View all
TeSys D

LC2D65A3LE7
LC2D65A3LE7
TeSys D reversing contactor - 3P(3 NO) - AC-3 - <= 440 V 65 A - 208 V AC coil
Show more characteristics-
Characteristics
Main range TeSysproduct name TeSys Dproduct or component type Reversing contactordevice short name LC2Dcontactor application Resistive loadMotor controlutilisation category AC-1AC-3device presentation Preassembled with reversing power busbarpoles description 3Ppower pole contact composition 3 NO[Ue] rated operational voltage Power circuit: <= 690 V AC 25...400 HzPower circuit: <= 300 V DC[Ie] rated operational current 80 A (at <60 °C) at <= 440 V AC AC-1 for power circuit65 A (at <60 °C) at <= 440 V AC AC-3 for power circuitmotor power kW 18.5 kW at 220...230 V AC 50 Hz30 kW at 380...400 V AC 50 Hz37 kW at 415...440 V AC 50 Hz37 kW at 500 V AC 50 Hz37 kW at 660...690 V AC 50 Hzmotor power HP (UL / CSA) 40 hp at 460/480 V AC 60 Hz for 3 phases motors5 hp at 115 V AC 60 Hz for 1 phase motors10 hp at 230/240 V AC 60 Hz for 1 phase motors20 hp at 200/208 V AC 60 Hz for 3 phases motors20 hp at 230/240 V AC 60 Hz for 3 phases motors50 hp at 575/600 V AC 60 Hz for 3 phases motorscontrol circuit type AC at 50/60 Hz[Uc] control circuit voltage 208 V AC 50/60 Hzauxiliary contact composition 1 NO + 1 NC[Uimp] rated impulse withstand voltage 6 kV conforming to IEC 60947overvoltage category III[Ith] conventional free air thermal current 10 A (at 60 °C) for signalling circuit80 A (at 60 °C) for power circuitIrms rated making capacity 140 A AC for signalling circuit conforming to IEC 60947-5-1250 A DC for signalling circuit conforming to IEC 60947-5-11000 A at 440 V for power circuit conforming to IEC 60947rated breaking capacity 1000 A at 440 V for power circuit conforming to IEC 60947[Icw] rated short-time withstand current 520 A 40 °C - 10 s for power circuit900 A 40 °C - 1 s for power circuit110 A 40 °C - 10 min for power circuit260 A 40 °C - 1 min for power circuit100 A - 1 s for signalling circuit120 A - 500 ms for signalling circuit140 A - 100 ms for signalling circuitassociated fuse rating 10 A gG for signalling circuit conforming to IEC 60947-5-1125 A gG at <= 690 V coordination type 1 for power circuit125 A gG at <= 690 V coordination type 2 for power circuitaverage impedance 1.5 mOhm - Ith 80 A 50 Hz for power circuit[Ui] rated insulation voltage Power circuit: 690 V conforming to IEC 60947-4-1Power circuit: 600 V CSA certifiedPower circuit: 600 V UL certifiedSignalling circuit: 690 V conforming to IEC 60947-1Signalling circuit: 600 V CSA certifiedSignalling circuit: 600 V UL certifiedelectrical durability 1.45 Mcycles 65 A AC-3 at Ue <= 440 V1.4 Mcycles 80 A AC-1 at Ue <= 440 Vpower dissipation per pole 9.6 W AC-16.3 W AC-3safety cover Withinterlocking type Mechanicalmounting support PlateRailstandards CSA C22.2 No 14EN 60947-4-1EN 60947-5-1IEC 60947-4-1IEC 60947-5-1UL 508product certifications ULCCCCSAGOSTconnections - terminals Control circuit: spring terminals 1 cable(s) 2.5 mm²flexible without cable endControl circuit: spring terminals 2 cable(s) 2.5 mm²flexible without cable endPower circuit: EverLink BTR screw connectors 1 cable(s) 1…35 mm²flexible without cable endPower circuit: EverLink BTR screw connectors 2 cable(s) 1…25 mm²flexible without cable endPower circuit: EverLink BTR screw connectors 1 cable(s) 1…35 mm²flexible with cable endPower circuit: EverLink BTR screw connectors 2 cable(s) 1…25 mm²flexible with cable endPower circuit: EverLink BTR screw connectors 1 cable(s) 1…35 mm²solid without cable endPower circuit: EverLink BTR screw connectors 2 cable(s) 1…25 mm²solid without cable endtightening torque Power circuit: 8 N.m - on screw clamp terminals - cable 25…35 mm² hexagonal screw head 4 mmPower circuit: 5 N.m - on screw clamp terminals - cable 2.5…25 mm² hexagonal screw head 4 mmoperating time 4...19 ms opening12...26 ms closingsafety reliability level B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1mechanical durability 6 Mcyclesmaximum operating rate 3600 cyc/h 60 °CComplementary coil technology Without built-in suppressor modulecontrol circuit voltage limits Drop-out: 0.3...0.6 Uc AC 50/60 Hz (at 60 °C)Operational: 0.8...1.1 Uc AC 50 Hz (at 60 °C)Operational: 0.85...1.1 Uc AC 60 Hz (at 60 °C)inrush power in VA 140 VA 60 Hz cos phi 0.75 (at 20 °C)160 VA 50 Hz cos phi 0.75 (at 20 °C)hold-in power consumption in VA 13 VA 60 Hz cos phi 0.3 (at 20 °C)15 VA 50 Hz cos phi 0.3 (at 20 °C)heat dissipation 4…5 W at 50/60 Hzauxiliary contacts type type mechanically linked 1 NO + 1 NC conforming to IEC 60947-5-1 type mirror contact 1 NC conforming to IEC 60947-4-1signalling circuit frequency 25...400 Hzminimum switching current 5 mA for signalling circuitminimum switching voltage 17 V for signalling circuitnon-overlap time 1.5 ms on de-energisation between NC and NO contact1.5 ms on energisation between NC and NO contactinsulation resistance > 10 MOhm for signalling circuitEnvironment IP degree of protection IP20 front face conforming to IEC 60529protective treatment TH conforming to IEC 60068-2-30pollution degree 3ambient air temperature for operation -5…60 °Cambient air temperature for storage -60…80 °Cpermissible ambient air temperature around the device -40…70 °C at Ucoperating altitude 3000 m withoutfire resistance 850 °C conforming to IEC 60695-2-1flame retardance V1 conforming to UL 94mechanical robustness Vibrations contactor open: 2 Gn, 5...300 HzVibrations contactor closed: 4 Gn, 5...300 HzShocks contactor open: 10 Gn for 11 msShocks contactor closed: 15 Gn for 11 msheight 122 mmwidth 119 mmdepth 120 mmnet weight 1.89 kgContractual warranty Warranty 18 months -
View more
Documents
Language- All Languages2
- English3
- Chinese3
- French3
- German3
- Italian3
- Portuguese3
- Russian3
- Spanish3
CADFormatSizeAdd to My Documents3P EVLK REVERS CONT 40A (Version 1.0)Files in documentSize zipSize 1.2 MBDate 18/12/17Files in documentInstruction sheetFormatSizeAdd to My DocumentsLC1D..A, LC1D..A3, LC2D..A, LC2D..A3 Everlink 3-pole contactors and reversing contactors 40 to 80 A AC-3 (Version 14)DescriptionLC1D..A, LC1D..A3, LC2D..A, LC2D..A3 Everlink 3-pole contactors and reversing contactors 40 to 80 A AC-3 - Instruction SheetSize pdfSize 7.4 MBDate 1/9/17DescriptionLC1D..A, LC1D..A3, LC2D..A, LC2D..A3 Everlink 3-pole contactors and reversing contactors 40 to 80 A AC-3 - Instruction Sheet -
Technical FAQs
No results found.Unfortunately, related FAQs are unavailable due to temporary technical issues. Please try again later.