View all
TeSys K

LP1K06015SD
LP1K06015SD
TeSys K contactor - 3P - AC-3 <= 440 V 6 A - 1 NC aux. - 72 V DC coil
Show more characteristics-
Characteristics
Main range TeSysproduct or component type Contactorproduct name TeSys Kdevice short name LP1Kdevice application Controlcontactor application Motor controlComplementary utilisation category AC-4AC-3poles description 3Ppower pole contact composition 3 NO[Ue] rated operational voltage Power circuit: 690 V AC 50/60 HzSignalling circuit: <= 690 V AC 50/60 Hz[Ie] rated operational current 6 A at <= 440 V AC AC-3 for power circuitauxiliary contact composition 1 NC[Uimp] rated impulse withstand voltage 8 kVovervoltage category III[Ith] conventional free air thermal current 20 A (at 50 °C) for power circuit10 A (at 50 °C) for signalling circuitIrms rated making capacity 110 A AC for power circuit conforming to NF C 63-110110 A AC for power circuit conforming to IEC 60947110 A AC for signalling circuit conforming to IEC 60947rated breaking capacity 110 A at 415 V conforming to IEC 60947110 A at 440 V conforming to IEC 6094780 A at 500 V conforming to IEC 60947110 A at 220...230 V conforming to IEC 60947110 A at 380...400 V conforming to IEC 6094770 A at 660...690 V conforming to IEC 60947associated fuse rating 25 A gG at <= 440 V for power circuit25 A aM for power circuit10 A gG for signalling circuit conforming to IEC 6094710 A gG for signalling circuit conforming to VDE 0660average impedance 3 mOhm - Ith 20 A 50 Hz for power circuit[Ui] rated insulation voltage Power circuit: 600 V conforming to UL 508Power circuit: 690 V conforming to IEC 60947-4-1Signalling circuit: 690 V conforming to IEC 60947-4-1Signalling circuit: 690 V conforming to IEC 60947-5-1Signalling circuit: 600 V conforming to UL 508Power circuit: 600 V conforming to CSA C22.2 No 14Signalling circuit: 600 V conforming to CSA C22.2 No 14insulation resistance > 10 MOhm for signalling circuitinrush power in W 3 W (at 20 °C)hold-in power consumption in W 3 W at 20 °Ccontrol circuit voltage limits Operational: 0.8...1.15 Uc (at <50 °C)Drop-out: 0.1...0.75 Uc (at <50 °C)maximum operating rate 3600 cyc/hauxiliary contacts type type instantaneous 1 NCminimum switching current 5 mA for signalling circuitminimum switching voltage 17 V for signalling circuitmounting support Printed circuit boardsoperating time 30...40 ms coil energisation and NO closing10 ms coil de-energisation and NO openingsafety reliability level B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1mechanical durability 10 Mcyclesheight 58 mmwidth 45 mmdepth 57 mmnet weight 0.225 kgEnvironment product certifications ULCSAambient air temperature for storage -50…80 °Coperating altitude 2000 m withoutflame retardance V1 conforming to UL 94Requirement 2 conforming to NF F 16-101Requirement 2 conforming to NF F 16-102Contractual warranty Warranty 18 months -
View more
Documents
Language- English1
Product Environmental ProfileFormatSizeAdd to My Documents -
Technical FAQs
No results found.Unfortunately, related FAQs are unavailable due to temporary technical issues. Please try again later.