Main range TeSysproduct name TeSys Dproduct or component type Reversing contactordevice short name LC2Dcontactor application Motor controlResistive loadutilisation category AC-3AC-1device presentation Preassembled with reversing power busbarpoles description 3Ppower pole contact composition 3 NO[Ue] rated operational voltage Power circuit: <= 690 V AC 25...400 HzPower circuit: <= 300 V DC[Ie] rated operational current 40 A (at <60 °C) at <= 440 V AC AC-3 for power circuit60 A (at <60 °C) at <= 440 V AC AC-1 for power circuitmotor power kW 18.5 kW at 380...400 V AC 50 Hz11 kW at 220...230 V AC 50 Hz22 kW at 415...440 V AC 50 Hz22 kW at 500 V AC 50 Hz30 kW at 660...690 V AC 50 Hzmotor power HP (UL / CSA) 5 hp at 230/240 V AC 60 Hz for 1 phase motors10 hp at 230/240 V AC 60 Hz for 3 phases motors30 hp at 575/600 V AC 60 Hz for 3 phases motors10 hp at 200/208 V AC 60 Hz for 3 phases motors3 hp at 115 V AC 60 Hz for 1 phase motors30 hp at 460/480 V AC 60 Hz for 3 phases motorscontrol circuit type DC standard[Uc] control circuit voltage 110 V DCauxiliary contact composition 1 NO + 1 NC[Uimp] rated impulse withstand voltage 6 kV conforming to IEC 60947overvoltage category III[Ith] conventional free air thermal current 10 A (at 60 °C) for signalling circuit60 A (at 60 °C) for power circuitIrms rated making capacity 140 A AC for signalling circuit conforming to IEC 60947-5-1250 A DC for signalling circuit conforming to IEC 60947-5-1800 A at 440 V for power circuit conforming to IEC 60947rated breaking capacity 800 A at 440 V for power circuit conforming to IEC 60947[Icw] rated short-time withstand current 72 A 40 °C - 10 min for power circuit165 A 40 °C - 1 min for power circuit320 A 40 °C - 10 s for power circuit720 A 40 °C - 1 s for power circuit100 A - 1 s for signalling circuit120 A - 500 ms for signalling circuit140 A - 100 ms for signalling circuitassociated fuse rating 10 A gG for signalling circuit conforming to IEC 60947-5-180 A gG at <= 690 V coordination type 1 for power circuit80 A gG at <= 690 V coordination type 2 for power circuitaverage impedance 1.5 mOhm - Ith 60 A 50 Hz for power circuit[Ui] rated insulation voltage Power circuit: 690 V conforming to IEC 60947-4-1Power circuit: 600 V CSA certifiedPower circuit: 600 V UL certifiedSignalling circuit: 690 V conforming to IEC 60947-1Signalling circuit: 600 V CSA certifiedSignalling circuit: 600 V UL certifiedelectrical durability 1.5 Mcycles 40 A AC-3 at Ue <= 440 V0.7 Mcycles 60 A AC-1 at Ue <= 440 Vpower dissipation per pole 2.4 W AC-35.4 W AC-1safety cover Withinterlocking type Mechanicalmounting support RailPlatestandards CSA C22.2 No 14EN 60947-4-1EN 60947-5-1IEC 60947-4-1IEC 60947-5-1UL 508product certifications GOSTCSACCCULconnections - terminals Control circuit: screw clamp terminals 1 cable(s) 1…4 mm²flexible without cable endControl circuit: screw clamp terminals 2 cable(s) 1…4 mm²flexible without cable endControl circuit: screw clamp terminals 1 cable(s) 1…4 mm²flexible with cable endControl circuit: screw clamp terminals 2 cable(s) 1…2.5 mm²flexible with cable endControl circuit: screw clamp terminals 1 cable(s) 1…4 mm²solid without cable endControl circuit: screw clamp terminals 2 cable(s) 1…4 mm²solid without cable endPower circuit: EverLink BTR screw connectors 1 cable(s) 1…35 mm²flexible without cable endPower circuit: EverLink BTR screw connectors 2 cable(s) 1…25 mm²flexible without cable endPower circuit: EverLink BTR screw connectors 1 cable(s) 1…35 mm²flexible with cable endPower circuit: EverLink BTR screw connectors 2 cable(s) 1…25 mm²flexible with cable endPower circuit: EverLink BTR screw connectors 1 cable(s) 1…35 mm²solid without cable endPower circuit: EverLink BTR screw connectors 2 cable(s) 1…25 mm²solid without cable endtightening torque Control circuit: 1.7 N.m - on screw clamp terminals - with screwdriver flat Ø 6 mmControl circuit: 1.7 N.m - on screw clamp terminals - with screwdriver Philips No 2Power circuit: 8 N.m - on EverLink BTR screw connectors - cable 25…35 mm² hexagonal screw head 4 mmPower circuit: 5 N.m - on EverLink BTR screw connectors - cable 1…25 mm² hexagonal screw head 4 mmoperating time 16...24 ms opening42.5...57.5 ms closingsafety reliability level B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1mechanical durability 10 Mcyclesmaximum operating rate 3600 cyc/h 60 °CComplementary coil technology Built-in bidirectional peak limiting diode suppressorcontrol circuit voltage limits Drop-out: 0.1...0.3 Uc DC (at 60 °C)Operational: 0.75...1.25 Uc DC (at 60 °C)time constant 34 msinrush power in W 19 W (at 20 °C)hold-in power consumption in W 7.4 W at 20 °Cauxiliary contacts type type mechanically linked 1 NO + 1 NC conforming to IEC 60947-5-1 type mirror contact 1 NC conforming to IEC 60947-4-1signalling circuit frequency 25...400 Hzminimum switching current 5 mA for signalling circuitminimum switching voltage 17 V for signalling circuitnon-overlap time 1.5 ms on de-energisation between NC and NO contact1.5 ms on energisation between NC and NO contactinsulation resistance > 10 MOhm for signalling circuitEnvironment IP degree of protection IP20 front face conforming to IEC 60529protective treatment TH conforming to IEC 60068-2-30pollution degree 3ambient air temperature for operation -5…60 °Cambient air temperature for storage -60…80 °Cpermissible ambient air temperature around the device -40…70 °C at Ucoperating altitude 3000 m withoutfire resistance 850 °C conforming to IEC 60695-2-1flame retardance V1 conforming to UL 94mechanical robustness Vibrations contactor open: 2 Gn, 5...300 HzVibrations contactor closed: 4 Gn, 5...300 HzShocks contactor open: 10 Gn for 11 msShocks contactor closed: 15 Gn for 11 msheight 122 mmwidth 119 mmdepth 120 mmnet weight 2.02 kgOffer Sustainability Sustainable offer status Green Premium productREACh Regulation EU RoHS Directive Compliant
EU RoHS DeclarationToxic heavy metal free YesMercury free YesRoHS exemption information China RoHS Regulation Environmental Disclosure Circularity Profile WEEE The product must be disposed on European Union markets following specific waste collection and never end up in rubbish binsContractual warranty Warranty 18 months -
View more
Documents
Language- All Languages12
- English13
- Chinese4
- French5
- German4
- Italian4
- Portuguese4
- Russian4
- Spanish4
CatalogueFormatSizeAdd to My DocumentsTesys catalogue 2019 - 2020 Motor control and protection components (Version 9.2)DescriptionReady-to-use motor starters and all components for builiding specific motor starters ( ircuit breakers, contactors, overload relays , accessories ...).The catalogue can also be downloaded chapter per chapter.Size pdfSize 111.5 MBDate 12/7/19DescriptionReady-to-use motor starters and all components for builiding specific motor starters ( ircuit breakers, contactors, overload relays , accessories ...).The catalogue can also be downloaded chapter per chapter.TeSys catalogue - 2019 - 2020 - chapter B8 contactors TeSys SK,K, D, SKGC, GC, GY,GF (Version 7.0)DescriptionContactors : TeSys D.Mini contactors, pre cabled reversing contactors : TeSys SK, KModular (on DIN rail) contactors, dual tariif contactors, impulse relays :TeSys SKGC, GC, GY, GFAccessoriesSize pdfSize 12.2 MBDate 15/5/19DescriptionContactors : TeSys D.Mini contactors, pre cabled reversing contactors : TeSys SK, KModular (on DIN rail) contactors, dual tariif contactors, impulse relays :TeSys SKGC, GC, GY, GFAccessoriesControl Panel Technical Guide - How to quickly design optimized contactor assemblies (Version 1.1)DescriptionComponents for TeSys D, K, F contactors :_ mechanical & electrical assembling kits for building up advanced motor starters : star-delta, reverser, 2-speed control and also source/load changeover._ parts, as single products : links, interlock, terminals...Many useful tips for optimizing and build up safer assemblies .Size pdfSize 15 MBDate 6/3/18DescriptionComponents for TeSys D, K, F contactors :_ mechanical & electrical assembling kits for building up advanced motor starters : star-delta, reverser, 2-speed control and also source/load changeover._ parts, as single products : links, interlock, terminals...Many useful tips for optimizing and build up safer assemblies .CADFormatSizeAdd to My Documents3P EVLK REVERS CONT 40A (Version 1.0)Files in documentSize zipSize 1.2 MBDate 18/12/17Files in documentCertificateFormatSizeAdd to My DocumentsInstruction sheetFormatSizeAdd to My DocumentsLC1D..A, LC1D..A3, LC2D..A, LC2D..A3 Everlink 3-pole contactors and reversing contactors 40 to 80 A AC-3 (Version 14)DescriptionLC1D..A, LC1D..A3, LC2D..A, LC2D..A3 Everlink 3-pole contactors and reversing contactors 40 to 80 A AC-3 - Instruction SheetSize pdfSize 7.4 MBDate 1/9/17DescriptionLC1D..A, LC1D..A3, LC2D..A, LC2D..A3 Everlink 3-pole contactors and reversing contactors 40 to 80 A AC-3 - Instruction SheetChina RoHS declarationFormatSizeAdd to My DocumentsTeSys D reversing contactor - 3P(3 NO) - AC-3 - <= 440 V 40 A - 110 V DC coilDescriptionTeSys D reversing contactor - 3P(3 NO) - AC-3 - <= 440 V 40 A - 110 V DC coilSize pdfSize 195.3 KBDate 15/12/19DescriptionTeSys D reversing contactor - 3P(3 NO) - AC-3 - <= 440 V 40 A - 110 V DC coilDeclaration of conformityFormatSizeAdd to My DocumentsEnd of Life InformationFormatSizeAdd to My DocumentsEU RoHS DeclarationFormatSizeAdd to My DocumentsTeSys D reversing contactor - 3P(3 NO) - AC-3 - <= 440 V 40 A - 110 V DC coilDescriptionTeSys D reversing contactor - 3P(3 NO) - AC-3 - <= 440 V 40 A - 110 V DC coilSize pdfSize 195.3 KBDate 15/12/19DescriptionTeSys D reversing contactor - 3P(3 NO) - AC-3 - <= 440 V 40 A - 110 V DC coilProduct Environmental ProfileFormatSizeAdd to My DocumentsREACh DeclarationFormatSizeAdd to My DocumentsTeSys D reversing contactor - 3P(3 NO) - AC-3 - <= 440 V 40 A - 110 V DC coilDescriptionTeSys D reversing contactor - 3P(3 NO) - AC-3 - <= 440 V 40 A - 110 V DC coilSize pdfSize 195.3 KBDate 15/12/19DescriptionTeSys D reversing contactor - 3P(3 NO) - AC-3 - <= 440 V 40 A - 110 V DC coil -
Technical FAQs
No results found.Unfortunately, related FAQs are unavailable due to temporary technical issues. Please try again later.