India
Welcome to the Schneider Electric Website

Welcome to our website.

You can choose another country to view available products or go to our Global website for company information.

Select your location
View all Modicon Momentum
171CCC78010 Product picture Schneider Electric

171CCC78010

171CCC78010 Product picture Schneider Electric
171CCC78010

M1/M1E processor adaptor - 2 Modbus - 32 MHz

Show more characteristics
Add to My Products Remove from My Products
The maximum number of products that can be compared is 4

  • Main
    range of product
    Modicon Momentum automation platform
    product or component type
    M1/M1E processor adaptor
    software designation
    Concept version V2.6
    Modsoft version >= V2.5
    ProWORX NxT version V2.0
    ProWORX 32
    communication port protocol
    Modbus
    processor name
    X 86 based (INTEL, AMD)
    clock frequency
    32 MHz
    Complementary
    discrete I/O processor capacity
    8192 I/8192 O
    memory type
    512 kB flash
    512 kB RAM
    memory description
    Program memory 18 kB LL984
    Program memory 240 kB IEC
    Data 24 kB
    material
    Lexan
    word length
    16 bit
    [Us] rated supply voltage
    5.0 V DC +/-5 %
    supply
    By Momentum I/O base
    exact time for 1 Kinstruction
    1 ms
    register I/O processor capacity
    26048 I/26048 O
    I/O limit processor capacity
    I/O local on Modbus
    number of port
    1 RS232C non isolated
    1 RS485
    marking
    CE
    net weight
    0.042 kg
    Environment
    protective treatment
    TC
    ambient air temperature for operation
    0…60 °C
    ambient air temperature for storage
    -40…85 °C
    relative humidity
    5…96 % without condensation
    operating altitude
    2000 m
    shock resistance
    <= 15 gn peak 11 ms half sine wave acceleration
    vibration resistance
    0.75 mm d.a
    1 gn
    product certifications
    Nema type 250
    CUL
    UL
    FM Class 1 Division 2
    Contractual warranty
    Warranty
    18 months
  • View more View less

    Documents

    Language
    • English1
    User guide
    Format
    Size
    Date
    Add to My Documents
    171CCC... / 171CCS... M1 Processor Adapter and Option Adapter (Version 10)
    Description
    This manual contains complete information about the Momentum M1 processor adapters, option adapters and Ethernet adapters. It does not contain information about Momentum I/O bases or communication adapters.
    Size pdf
    Size 3.6 MB
    Date 1/4/10
    Description
    This manual contains complete information about the Momentum M1 processor adapters, option adapters and Ethernet adapters. It does not contain information about Momentum I/O bases or communication adapters.
  • View more View less

    Software and Firmware

    Language
    • English2
    Firmware - Updates
    Format
    Size
    Date
    Add to My Documents
    171CCC78010 Momentum M1 IEC Exec.(8/2008) (Version 2.11)
    Files in document
    bin
    240 KB
    bin
    240 KB
    bin
    240 KB
    bin
    240 KB
    bin
    240 KB
    bin
    240 KB
    Description
    ****IEC Exec. v.2.11 Reference Resolution - TBD 1) Exec version 2.11 did not allow OFS to access Concept IEC unlocated variables. 2) An xxmit Function Block may fault with an error 150 if the xxmit block is active (powered) while the 171CBB97030 is powered cycled. ****IEC Exec. v.2.10 Released with Concept 2.6 SR2 ****IEC Exec. v.2.08 Reference Resolution #8089 1) A 40xxx register may get set to zero when the M1 is put into Run mode. 2) An M1 may crash after a start command if used with a 172JNN21032 Option Adapter. Use file m1iv208e.bin for Concept 2.5 SR2 & Concept 2.6 ONLY. ****IEC Exec. v.2.07 (Not Released) ****IEC Exec. v.2.06 Reference Resolution #1186 1) Minimum Exec. required for M1 171CCS76000 processors at PV02. 2) Exec changed so the battery low coil only indicates that the memory battery backup voltage is <2.68 volts and should be changed within 30 days. It will not cause the processor to go into a not configured state at power up as in earlier Exec. revisions. For Concept 2.1 B2.1, use file m1iv206b.bin For Concept 2.2 SR2, use file m1v206c.bin For Concept 2.5 SR2, use file m1iv206d.bin
    Size zip
    Size 1.4 MB
    Date 4/1/05
    Files in document
    bin
    240 KB
    bin
    240 KB
    bin
    240 KB
    bin
    240 KB
    bin
    240 KB
    bin
    240 KB
    Description
    ****IEC Exec. v.2.11 Reference Resolution - TBD 1) Exec version 2.11 did not allow OFS to access Concept IEC unlocated variables. 2) An xxmit Function Block may fault with an error 150 if the xxmit block is active (powered) while the 171CBB97030 is powered cycled. ****IEC Exec. v.2.10 Released with Concept 2.6 SR2 ****IEC Exec. v.2.08 Reference Resolution #8089 1) A 40xxx register may get set to zero when the M1 is put into Run mode. 2) An M1 may crash after a start command if used with a 172JNN21032 Option Adapter. Use file m1iv208e.bin for Concept 2.5 SR2 & Concept 2.6 ONLY. ****IEC Exec. v.2.07 (Not Released) ****IEC Exec. v.2.06 Reference Resolution #1186 1) Minimum Exec. required for M1 171CCS76000 processors at PV02. 2) Exec changed so the battery low coil only indicates that the memory battery backup voltage is <2.68 volts and should be changed within 30 days. It will not cause the processor to go into a not configured state at power up as in earlier Exec. revisions. For Concept 2.1 B2.1, use file m1iv206b.bin For Concept 2.2 SR2, use file m1v206c.bin For Concept 2.5 SR2, use file m1iv206d.bin
    171CCC78010 Momentum M1 984LL Exec.(2/26/03) (Version 2.07)
    Files in document
    bin
    192 KB
    bin
    192 KB
    bin
    192 KB
    bin
    192 KB
    bin
    192 KB
    bin
    192 KB
    bin
    192 KB
    Description
    Exec. v.2.07 (m1llv207.bin) 1) Fixes a 40xxx register value setting to zero on a start command. Exec. v.2.06 (m1llv206.bin) 1) Minimum Exec. required for M1 171CCS76000 processors at PV02. Exec. v.2.05 (m1llv205.bin) 1) Fixes problem in Exec. v.2.04 where M1 would not go into Run. 2) The processor will not go into a not configured state after a power cycle if a battery low condition exists (less than 2.68 volts). 3) Fixes XMIT Function Block operation over 2-wire RS485. Exec. v.2.04 (m1llv204.bin) EXEC. v.2.04 WILL NOT WORK IN M1 PROCESSORS. Putting a program into Run mode causes the Run LED to flash in a pattern of 4. It has been removed from the Exec. listing. Refer to Resolution #1096. Exec. v.2.03 (m1v203.bin) 1) Allows the I/O Bus to be more tolerant of PCP devices (example:ATV58) on the network. Exec. v.2.02 (m1exv202.bin) 1) Changes the response of 4 bi-directional IO Bases in the event of an output fault 2) Allows IO Bus network fault monitoring. Exec. v.2.01 (m1ev201.bin) 1) Fixes M1 processors failing with stopped error code 4 when doing online programming changes. Exec. v.2.00 (m1exe200.bin) 1) The XMIT function block is included in the exec. 2) Allows ASCII read & write
    Size zip
    Size 1.3 MB
    Date 27/2/03
    Files in document
    bin
    192 KB
    bin
    192 KB
    bin
    192 KB
    bin
    192 KB
    bin
    192 KB
    bin
    192 KB
    bin
    192 KB
    Description
    Exec. v.2.07 (m1llv207.bin) 1) Fixes a 40xxx register value setting to zero on a start command. Exec. v.2.06 (m1llv206.bin) 1) Minimum Exec. required for M1 171CCS76000 processors at PV02. Exec. v.2.05 (m1llv205.bin) 1) Fixes problem in Exec. v.2.04 where M1 would not go into Run. 2) The processor will not go into a not configured state after a power cycle if a battery low condition exists (less than 2.68 volts). 3) Fixes XMIT Function Block operation over 2-wire RS485. Exec. v.2.04 (m1llv204.bin) EXEC. v.2.04 WILL NOT WORK IN M1 PROCESSORS. Putting a program into Run mode causes the Run LED to flash in a pattern of 4. It has been removed from the Exec. listing. Refer to Resolution #1096. Exec. v.2.03 (m1v203.bin) 1) Allows the I/O Bus to be more tolerant of PCP devices (example:ATV58) on the network. Exec. v.2.02 (m1exv202.bin) 1) Changes the response of 4 bi-directional IO Bases in the event of an output fault 2) Allows IO Bus network fault monitoring. Exec. v.2.01 (m1ev201.bin) 1) Fixes M1 processors failing with stopped error code 4 when doing online programming changes. Exec. v.2.00 (m1exe200.bin) 1) The XMIT function block is included in the exec. 2) Allows ASCII read & write
  • Technical FAQs

    No results found.
    Unfortunately, related FAQs are unavailable due to temporary technical issues. Please try again later.
Compare products: /