypass type
    Built-in maintenance bypass
    Built-in static bypass
    curve equation
    Efficiency
    curve fixed loss
    0.01
    curve load maximum
    100 %
    curve load minimum
    2 %
    curve proportional loss
    0.0176
    curve square loss
    0.0134
    curve X-axis maximum
    100 %
    curve test cond ID
    Curve fit to measured efficiency data. All measurements taken in normal operating mode, at typical environmental conditions, with nominal electrical input and balanced PF = 0.8 output.
    curve X-axis minimum
    0 %
    curve X-axis title
    Load
    curve X-axis units
    Percentage
    curve Y-axis maximum
    100 %
    curve Y-axis minimum
    50 %
    curve Y-axis title
    Efficiency
    curve Y-axis units
    Percentage
    efficiency
    95.8 % (full load)
    95.5 % (half load)
    graph display
    1
    maximum output current
    48 A
    output voltage
    230 V
    400 V 3 phases
    Maximum configurable power in VA
    30000 VA
    rated power in VA
    30000 VA
    Conformance
    product certifications
    C-Tick
    CE
    standards
    EN 50091-2
    EN/IEC 62040-3
    IEC 61000-3-2
    IEC 61000-3-3
    ISO 14001
    ISO 9001
    VFI-SS-112
    Environmental
    ambient air temperature for operation
    0…40 °C
    relative humidity
    0…95 %
    operating altitude
    0...3333 ft
    ambient air temperature for storage
    -15…45 °C
    Storage Relative Humidity
    0…95 %
    storage altitude
    0.00…15240.00 m
    acoustic level
    58 dBA
    heat dissipation
    3685 Btu/h
    show note OP temperature
    No
    IP degree of protection
    IP20
    Batteries & Runtime
    battery type
    Lead-acid battery
    number of battery filled slots
    4
    number of battery free slots
    0
    Battery recharge time
    5 h
    number of battery replacement quantity
    4
    additional information
    Configurable for 380 : 400 or 415 V 3 Phase nominal output voltage
    liquid value
    0
    discharge battery voltage
    +/- 154 V
    battery curve