View all
TeSys F

LC1F1154G7
LC1F1154G7
TeSys F contactor - 4P (4 NO) - AC-1 - <= 440 V 200 A - coil 120 V AC
Show more characteristics-
Characteristics
Main range TeSysproduct name TeSys Fproduct or component type Contactordevice short name LC1Fcontactor application Resistive loadutilisation category AC-1poles description 4Ppower pole contact composition 4 NO[Ue] rated operational voltage <= 690 V AC 50/60 Hz[Ie] rated operational current 200 A (at <40 °C) at <= 440 V AC-1[Uc] control circuit voltage 120 V AC 40...400 HzComplementary [Uimp] rated impulse withstand voltage 8 kVovervoltage category III[Ith] conventional free air thermal current 200 A (at 40 °C)rated breaking capacity 920 A conforming to IEC 60947-4-1[Icw] rated short-time withstand current 1100 A 40 °C - 10 s640 A 40 °C - 30 s520 A 40 °C - 1 min400 A 40 °C - 3 min320 A 40 °C - 10 minassociated fuse rating 125 A aM at <= 440 V200 A gG at <= 440 Vaverage impedance 0.37 mOhm - Ith 200 A 50 Hz[Ui] rated insulation voltage 1000 V conforming to IEC 60947-4-11500 V conforming to VDE 0110 group Cpower dissipation per pole 15 W AC-1mounting support Platestandards JIS C8201-4-1IEC 60947-1EN 60947-4-1EN 60947-1IEC 60947-4-1product certifications CBCCCBVRMRoSRINAULDNVLROS (Lloyds register of shipping)ABSconnections - terminals Power circuit: bar 2 cable(s) - busbar cross section: 20 x 3 mmPower circuit: lugs-ring terminals 1 cable(s) 95 mm²Power circuit: connector 1 cable(s) 95 mm²Control circuit: screw clamp terminals 1 cable(s) 1…4 mm²flexible without cable endControl circuit: screw clamp terminals 2 cable(s) 1…4 mm²flexible without cable endControl circuit: screw clamp terminals 1 cable(s) 1…4 mm²flexible with cable endControl circuit: screw clamp terminals 2 cable(s) 1…2.5 mm²flexible with cable endControl circuit: screw clamp terminals 1 cable(s) 1…4 mm²solid without cable endControl circuit: screw clamp terminals 2 cable(s) 1…4 mm²solid without cable endPower circuit: bolted connectiontightening torque Power circuit: 10 N.mControl circuit: 1.2 N.mcontrol circuit voltage limits Operational: 0.85...1.1 Uc 50/60 Hz (at 55 °C)Drop-out: 0.35...0.55 Uc 50/60 Hz (at 55 °C)inrush power in VA 550 VA 50 Hz cos phi 0.3 (at 20 °C)660 VA 60 Hz cos phi 0.3 (at 20 °C)hold-in power consumption in VA 45 VA 50 Hz cos phi 0.3 (at 20 °C)55 VA 60 Hz cos phi 0.3 (at 20 °C)heat dissipation 12…16 Woperating time 35 ms closing (at Uc) 130 ms opening (at Uc)mechanical durability 10 Mcyclesmaximum operating rate 2400 cyc/h 55 °Ccompatibility code LC1FEnvironment IP degree of protection IP2x front face with shrouds conforming to IEC 60529IP2x front face with shrouds conforming to VDE 0106protective treatment THambient air temperature for operation -5…55 °Cambient air temperature for storage -60…80 °Cpermissible ambient air temperature around the device -40…70 °Coperating altitude 3000 m withoutheight 162 mmwidth 200.5 mmdepth 171 mmnet weight 3.83 kgOffer Sustainability Sustainable offer status Green Premium productREACh Regulation EU RoHS Directive Compliant
EU RoHS DeclarationMercury free YesRoHS exemption information China RoHS Regulation China RoHS declaration
Product out of China RoHS scope. Substance declaration for your informationEnvironmental Disclosure Circularity Profile WEEE The product must be disposed on European Union markets following specific waste collection and never end up in rubbish binsContractual warranty Warranty 18 months -
View more
Documents
Language- All Languages18
- English18
- Chinese6
- French8
- German6
- Italian6
- Portuguese6
- Russian6
- Spanish6
CatalogueFormatSizeAdd to My DocumentsTesys catalogue 2019 - 2020 Motor control and protection components (Version 9.2)DescriptionReady-to-use motor starters and all components for builiding specific motor starters ( ircuit breakers, contactors, overload relays , accessories ...).The catalogue can also be downloaded chapter per chapter.Size pdfSize 111.5 MBDate 12/7/19DescriptionReady-to-use motor starters and all components for builiding specific motor starters ( ircuit breakers, contactors, overload relays , accessories ...).The catalogue can also be downloaded chapter per chapter.TeSys catalogue - 2019 - 2020 - chapter B9 high power contactors TeSys F,V, FG, CR1F (Version 7.0)DescriptionContactors for AC-3, AC-1 application, reversing AC-3 pre-cabled, changeover AC-1 precabled : TeSys FVacuum contactors : TeSys VShockproof contactors : TeSys FGMagnetic latching contactors : TeSys CR1FCoils, accessoriesSize pdfSize 8.6 MBDate 15/5/19DescriptionContactors for AC-3, AC-1 application, reversing AC-3 pre-cabled, changeover AC-1 precabled : TeSys FVacuum contactors : TeSys VShockproof contactors : TeSys FGMagnetic latching contactors : TeSys CR1FCoils, accessoriesControl Panel Technical Guide - How to quickly design optimized contactor assemblies (Version 1.1)DescriptionComponents for TeSys D, K, F contactors :_ mechanical & electrical assembling kits for building up advanced motor starters : star-delta, reverser, 2-speed control and also source/load changeover._ parts, as single products : links, interlock, terminals...Many useful tips for optimizing and build up safer assemblies .Size pdfSize 15 MBDate 6/3/18DescriptionComponents for TeSys D, K, F contactors :_ mechanical & electrical assembling kits for building up advanced motor starters : star-delta, reverser, 2-speed control and also source/load changeover._ parts, as single products : links, interlock, terminals...Many useful tips for optimizing and build up safer assemblies .CADFormatSizeAdd to My DocumentsNSX100/160/250 3P; Compact circuit breaker (Version 1.0)DescriptionYou will be redirected to the Traceparts website. Register for free or log in to your Traceparts account to download more than 15 different 2D or 3D CAD formats.Size pdfSize 194.4 KBDate 24/10/18DescriptionYou will be redirected to the Traceparts website. Register for free or log in to your Traceparts account to download more than 15 different 2D or 3D CAD formats.CertificateFormatSizeAdd to My DocumentsSize pdfSize 389.8 KBDate 14/5/13Instruction sheetFormatSizeAdd to My DocumentsSize pdfSize 4.5 MBDate 1/4/19China RoHS declarationFormatSizeAdd to My DocumentsTeSys F contactor - 4P (4 NO) - AC-1 - <= 440 V 200 A - coil 120 V ACDescriptionTeSys F contactor - 4P (4 NO) - AC-1 - <= 440 V 200 A - coil 120 V ACSize pdfSize 195.3 KBDate 7/12/19DescriptionTeSys F contactor - 4P (4 NO) - AC-1 - <= 440 V 200 A - coil 120 V ACDeclaration of conformityFormatSizeAdd to My DocumentsEnd of Life InformationFormatSizeAdd to My DocumentsEU RoHS DeclarationFormatSizeAdd to My DocumentsTeSys F contactor - 4P (4 NO) - AC-1 - <= 440 V 200 A - coil 120 V ACDescriptionTeSys F contactor - 4P (4 NO) - AC-1 - <= 440 V 200 A - coil 120 V ACSize pdfSize 195.3 KBDate 7/12/19DescriptionTeSys F contactor - 4P (4 NO) - AC-1 - <= 440 V 200 A - coil 120 V ACMarine certificateFormatSizeAdd to My DocumentsSize pdfSize 20.1 MBDate 16/10/18Size pdfSize 272.4 KBDate 29/5/17Product Environmental ProfileFormatSizeAdd to My DocumentsTeSys contactor LC1F (Version 2.0)DescriptionPEPSize pdfSize 197.1 KBDate 8/9/15DescriptionPEPREACh DeclarationFormatSizeAdd to My DocumentsTeSys F contactor - 4P (4 NO) - AC-1 - <= 440 V 200 A - coil 120 V ACDescriptionTeSys F contactor - 4P (4 NO) - AC-1 - <= 440 V 200 A - coil 120 V ACSize pdfSize 195.3 KBDate 7/12/19DescriptionTeSys F contactor - 4P (4 NO) - AC-1 - <= 440 V 200 A - coil 120 V AC -
Technical FAQs
No results found.Unfortunately, related FAQs are unavailable due to temporary technical issues. Please try again later.