TeSys D changeover contactor - 4P(4 NO) - AC-1 - <= 440 V 25 A - 42 V AC coil
Show more characteristics-
Characteristics
Main range TeSysproduct name TeSys Dproduct or component type Changeover contactordevice short name LC2Dcontactor application Resistive loadutilisation category AC-1device presentation Preassembled, with prewired power connectionspoles description 4Ppower pole contact composition 4 NO[Ue] rated operational voltage Power circuit: <= 690 V AC 25...400 HzPower circuit: <= 300 V DC[Ie] rated operational current 25 A (at <60 °C) at <= 440 V AC AC-1 for power circuitcontrol circuit type AC at 50/60 Hz[Uc] control circuit voltage 42 V AC 50/60 Hzauxiliary contact composition 1 NO + 1 NC[Uimp] rated impulse withstand voltage 6 kV conforming to IEC 60947overvoltage category III[Ith] conventional free air thermal current 10 A (at 60 °C) for signalling circuit25 A (at 60 °C) for power circuitIrms rated making capacity 250 A at 440 V for power circuit conforming to IEC 60947140 A AC for signalling circuit conforming to IEC 60947-5-1250 A DC for signalling circuit conforming to IEC 60947-5-1rated breaking capacity 250 A at 440 V for power circuit conforming to IEC 60947[Icw] rated short-time withstand current 30 A 40 °C - 10 min for power circuit61 A 40 °C - 1 min for power circuit105 A 40 °C - 10 s for power circuit210 A 40 °C - 1 s for power circuit100 A - 1 s for signalling circuit120 A - 500 ms for signalling circuit140 A - 100 ms for signalling circuitassociated fuse rating 10 A gG for signalling circuit conforming to IEC 60947-5-140 A gG at <= 690 V coordination type 1 for power circuit25 A gG at <= 690 V coordination type 2 for power circuitaverage impedance 2.5 mOhm - Ith 25 A 50 Hz for power circuit[Ui] rated insulation voltage Power circuit: 690 V conforming to IEC 60947-4-1Power circuit: 600 V CSA certifiedPower circuit: 600 V UL certifiedSignalling circuit: 690 V conforming to IEC 60947-1Signalling circuit: 600 V CSA certifiedSignalling circuit: 600 V UL certifiedelectrical durability 0.8 Mcycles 25 A AC-1 at Ue <= 440 Vpower dissipation per pole 1.56 W AC-1safety cover Withinterlocking type Mechanicalmounting support RailPlatestandards CSA C22.2 No 14EN 60947-4-1EN 60947-5-1IEC 60947-4-1IEC 60947-5-1UL 508product certifications CCCGLBVLROS (Lloyds register of shipping)RINACSAGOSTDNVULconnections - terminals Power circuit: screw clamp terminals 1 cable(s) 1…4 mm²flexible without cable endPower circuit: screw clamp terminals 2 cable(s) 1…4 mm²flexible without cable endPower circuit: screw clamp terminals 1 cable(s) 1…4 mm²flexible with cable endPower circuit: screw clamp terminals 2 cable(s) 1…2.5 mm²flexible with cable endPower circuit: screw clamp terminals 1 cable(s) 1…4 mm²solid without cable endPower circuit: screw clamp terminals 2 cable(s) 1…4 mm²solid without cable endControl circuit: screw clamp terminals 1 cable(s) 1…4 mm²flexible without cable endControl circuit: screw clamp terminals 2 cable(s) 1…4 mm²flexible without cable endControl circuit: screw clamp terminals 1 cable(s) 1…4 mm²flexible with cable endControl circuit: screw clamp terminals 2 cable(s) 1…2.5 mm²flexible with cable endControl circuit: screw clamp terminals 1 cable(s) 1…4 mm²solid without cable endControl circuit: screw clamp terminals 2 cable(s) 1…4 mm²solid without cable endtightening torque Power circuit: 1.7 N.m - on screw clamp terminals - with screwdriver flat Ø 6 mmPower circuit: 1.7 N.m - on screw clamp terminals - with screwdriver Philips No 2Control circuit: 1.7 N.m - on screw clamp terminals - with screwdriver flat Ø 6 mmControl circuit: 1.7 N.m - on screw clamp terminals - with screwdriver Philips No 2operating time 12...22 ms closing4...19 ms openingsafety reliability level B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1mechanical durability 15 Mcyclesmaximum operating rate 3600 cyc/h 60 °CComplementary coil technology Without built-in suppressor modulecontrol circuit voltage limits Drop-out: 0.3...0.6 Uc AC 50/60 Hz (at 60 °C)Operational: 0.8...1.1 Uc AC 50 Hz (at 60 °C)Operational: 0.85...1.1 Uc AC 60 Hz (at 60 °C)inrush power in VA 70 VA 60 Hz cos phi 0.75 (at 20 °C)70 VA 50 Hz cos phi 0.75 (at 20 °C)hold-in power consumption in VA 7.5 VA 60 Hz cos phi 0.3 (at 20 °C)7 VA 50 Hz cos phi 0.3 (at 20 °C)heat dissipation 2…3 W at 50/60 Hzauxiliary contacts type type mechanically linked 1 NO + 1 NC conforming to IEC 60947-5-1 type mirror contact 1 NC conforming to IEC 60947-4-1signalling circuit frequency 25...400 Hzminimum switching current 5 mA for signalling circuitminimum switching voltage 17 V for signalling circuitnon-overlap time 1.5 ms on de-energisation between NC and NO contact1.5 ms on energisation between NC and NO contactinsulation resistance > 10 MOhm for signalling circuitEnvironment IP degree of protection IP20 front face conforming to IEC 60529protective treatment TH conforming to IEC 60068-2-30pollution degree 3ambient air temperature for operation -5…60 °Cambient air temperature for storage -60…80 °Cpermissible ambient air temperature around the device -40…70 °C at Ucoperating altitude 3000 m withoutfire resistance 850 °C conforming to IEC 60695-2-1flame retardance V1 conforming to UL 94mechanical robustness Vibrations contactor open: 2 Gn, 5...300 HzVibrations contactor closed: 4 Gn, 5...300 HzShocks contactor open: 10 Gn for 11 msShocks contactor closed: 15 Gn for 11 msheight 85 mmwidth 90 mmdepth 90 mmnet weight 0.73 kgOffer Sustainability Sustainable offer status Green Premium productREACh Regulation REACh free of SVHC YesEU RoHS Directive Compliant
EU RoHS DeclarationToxic heavy metal free YesMercury free YesRoHS exemption information China RoHS Regulation Environmental Disclosure Circularity Profile WEEE The product must be disposed on European Union markets following specific waste collection and never end up in rubbish binsContractual warranty Warranty 18 months -
View more
Documents
Language- All Languages13
- English14
- Chinese3
- French3
CatalogueFormatSizeAdd to My DocumentsTesys catalogue 2019 - 2020 Motor control and protection components (Version 9.2)DescriptionReady-to-use motor starters and all components for builiding specific motor starters ( ircuit breakers, contactors, overload relays , accessories ...).The catalogue can also be downloaded chapter per chapter.Size pdfSize 111.5 MBDate 12/7/19DescriptionReady-to-use motor starters and all components for builiding specific motor starters ( ircuit breakers, contactors, overload relays , accessories ...).The catalogue can also be downloaded chapter per chapter.TeSys catalogue - 2019 - 2020 - chapter B8 contactors TeSys SK,K, D, SKGC, GC, GY,GF (Version 7.0)DescriptionContactors : TeSys D.Mini contactors, pre cabled reversing contactors : TeSys SK, KModular (on DIN rail) contactors, dual tariif contactors, impulse relays :TeSys SKGC, GC, GY, GFAccessoriesSize pdfSize 12.2 MBDate 15/5/19DescriptionContactors : TeSys D.Mini contactors, pre cabled reversing contactors : TeSys SK, KModular (on DIN rail) contactors, dual tariif contactors, impulse relays :TeSys SKGC, GC, GY, GFAccessoriesControl Panel Technical Guide - How to quickly design optimized contactor assemblies (Version 1.1)DescriptionComponents for TeSys D, K, F contactors :_ mechanical & electrical assembling kits for building up advanced motor starters : star-delta, reverser, 2-speed control and also source/load changeover._ parts, as single products : links, interlock, terminals...Many useful tips for optimizing and build up safer assemblies .Size pdfSize 15 MBDate 6/3/18DescriptionComponents for TeSys D, K, F contactors :_ mechanical & electrical assembling kits for building up advanced motor starters : star-delta, reverser, 2-speed control and also source/load changeover._ parts, as single products : links, interlock, terminals...Many useful tips for optimizing and build up safer assemblies .CADFormatSizeAdd to My DocumentsREVERSING CONTACTOR LC2DT 20-25 A AC coil (Version 1.0)Files in documentSize zipSize 16.6 MBDate 18/12/17Files in documentCertificateFormatSizeAdd to My DocumentsInstruction sheetFormatSizeAdd to My DocumentsLC2 DT... 4-pole 20 to 40 A AC-1 changeover contactors pairs with screw clamp terminals (Version 04)Size pdfSize 946.6 KBDate 1/6/16Declaration of conformityFormatSizeAdd to My DocumentsSize pdfSize 303.8 KBDate 28/6/19End of Life InformationFormatSizeAdd to My DocumentsTeSys D Contactors AC 09 to 18A (Version 2.0)DescriptionTeSys D Contactors AC 09 to 18ASize pdfSize 157.9 KBDate 28/4/16DescriptionTeSys D Contactors AC 09 to 18AEU RoHS DeclarationFormatSizeAdd to My DocumentsTeSys D changeover contactor - 4P(4 NO) - AC-1 - <= 440 V 25 A - 42 V AC coilDescriptionTeSys D changeover contactor - 4P(4 NO) - AC-1 - <= 440 V 25 A - 42 V AC coilSize pdfSize 195.3 KBDate 6/12/19DescriptionTeSys D changeover contactor - 4P(4 NO) - AC-1 - <= 440 V 25 A - 42 V AC coilProduct Environmental ProfileFormatSizeAdd to My Documents3P CONT 9A AC3 4KW 1NO 1NC 230VAC COIL (Version 3.0)Description3P CONT 9A AC3 4KW 1NO 1NC 230VAC COILSize pdfSize 132 KBDate 28/4/16Description3P CONT 9A AC3 4KW 1NO 1NC 230VAC COILREACh DeclarationFormatSizeAdd to My DocumentsTeSys D changeover contactor - 4P(4 NO) - AC-1 - <= 440 V 25 A - 42 V AC coilDescriptionTeSys D changeover contactor - 4P(4 NO) - AC-1 - <= 440 V 25 A - 42 V AC coilSize pdfSize 195.3 KBDate 6/12/19DescriptionTeSys D changeover contactor - 4P(4 NO) - AC-1 - <= 440 V 25 A - 42 V AC coilChina RoHS declarationFormatSizeAdd to My DocumentsTeSys D changeover contactor - 4P(4 NO) - AC-1 - <= 440 V 25 A - 42 V AC coilDescriptionTeSys D changeover contactor - 4P(4 NO) - AC-1 - <= 440 V 25 A - 42 V AC coilSize pdfSize 195.3 KBDate 6/12/19DescriptionTeSys D changeover contactor - 4P(4 NO) - AC-1 - <= 440 V 25 A - 42 V AC coil -
Technical FAQs