TeSys D reversing contactor - 3P(3 NO) - AC-3 - <= 440 V 38 A - 240 V AC coil
Show more characteristics-
Characteristics
Main range TeSysproduct name TeSys Dproduct or component type Reversing contactordevice short name LC2Dcontactor application Resistive loadMotor controlutilisation category AC-3AC-1device presentation Preassembled with reversing power busbarpoles description 3Ppower pole contact composition 3 NO[Ue] rated operational voltage Power circuit: <= 690 V AC 25...400 HzPower circuit: <= 300 V DC[Ie] rated operational current 50 A (at <60 °C) at <= 440 V AC AC-1 for power circuit38 A (at <60 °C) at <= 440 V AC AC-3 for power circuitmotor power kW 9 kW at 220...230 V AC 50 Hz18.5 kW at 380...400 V AC 50 Hz18.5 kW at 415...440 V AC 50 Hz18.5 kW at 500 V AC 50 Hz18.5 kW at 660...690 V AC 50 Hzmotor power HP (UL / CSA) 10 hp at 230/240 V AC 60 Hz for 3 phases motors5 hp at 240 V AC 60 Hz for 1 phase motors10 hp at 200/208 V AC 60 Hz for 3 phases motors20 hp at 480 V AC 60 Hz for 3 phases motors25 hp at 600 V AC 60 Hz for 3 phases motorscontrol circuit type AC at 50/60 Hz[Uc] control circuit voltage 240 V AC 50/60 Hzauxiliary contact composition 1 NO + 1 NC[Uimp] rated impulse withstand voltage 6 kV conforming to IEC 60947overvoltage category III[Ith] conventional free air thermal current 10 A (at 60 °C) for signalling circuit50 A (at 60 °C) for power circuitIrms rated making capacity 140 A AC for signalling circuit conforming to IEC 60947-5-1250 A DC for signalling circuit conforming to IEC 60947-5-1550 A at 440 V for power circuit conforming to IEC 60947rated breaking capacity 550 A at 440 V for power circuit conforming to IEC 60947[Icw] rated short-time withstand current 60 A 40 °C - 10 min for power circuit430 A 40 °C - 1 s for power circuit150 A 40 °C - 1 min for power circuit310 A 40 °C - 10 s for power circuit100 A - 1 s for signalling circuit120 A - 500 ms for signalling circuit140 A - 100 ms for signalling circuitassociated fuse rating 10 A gG for signalling circuit conforming to IEC 60947-5-163 A gG at <= 690 V coordination type 1 for power circuit63 A gG at <= 690 V coordination type 2 for power circuitaverage impedance 2 mOhm - Ith 50 A 50 Hz for power circuit[Ui] rated insulation voltage Power circuit: 690 V conforming to IEC 60947-4-1Power circuit: 600 V CSA certifiedPower circuit: 600 V UL certifiedSignalling circuit: 690 V conforming to IEC 60947-1Signalling circuit: 600 V CSA certifiedSignalling circuit: 600 V UL certifiedelectrical durability 1.4 Mcycles 50 A AC-1 at Ue <= 440 V1.4 Mcycles 38 A AC-3 at Ue <= 440 Vpower dissipation per pole 5 W AC-13 W AC-3safety cover Withinterlocking type Mechanicalmounting support PlateRailstandards CSA C22.2 No 14EN 60947-4-1EN 60947-5-1IEC 60947-4-1IEC 60947-5-1UL 508product certifications DNVCCCLROS (Lloyds register of shipping)RINAULGLBVCSAGOSTconnections - terminals Control circuit: lugs-ring terminals (external diameter: 8 mm) Power circuit: lugs-ring terminals (external diameter: 10 mm)tightening torque Control circuit: 1.7 N.m - on lugs-ring terminals - with screwdriver flat Ø 6 mm M3.5Control circuit: 1.7 N.m - on lugs-ring terminals - with screwdriver Philips No 2 M3.5Power circuit: 2.5 N.m - on lugs-ring terminals - with screwdriver flat Ø 8 mm M4Power circuit: 2.5 N.m - on lugs-ring terminals - with screwdriver Philips No 2 M4operating time 12...22 ms closing4...19 ms openingsafety reliability level B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1mechanical durability 15 Mcyclesmaximum operating rate 3600 cyc/h 60 °CComplementary coil technology Without built-in suppressor modulecontrol circuit voltage limits Drop-out: 0.3...0.6 Uc AC 50/60 Hz (at 60 °C)Operational: 0.8...1.1 Uc AC 50 Hz (at 60 °C)Operational: 0.85...1.1 Uc AC 60 Hz (at 60 °C)inrush power in VA 70 VA 60 Hz cos phi 0.75 (at 20 °C)70 VA 50 Hz cos phi 0.75 (at 20 °C)hold-in power consumption in VA 7.5 VA 60 Hz cos phi 0.3 (at 20 °C)7 VA 50 Hz cos phi 0.3 (at 20 °C)heat dissipation 2…3 W at 50/60 Hzauxiliary contacts type type mechanically linked 1 NO + 1 NC conforming to IEC 60947-5-1 type mirror contact 1 NC conforming to IEC 60947-4-1signalling circuit frequency 25...400 Hzminimum switching current 5 mA for signalling circuitminimum switching voltage 17 V for signalling circuitnon-overlap time 1.5 ms on de-energisation between NC and NO contact1.5 ms on energisation between NC and NO contactinsulation resistance > 10 MOhm for signalling circuitEnvironment IP degree of protection IP20 front face conforming to IEC 60529protective treatment TH conforming to IEC 60068-2-30pollution degree 3ambient air temperature for operation -20…60 °Cambient air temperature for storage -60…80 °Cpermissible ambient air temperature around the device -40…70 °C at Ucoperating altitude 3000 m withoutfire resistance 850 °C conforming to IEC 60695-2-1flame retardance V1 conforming to UL 94mechanical robustness Vibrations contactor open: 2 Gn, 5...300 HzVibrations contactor closed: 4 Gn, 5...300 HzShocks contactor closed: 15 Gn for 11 msShocks contactor open: 8 Gn for 11 msheight 85 mmwidth 90 mmdepth 92 mmnet weight 0.807 kgOffer Sustainability REACh Regulation EU RoHS Directive Compliant
EU RoHS DeclarationToxic heavy metal free YesMercury free YesRoHS exemption information China RoHS Regulation Contractual warranty Warranty 18 months -
View more
Documents
Language- English3
EU RoHS DeclarationFormatSizeAdd to My DocumentsTeSys D reversing contactor - 3P(3 NO) - AC-3 - <= 440 V 38 A - 240 V AC coilDescriptionTeSys D reversing contactor - 3P(3 NO) - AC-3 - <= 440 V 38 A - 240 V AC coilSize pdfSize 195.3 KBDate 8/12/19DescriptionTeSys D reversing contactor - 3P(3 NO) - AC-3 - <= 440 V 38 A - 240 V AC coilREACh DeclarationFormatSizeAdd to My DocumentsTeSys D reversing contactor - 3P(3 NO) - AC-3 - <= 440 V 38 A - 240 V AC coilDescriptionTeSys D reversing contactor - 3P(3 NO) - AC-3 - <= 440 V 38 A - 240 V AC coilSize pdfSize 195.3 KBDate 8/12/19DescriptionTeSys D reversing contactor - 3P(3 NO) - AC-3 - <= 440 V 38 A - 240 V AC coilChina RoHS declarationFormatSizeAdd to My DocumentsTeSys D reversing contactor - 3P(3 NO) - AC-3 - <= 440 V 38 A - 240 V AC coilDescriptionTeSys D reversing contactor - 3P(3 NO) - AC-3 - <= 440 V 38 A - 240 V AC coilSize pdfSize 195.3 KBDate 8/12/19DescriptionTeSys D reversing contactor - 3P(3 NO) - AC-3 - <= 440 V 38 A - 240 V AC coil -
Technical FAQs
No results found.Unfortunately, related FAQs are unavailable due to temporary technical issues. Please try again later.