Main range of product TeSys Krange TeSysproduct or component type Contactordevice short name LP1Kcontactor application Motor controlutilisation category AC-3AC-4poles description 3Ppole contact composition 3 NO[Ie] rated operational current 6 A at <= 440 V AC AC-3 for power circuitauxiliary contact composition 1 NO[Uc] control circuit voltage 12 V DCComplementary auxiliary contacts type type instantaneous 1 NOcontrol circuit voltage limits Operational: 0.8...1.15 Uc (at <50 °C)Drop-out: 0.1...0.75 Uc (at <50 °C)[Ui] rated insulation voltage Power circuit: 600 V conforming to UL 508Power circuit: 690 V conforming to IEC 60947-4-1Signalling circuit: 690 V conforming to IEC 60947-4-1Signalling circuit: 690 V conforming to IEC 60947-5-1Signalling circuit: 600 V conforming to UL 508Power circuit: 600 V conforming to CSA C22.2 No 14Signalling circuit: 600 V conforming to CSA C22.2 No 14[Uimp] rated impulse withstand voltage 8 kVovervoltage category IIImounting support PlateRailflame retardance V1 conforming to UL 94Requirement 2 conforming to NF F 16-101Requirement 2 conforming to NF F 16-102tightening torque 1.3 N.m - on screw clamp terminals - with screwdriver Philips No 21.3 N.m - on screw clamp terminals - with screwdriver flat Ø 6 mm[Ue] rated operational voltage Power circuit: 690 V AC 50/60 HzSignalling circuit: <= 690 V AC 50/60 Hz[Ith] conventional free air thermal current 20 A (at 50 °C) for power circuit10 A (at 50 °C) for signalling circuitIrms rated making capacity 110 A AC for power circuit conforming to NF C 63-110110 A AC for power circuit conforming to IEC 60947110 A AC for signalling circuit conforming to IEC 60947rated breaking capacity 110 A at 415 V conforming to IEC 60947110 A at 440 V conforming to IEC 6094780 A at 500 V conforming to IEC 60947110 A at 220...230 V conforming to IEC 60947110 A at 380...400 V conforming to IEC 6094770 A at 660...690 V conforming to IEC 60947associated fuse rating 25 A gG at <= 440 V for power circuit25 A aM for power circuit10 A gG for signalling circuit conforming to IEC 6094710 A gG for signalling circuit conforming to VDE 0660average impedance 3 mOhm - Ith 20 A 50 Hz for power circuitinrush power in W 3 W (at 20 °C)hold-in power consumption in W 3 W at 20 °Coperating time 30...40 ms coil energisation and NO closing10 ms coil de-energisation and NO openingsafety reliability level B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1mechanical durability 10 Mcyclesmaximum operating rate 3600 cyc/hminimum switching current 5 mA for signalling circuitminimum switching voltage 17 V for signalling circuitinsulation resistance > 10 MOhm for signalling circuitheight 58 mmwidth 45 mmdepth 57 mmnet weight 0.225 kgEnvironment product certifications ULCSAambient air temperature for operation -25…50 °Cambient air temperature for storage -50…80 °Coperating altitude 2000 m withoutOffer Sustainability Sustainable offer status Green Premium productREACh Regulation EU RoHS Directive Compliant
EU RoHS DeclarationMercury free YesRoHS exemption information China RoHS Regulation China RoHS declaration
Product out of China RoHS scope. Substance declaration for your informationEnvironmental Disclosure Circularity Profile WEEE The product must be disposed on European Union markets following specific waste collection and never end up in rubbish binsContractual warranty Warranty 18 months -
View more
Documents
Language- All Languages15
- English16
- French6
CatalogueFormatSizeAdd to My DocumentsTesys catalogue 2019 - 2020 Motor control and protection components (Version 9.2)DescriptionReady-to-use motor starters and all components for builiding specific motor starters ( ircuit breakers, contactors, overload relays , accessories ...).The catalogue can also be downloaded chapter per chapter.Size pdfSize 111.5 MBDate 12/7/19DescriptionReady-to-use motor starters and all components for builiding specific motor starters ( ircuit breakers, contactors, overload relays , accessories ...).The catalogue can also be downloaded chapter per chapter.TeSys catalogue - 2019 - 2020 - chapter B8 contactors TeSys SK,K, D, SKGC, GC, GY,GF (Version 7.0)DescriptionContactors : TeSys D.Mini contactors, pre cabled reversing contactors : TeSys SK, KModular (on DIN rail) contactors, dual tariif contactors, impulse relays :TeSys SKGC, GC, GY, GFAccessoriesSize pdfSize 12.2 MBDate 15/5/19DescriptionContactors : TeSys D.Mini contactors, pre cabled reversing contactors : TeSys SK, KModular (on DIN rail) contactors, dual tariif contactors, impulse relays :TeSys SKGC, GC, GY, GFAccessoriesControl Panel Technical Guide - How to quickly design optimized contactor assemblies (Version 1.1)DescriptionComponents for TeSys D, K, F contactors :_ mechanical & electrical assembling kits for building up advanced motor starters : star-delta, reverser, 2-speed control and also source/load changeover._ parts, as single products : links, interlock, terminals...Many useful tips for optimizing and build up safer assemblies .Size pdfSize 15 MBDate 6/3/18DescriptionComponents for TeSys D, K, F contactors :_ mechanical & electrical assembling kits for building up advanced motor starters : star-delta, reverser, 2-speed control and also source/load changeover._ parts, as single products : links, interlock, terminals...Many useful tips for optimizing and build up safer assemblies .CADFormatSizeAdd to My DocumentsCAD for LP1K0610JD: TeSys K contactor - 3P - AC-3 <= 440 V 6 A - 1 NO aux. - 12 V DC coil (Version 1.0)DescriptionYou will be redirected to the ThomasNet website. Then you could download this CAD model in more than 15 different 2D or 3D CAD formats.CAD for LP1K0610JD: TeSys K contactor - 3P - AC-3 <= 440 V 6 A - 1 NO aux. - 12 V DC coil (Version 1.0)DescriptionYou will be redirected to the ThomasNet website. Then you could download this CAD model in more than 15 different 2D or 3D CAD formats.CertificateFormatSizeAdd to My DocumentsInstruction sheetFormatSizeAdd to My DocumentsLC1-K contactor (Version 07)Description1378085 W913780850511A07 W913780850511 W91378085 1378085_01A55 w913780850511Size pdfSize 623.9 KBDate 1/6/16Description1378085 W913780850511A07 W913780850511 W91378085 1378085_01A55 w913780850511China RoHS declarationFormatSizeAdd to My DocumentsLP1K0610JD : TeSys K contactor - 3P - AC-3 <= 440 V 6 A - 1 NO aux. - 12 V DC coilDescriptionTeSys K contactor - 3P - AC-3 <= 440 V 6 A - 1 NO aux. - 12 V DC coilSize pdfSize 195.3 KBDate 15/12/19DescriptionTeSys K contactor - 3P - AC-3 <= 440 V 6 A - 1 NO aux. - 12 V DC coilDeclaration of conformityFormatSizeAdd to My DocumentsEnd of Life InformationFormatSizeAdd to My DocumentsEU RoHS DeclarationFormatSizeAdd to My DocumentsLP1K0610JD : TeSys K contactor - 3P - AC-3 <= 440 V 6 A - 1 NO aux. - 12 V DC coilDescriptionTeSys K contactor - 3P - AC-3 <= 440 V 6 A - 1 NO aux. - 12 V DC coilSize pdfSize 195.3 KBDate 15/12/19DescriptionTeSys K contactor - 3P - AC-3 <= 440 V 6 A - 1 NO aux. - 12 V DC coilProduct Environmental ProfileFormatSizeAdd to My DocumentsREACh DeclarationFormatSizeAdd to My DocumentsLP1K0610JD : TeSys K contactor - 3P - AC-3 <= 440 V 6 A - 1 NO aux. - 12 V DC coilDescriptionTeSys K contactor - 3P - AC-3 <= 440 V 6 A - 1 NO aux. - 12 V DC coilSize pdfSize 195.3 KBDate 15/12/19DescriptionTeSys K contactor - 3P - AC-3 <= 440 V 6 A - 1 NO aux. - 12 V DC coil -
Technical FAQs
No results found.Unfortunately, related FAQs are unavailable due to temporary technical issues. Please try again later.