India
Welcome to the Schneider Electric Website

Welcome to our website.

You can choose another country to view available products or go to our Global website for company information.

Select your location
View all Altivar 32
ATV32HU15M2 Product picture Schneider Electric

ATV32HU15M2

Green premium brand logo
ATV32HU15M2 Product picture Schneider Electric
ATV32HU15M2
Green premium brand logo

variable speed drive ATV32 - 1.5 kw - 200 V - 1 phase - with heat sink

Show more characteristics
Add to My Products Remove from My Products
The maximum number of products that can be compared is 4

  • Main
    range of product
    Altivar 32
    product or component type
    Variable speed drive
    product destination
    Asynchronous motors
    Synchronous motors
    product specific application
    Complex machines
    function available
    -
    assembly style
    With heat sink
    component name
    ATV32
    EMC filter
    Class C2 EMC filter integrated
    network number of phases
    1 phase
    [Us] rated supply voltage
    200...240 V - 15...10 %
    supply voltage limits
    170…264 V
    supply frequency
    50...60 Hz - 5...5 %
    network frequency
    47.5...63 Hz
    motor power kW
    1.5 kW at 200...240 V
    motor power hp
    2 hp at 200...240 V
    Complementary
    line current
    14.8 A for 240 V 1 phase 1.5 kW / 2 hp
    17.6 A for 200 V 1 phase 1.5 kW / 2 hp
    apparent power
    3.6 kVA at 240 V 1 phase 1.5 kW / 2 hp
    prospective line Isc
    1 kA for 1 phase
    nominal output current
    8 A at 4 kHz 240 V 1.5 kW / 2 hp
    maximum transient current
    12 A for 60 s 1.5 kW / 2 hp
    output frequency
    0.0005…0.599 kHz
    nominal switching frequency
    4 kHz
    switching frequency
    2...16 kHz adjustable
    speed range
    1…100 for asynchronous motor in open-loop mode
    speed accuracy
    +/- 10 % of nominal slip 0.2 Tn to Tn
    torque accuracy
    +/- 15 %
    transient overtorque
    170…200 %
    braking torque
    <= 170 % with braking resistor
    asynchronous motor control profile
    Voltage/frequency ratio, 5 points
    Flux vector control without sensor, standard
    Voltage/frequency ratio, 2 points
    Voltage/frequency ratio - Energy Saving, quadratic U/f
    Flux vector control without sensor - Energy Saving, NoLoad law
    synchronous motor control profile
    Vector control without sensor
    regulation loop
    Adjustable PID regulator
    motor slip compensation
    Adjustable 0...300 %
    Not available in voltage/frequency ratio (2 or 5 points)
    Automatic whatever the load
    local signalling
    1 LED red for drive voltage
    1 LED green for CANopen run
    1 LED red for CANopen error
    1 LED red for drive fault
    output voltage
    <= power supply voltage
    noise level
    43 dB conforming to 86/188/EEC
    insulation
    Electrical between power and control
    electrical connection
    Screw terminal, clamping capacity: 0.5...1.5 mm², AWG 18...AWG 14 (control)
    Removable screw terminals, clamping capacity: 1.5...2.5 mm², AWG 14...AWG 12 (motor/braking resistor)
    Screw terminal, clamping capacity: 2.5...4 mm², AWG 12...AWG 10 (power supply)
    tightening torque
    0.5 N.m, 4.4 lb/ft (control)
    0.7 N.m, 7.1 lb/ft (motor/braking resistor)
    0.6 N.m, 5.3 lb/ft (power supply)
    supply
    Internal supply for reference potentiometer (1 to 10 kOhm): 10.5 V DC +/- 5 %, <10 mA, protection type: overload and short-circuit protection
    analogue input number
    3
    analogue input type
    AI1 voltage: 0...10 V DC, impedance: 30000 Ohm, resolution 10 bits
    AI2 bipolar differential voltage: +/- 10 V DC, impedance: 30000 Ohm, resolution 10 bits
    AI3 current: 0...20 mA (or 4-20 mA, x-20 mA, 20-x mA or other patterns by configuration), impedance: 250 Ohm, resolution 10 bits
    sampling duration
    2 ms (AI1, AI2, AI3) - analog input(s)
    2 ms (AO1) - analog input(s)
    response time
    LI1...LI6 8 ms, tolerance +/- 0.7 ms for logic output(s)
    R1A, R1B, R1C 2 ms for relay output(s)
    R2A, R2C 2 ms for relay output(s)
    accuracy
    +/- 0.2 % (AI1, AI2, AI3) for a temperature of -10...60 °C
    +/- 0.5 % (AI1, AI2, AI3) for a temperature of 25 °C
    +/- 1 % (AO1) for a temperature of 25 °C
    +/- 2 % (AO1) for a temperature of -10...60 °C
    linearity error
    +/- 0.2...0.5 % of maximum value (AI1, AI2, AI3)
    +/- 0.3 % (AO1)
    analogue output number
    1
    analogue output type
    AO1 software-configurable current 0...20 mA, impedance: 800 Ohm, resolution 10 bits
    AO1 software-configurable voltage 0...10 V, impedance: 470 Ohm, resolution 10 bits
    discrete output number
    3
    discrete output type
    Configurable relay logic: (R1A, R1B, R1C) NO/NC - 100000 cycles
    Configurable relay logic: (R2A, R2B) NO - 100000 cycles
    Logic: (LO)
    minimum switching current
    5 mA at 24 V DC for configurable relay logic
    maximum switching current
    R1: 3 A at 250 V AC resistive load, cos phi = 1
    R1: 4 A at 30 V DC resistive load, cos phi = 1
    R1, R2: 2 A at 250 V AC inductive load, cos phi = 0.4
    R1, R2: 2 A at 30 V DC inductive load, cos phi = 0.4
    R2: 5 A at 250 V AC resistive load, cos phi = 1
    R2: 5 A at 30 V DC resistive load, cos phi = 1
    discrete input number
    7
    discrete input type
    Programmable (sink/source) (LI1...LI4)24...30 V DC, with level 1 PLC
    Programmable as pulse input 20 kpps (LI5)24...30 V DC, with level 1 PLC
    Switch-configurable PTC probe (LI6)24...30 V DC
    Safe torque off (STO)24...30 V DC - 1500 Ohm
    discrete input logic
    Negative logic (sink) (LI1...LI6), > 19 V (state 0), < 13 V (state 1)
    Positive logic (source) (LI1...LI6), < 5 V (state 0), > 11 V (state 1)
    acceleration and deceleration ramps
    Ramp switching
    CUS
    S
    Deceleration ramp automatic stop DC injection
    Linear
    Deceleration ramp adaptation
    U
    braking to standstill
    By DC injection
    protection type
    Input phase breaks: drive
    Overcurrent between output phases and earth: drive
    Overheating protection: drive
    Short-circuit between motor phases: drive
    Thermal protection: drive
    communication port protocol
    CANopen
    Modbus
    connector type
    1 RJ45 (on front face) for Modbus/CANopen
    physical interface
    2-wire RS 485 for Modbus
    transmission frame
    RTU for Modbus
    type of polarization
    No impedance for Modbus
    number of addresses
    1…127 for CANopen
    1…247 for Modbus
    method of access
    Slave CANopen
    electromagnetic compatibility
    1.2/50 µs - 8/20 µs surge immunity test, level 3 conforming to IEC 61000-4-5
    Conducted radio-frequency immunity test, level 3 conforming to IEC 61000-4-6
    Electrical fast transient/burst immunity test, level 4 conforming to IEC 61000-4-4
    Electrostatic discharge immunity test, level 3 conforming to IEC 61000-4-2
    Radiated radio-frequency electromagnetic field immunity test, level 3 conforming to IEC 61000-4-3
    Voltage dips and interruptions immunity test conforming to IEC 61000-4-11
    width
    60 mm
    height
    325 mm
    depth
    245 mm
    net weight
    2.9 kg
    option card
    Communication card for CANopen daisy chain
    Communication card for CANopen open style
    Communication card for DeviceNet
    Communication card for Ethernet/IP
    Communication card for Profibus DP V1
    Environment
    standards
    EN 61800-3 environments 2 category C2
    EN/IEC 61800-5-1
    EN 61800-3 environments 1 category C2
    EN/IEC 61800-3
    EN 55011 class A group 1
    product certifications
    UL
    GOST
    NOM 117
    CSA
    C-Tick
    marking
    CE
    pollution degree
    2 conforming to EN/IEC 61800-5-1
    IP degree of protection
    IP20 conforming to EN/IEC 61800-5-1
    vibration resistance
    1 gn (f = 13…200 Hz) conforming to EN/IEC 60068-2-6
    1.5 mm peak to peak (f = 3…13 Hz) conforming to EN/IEC 60068-2-6
    shock resistance
    15 gn for 11 ms conforming to EN/IEC 60068-2-27
    relative humidity
    5…95 % without condensation conforming to IEC 60068-2-3
    5…95 % without dripping water conforming to IEC 60068-2-3
    ambient air temperature for operation
    -10…50 °C without
    50…60 °C with derating factor
    ambient air temperature for storage
    -25…70 °C
    operating altitude
    <= 1000 m without
    1000...2000 m with current derating 1 % per 100 m
    operating position
    Vertical +/- 10 degree
    Offer Sustainability
    Sustainable offer status
    Green Premium product
    REACh Regulation
    EU RoHS Directive
    Pro-active compliance (Product out of EU RoHS legal scope)
    EU RoHS Declaration
    Mercury free
    Yes
    RoHS exemption information
    China RoHS Regulation
    Environmental Disclosure
    Circularity Profile
    WEEE
    The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins
    Contractual warranty
    Warranty
    18 months
  • View more View less

    Documents

    Language
    • All Languages24
    • English24
    • Chinese4
    Catalogue
    Format
    Size
    Date
    Add to My Documents
    Size pdf
    Size 4.1 MB
    Date 21/5/15
    User guide
    Format
    Size
    Date
    Add to My Documents
    ATV32: safety integrated functions manual (Version 07)
    Description
    The safety functions in Altivar32, allow you to develop applications oriented in the protection of man and machine. The safety functions are configured with SoMove software. The content of this manual is also accessible through the ATV32 DTM online help.
    Size pdf
    Size 4.9 MB
    Date 31/1/17
    Description
    The safety functions in Altivar32, allow you to develop applications oriented in the protection of man and machine. The safety functions are configured with SoMove software. The content of this manual is also accessible through the ATV32 DTM online help.
    BMP Synchronous Motor manual (Version 1.3)
    Description
    ATV32, ATV320
    Size pdf
    Size 1 MB
    Date 31/1/17
    Description
    ATV32, ATV320
    Size xlsx
    Size 203.9 KB
    Date 18/6/15
    Description
    Soft V2.5
    Size pdf
    Size 2 MB
    Date 31/7/14
    ATV32 Quick Start Annex: SCCR (Version 02)
    Description
    Short Circuit Current Ratings (SCCR) and branch circuit protection The combinations in the table have been tested per UL508C. (Reference UL file E116875)
    Size pdf
    Size 124.1 KB
    Date 31/1/14
    Description
    Short Circuit Current Ratings (SCCR) and branch circuit protection The combinations in the table have been tested per UL508C. (Reference UL file E116875)
    Size pdf
    Size 4.2 MB
    Date 31/10/13
    CAD
    Format
    Size
    Date
    Add to My Documents
    CAD for ATV32HU15M2: variable speed drive ATV32 - 1.5 kw - 200 V - 1 phase - with heat sink (Version 1.0)
    Description
    You will be redirected to the ThomasNet website. Then you could download this CAD model in more than 15 different 2D or 3D CAD formats.
    CAD for ATV32HU15M2: variable speed drive ATV32 - 1.5 kw - 200 V - 1 phase - with heat sink (Version 1.0)
    Description
    You will be redirected to the ThomasNet website. Then you could download this CAD model in more than 15 different 2D or 3D CAD formats.
    CAD file (on TraceParts) for ATV32HU15M2: variable speed drive ATV32 - 1.5 kw - 200 V - 1 phase - with heat sink (Version 2.0)
    Description
    You will be redirected to the Traceparts website. Register for free or log in to your Traceparts account to download more than 15 different 2D or 3D CAD formats.
    CAD file (on TraceParts) for ATV32HU15M2: variable speed drive ATV32 - 1.5 kw - 200 V - 1 phase - with heat sink (Version 2.0)
    Description
    You will be redirected to the Traceparts website. Register for free or log in to your Traceparts account to download more than 15 different 2D or 3D CAD formats.
    Certificate
    Format
    Size
    Date
    Add to My Documents
    Size pdf
    Size 930 KB
    Date 17/6/19
    Size pdf
    Size 972.6 KB
    Date 28/5/19
    Size pdf
    Size 5.8 MB
    Date 19/3/19
    Size pdf
    Size 42.2 KB
    Date 9/5/18
    Size pdf
    Size 219.2 KB
    Date 1/11/16
    Size pdf
    Size 803 KB
    Date 2/2/16
    Size pdf
    Size 384.6 KB
    Date 6/11/15
    Size pdf
    Size 60.1 KB
    Date 26/7/11
    Instruction sheet
    Format
    Size
    Date
    Add to My Documents
    Instruction Sheet - ATV320/32 Fan Kit (Version 02)
    Description
    VZ3V32C100, VZ3V32D100, VZ3V32A100, VZ3V32B100, VZ3V303S2001, VZ3V303S3001
    Size pdf
    Size 3.9 MB
    Date 17/6/16
    Description
    VZ3V32C100, VZ3V32D100, VZ3V32A100, VZ3V32B100, VZ3V303S2001, VZ3V303S3001
    End of Life Information
    Format
    Size
    Date
    Add to My Documents
    Size pdf
    Size 573.9 KB
    Date 1/3/09
    EU RoHS Declaration
    Format
    Size
    Date
    Add to My Documents
    variable speed drive ATV32 - 1.5 kw - 200 V - 1 phase - with heat sink
    Description
    variable speed drive ATV32 - 1.5 kw - 200 V - 1 phase - with heat sink
    Size pdf
    Size 195.3 KB
    Date 14/11/19
    Description
    variable speed drive ATV32 - 1.5 kw - 200 V - 1 phase - with heat sink
    Product Environmental Profile
    Format
    Size
    Date
    Add to My Documents
    Instruction Sheet: China RoHS - Hazardous Substances Table (Version 01)
    Description
    This table is made according to SJ/T 11364. O: indicates that the concentration of hazardous substance in all of the homogeneous materials for this part is below the limit as stipulated in GB/T 26572. X: indicates that concentration of hazardous substance in at least one of the homogeneous materials used for this part is above the limit as stipulated in GB/T 26572
    Size pdf
    Size 1.1 MB
    Date 30/5/16
    Description
    This table is made according to SJ/T 11364. O: indicates that the concentration of hazardous substance in all of the homogeneous materials for this part is below the limit as stipulated in GB/T 26572. X: indicates that concentration of hazardous substance in at least one of the homogeneous materials used for this part is above the limit as stipulated in GB/T 26572
    Size pdf
    Size 882.4 KB
    Date 30/6/10
    REACh Declaration
    Format
    Size
    Date
    Add to My Documents
    variable speed drive ATV32 - 1.5 kw - 200 V - 1 phase - with heat sink
    Description
    variable speed drive ATV32 - 1.5 kw - 200 V - 1 phase - with heat sink
    Size pdf
    Size 195.3 KB
    Date 14/11/19
    Description
    variable speed drive ATV32 - 1.5 kw - 200 V - 1 phase - with heat sink
    RoHs China Declaration
    Format
    Size
    Date
    Add to My Documents
    variable speed drive ATV32 - 1.5 kw - 200 V - 1 phase - with heat sink
    Description
    variable speed drive ATV32 - 1.5 kw - 200 V - 1 phase - with heat sink
    Size pdf
    Size 195.3 KB
    Date 14/11/19
    Description
    variable speed drive ATV32 - 1.5 kw - 200 V - 1 phase - with heat sink
  • View more View less

    Software and Firmware

    Language
    • English10
    EDS files
    Format
    Size
    Date
    Add to My Documents
    POWERLINK XDD VW3A3619 (Version 1.2.1)
    Description
    on ATV32, ATV320, ATV340, ATV600, ATV900
    Size zip
    Size 106.6 KB
    Date 6/12/18
    Description
    on ATV32, ATV320, ATV340, ATV600, ATV900
    Size zip
    Size 51.7 KB
    Date 6/12/18
    Size zip
    Size 143.3 KB
    Date 18/5/18
    Size zip
    Size 25.2 KB
    Date 23/6/17
    Size zip
    Size 53.7 KB
    Date 30/8/16
    Size zip
    Size 70.5 KB
    Date 30/8/16
    Size zip
    Size 155.4 KB
    Date 30/8/16
    Size zip
    Size 25.2 KB
    Date 18/6/15
    GSD files
    Format
    Size
    Date
    Add to My Documents
    Size zip
    Size 32.8 KB
    Date 19/7/19
    Size zip
    Size 74 KB
    Date 1/10/18
  • Technical FAQs

    No results found.
    Unfortunately, related FAQs are unavailable due to temporary technical issues. Please try again later.
  • Dimensions Drawings

    Size B
    Dimensions



  • Mounting and Clearance

    Mounting and Clearance


    (1)
    Minimum value corresponding to thermal constraints. A 150 mm clearance may help to connect the ground.
    (2)
    Optional GV2 circuit-breaker


    Option: Protection Device, GV2 circuit-breaker

    The drive is prepared to be equipped with an optional GV2 circuit-breaker.

    The GV2 circuit-breaker is directly mounted on the drive. Mechanical and electrical link are made using the optional adapter. The options are supplied with detailed mounting instruction sheet.

    NOTE: The product overall dimension, including GV2 adapter and EMC plate mounted, becomes 424 mm (16.7 in.)


    (1)
    Ground screw (HS type 2 - 5x12)


  • Connections and Schema

    Connection Diagrams
    Single or Three-phase Power Supply - Diagram with Line Contactor

    Connection diagrams conforming to standards EN 954-1 category 1 and IEC/EN 61508 capacity SIL1, stopping category 0 in accordance with standard IEC/EN 60204-1.


    (1)
    Line choke (if used)
    (3)
    Fault relay contacts, for remote signaling of drive status

    Single or Three-phase Power Supply - Diagram with Switch Disconnect

    Connection diagrams conforming to standards EN 954-1 category 1 and IEC/EN 61508 capacity SIL1, stopping category 0 in accordance with standard IEC/EN 60204-1.


    (1)
    Line choke (if used)
    (3)
    Fault relay contacts, for remote signaling of drive status

    Diagram with Preventa Safety Module (Safe Torque Off Function)

    Connection diagrams conforming to standards EN 954-1 category 3 and IEC/EN 61508 capacity SIL2, stopping category 0 in accordance with standard IEC/EN 60204-1.

    When the emergency stop is activated, the drive power supply is cut immediately and the motor stops in freewheel, according to category 0 of standard IEC/EN 60204-1.

    A contact on the Preventa XPS AC module must be inserted in the brake control circuit to engage it safely when the STO (Safe Torque Off) safety function is activated.


    (1)
    Line choke (if used)
    (2)
    It is essential to connect the shielding to the ground.
    (3)
    Fault relay contacts, for remote signaling of drive status

    The STO safety function integrated into the product can be used to implement an "EMERGENCY STOP" (IEC 60204-1) for category 0 stops.

    With an additional, approved EMERGENCY STOP module, it is also possible to implement category 1 stops.

    STO function

    The STO safety function is triggered via 2 redundant inputs. The circuits of the two inputs must be separate so that there are always two channels. The switching process must be simultaneous for both inputs (offset < 1 s).

    The power stage is disabled and an error message is generated. The motor can no longer generate torque and coasts down without braking. A restart is possible after resetting the error message with a "Fault Reset".

    The power stage is disabled and an error message is generated if only one of the two inputs is switched off or if the time offset is too great. This error message can only be reset by switching off the product.

    Diagram without Preventa Safety Module

    Connection diagrams conforming to standards EN 954-1 category 2 and IEC/EN 61508 capacity SIL1, stopping category 0 in accordance with standard IEC/EN 60204-1.

    The connection diagram below is suitable for use with machines with a short freewheel stop time (machines with low inertia or high resistive torque).

    When the emergency stop is activated, the drive power supply is cut immediately and the motor stops in freewheel, according to category 0 of standard IEC/EN 60204-1.


    (1)
    Line choke (if used)
    (2)
    It is essential to connect the shielding to the ground.
    (3)
    Fault relay contacts, for remote signaling of drive status

    The STO safety function integrated into the product can be used to implement an "EMERGENCY STOP" (IEC 60204-1) for category 0 stops.


    Control Connection Diagram in Source Mode


    (1)
    Reference potentiometer SZ1RV1202 (2.2 kΩ) or similar (10 kΩ maximum)


  • Performance Curves

    Derating Curves

    Derating curve for the nominal drive current (In) as a function of temperature and switching frequency.


    X
    Switching frequency

    Above 4 kHz, the drive will reduce the switching frequency automatically in the event of an excessive temperature rise.


  • Technical Description

    Sink / Source Switch Configuration (SW1)

    The logic input switch (SW1) is used to adapt the operation of the logic inputs to the technology of the programmable controller outputs.

    Switch SW1 set to “Source” position


    Switch SW1 set to “Source” position and use of an external power supply for the LIs


    Switch SW1 set to “Sink Int” position


    Switch SW1 set to “Sink Ext” position



Compare products: /