Latvia

Laipni aicināti Schneider Electric tīmekļa vietnē

Laipni lūdzam mūsu tīmekļa vietnē!

Varat izvēlēties citu valsti, lai skatītu pieejamo produkciju, vai apmeklēt mūsu globālo tīmekļa vietni, lai skatītu informāciju par uzņēmumu.

Izvēlieties citu valsti vai reģionu

Rack PDU 2G, Metered, ZeroU, 20A/208V, 16A/230V, (18) C13 & (2) C19

Rādīt vairāk raksturlielumus >
Pievienot sadaļai Mani produkti Noņemt no sadaļas Mani produkti

  • Overview
    Description
    APC Metered Rack Power Distribution Units (PDUs) provide active metering to enable energy optimization and circuit protection. User-defined alarm thresholds mitigate risk with real-time local and remote alerts to warn of potential circuit overloads. Metered Rack PDUs provide power utilization data to allow Data Center Managers to make informed decisions on load balancing and right sizing IT environments to lower total cost of ownership. Metered Rack PDUs include real power monitoring, a temperature/humidity sensor port, locking IEC receptacles, and ultra low profile circuit breakers. Users can access and configure Metered Rack PDUs through secure Web, SNMP, or Telnet Interfaces which are complimented by APC Centralized Management platforms using InfraStruxure Central, Operations, Capacity, and Energy Efficiency.
    Model Name
    Rack PDU 2G, Metered, ZeroU, 20A/208V, 16A/230V, (18) C13 & (2) C19
    Includes
    Installation guide , Rack Mounting brackets , Safety guide , Serial configuration cable
    Standard Lead Time
    Usually in Stock
    Product Distribution
    Afghanistan , Albania , Algeria , Andorra , Angola , Anguilla , Antigua And Barbuda , Argentina , Armenia , Aruba , Australia , Austria , Azerbaijan , Bahamas , Bahrain , Bangladesh , Barbados , Belarus , Belgium , Belize , Benin , Bermuda , Bhutan , Bolivia , Bosnia And Herzegovina , Botswana , Brazil , Brunei Darussalam , Bulgaria , Burkina Faso , Burundi , Cameroon , Canada , Cayman Islands , Central African Republic , Chad , Chile , China , Colombia , Congo , CONGO, THE DEMOCRATIC REPUBLIC OF THE , Cook Islands , Costa Rica , Cote D'Ivoire , Croatia , Cuba , Cyprus , Czech Republic , Denmark , Djibouti , Dominica , Dominican Republic , East Timor , Ecuador , Egypt , El Salvador , Equatorial Guinea , Eritrea , Estonia , Ethiopia , Falkland Islands (Malvinas) , Fiji , Finland , France , Gabon , Gambia , Georgia , Germany , Ghana , Gibraltar , Greece , Grenada , Guadeloupe , Guatemala , Guinea , Guyana , French Guiana , Haiti , Honduras , Hong Kong , Hungary , Iceland , India , Indonesia , Iran (Islamic Republic Of) , Iraq , Ireland , Israel , Italy , Jamaica , Japan , Jordan , Kazakhstan , Kenya , KOREA, REPUBLIC OF , Kuwait , Latvia , Lebanon , Lesotho , Liberia , Liechtenstein , Lithuania , Luxembourg , Macedonia , Madagascar , Malawi , Malaysia , Mali , Malta , Martinique , Mauritania , Mauritius , Mayotte , Mexico , Moldova, Republic Of , Mongolia , Morocco , Mozambique , Myanmar , Namibia , Nepal , Netherlands , Netherlands Antilles , New Zealand , Nicaragua , Niger , Nigeria , Norway , Oman , Pakistan , Panama , Papua New Guinea , Paraguay , Peru , Philippines , Poland , Portugal , Puerto Rico , Reunion , Romania , Russian Federation , Rwanda , SAINT KITTS AND NEVIS , SAINT LUCIA , SAINT VINCENT AND THE GRENADINES , Saudi Arabia , Senegal , Sierra Leone , Singapore , Slovakia (Slovak Republic) , Slovenia , Somalia , South Africa , Spain , Sri Lanka , Sudan , Suriname , Sweden , Switzerland , Taiwan , Tajikistan , TANZANIA, UNITED REPUBLIC OF , Thailand , Togo , Trinidad And Tobago , Tunisia , Turkey , Turkmenistan , Turks And Caicos Islands , Uganda , Ukraine , United Arab Emirates , United States , Uruguay , Uzbekistan , Venezuela , Viet Nam , VIRGIN ISLANDS (UNITED STATES) , Western Sahara , Yemen , Zambia , Zimbabwe
    Output
    Nominal Output Voltage
    100V , 200V , 208V , 230V
    Maximum Total Current Draw per Phase
    16 A
    Output Connections
    (18) IEC 320 C13 (Battery Backup) , (2) IEC 320 C19 (Battery Backup)
    Overload Protection
    No
    Input
    Nominal Input Voltage
    200V , 208V , 230V
    Input Frequency
    50/60 Hz
    Regulatory Derated Input Current (North America)
    16 A
    Input Connections
    IEC-320 C20
    Acceptable Input Voltage
    100-240 VAC
    Maximum Input Current per phase
    20 A
    Physical
    Net Weight
    2.93 kg
    Maximum Height
    902.0 mm
    Maximum Width
    56.0 mm
    Maximum Depth
    44.0 mm
    Shipping Weight
    4.2 kg
    Shipping Height
    1124.0 mm
    Shipping Width
    162.0 mm
    Shipping Depth
    107.0 mm
    Color
    Black
    Environmental
    Operating Environment
    -5 - 45 °C
    Operating Relative Humidity
    5 - 95 %
    Operating Elevation
    0-3000 meters
    Storage Temperature
    -25 - 65 °C
    Storage Relative Humidity
    5 - 95 %
    Storage Elevation
    0-15000 meters
    Conformance
    Approvals
    CSA C22.2 No. 60950 , IEC 60950 , METI Denan , UL 60950-1 , VDE
    Standard warranty
    2 years repair or replace
    Sustainable Offer Status
    RoHS
    Compliant
    REACH
    REACH: Contains No SVHCs
    Battery Directive
    Compliant
  • Atpakaļ

    Valoda
    • Latviešu
    • Slovenian
    • Danish
    • Lithuanian
    • Greek
    • Croatian
    • Serbian
    • Finnish
    • Norwegian
    • Dutch
    • English
    • Estonian
    Katalogs
    Datums 
    Izmērs
    Pievienot sadaļai Mani dokumenti
    Rack Power Distribution Unit (PDU) Pocket Guide (Versija 2)
    Lietotāja rokasgrāmata
    Datums 
    Izmērs
    Pievienot sadaļai Mani dokumenti
    Release Notes AP7XXXB, AP8XXX Rack PDUs AOS/APP V 6.6.4 (Versija 4)
    Metered Rack Power Distribution Unit (AP88XX) User Guide Firmware Version 5.X.X (Versija 4)
    MIB Reference Guide (Online Guide) (Versija 0)
    Datums  19.8.2
    Izmērs 122.1 KB
    Metered Rack Power Distribution Unit User Guide Firmware Version 6.6.4 (Versija 8)
    Release Notes Metered and Switched (AP8xxx) Rack Power Distribution Unit (PDU) v6.4.0 (Versija 8)
    Security Handbook Network Enabled Devices AOS V.6.5.X (Versija 1)
    Rack Power Distribution Unit (PDU) Installation Instructions (Versija 3)
    Security Handbook for APC Network Management Cards AOS v5.x.x (Versija 1)
    Rack Power Distribution Unit Display Module Installation (Versija 1)
    CAD faili
    Datums 
    Izmērs
    Pievienot sadaļai Mani dokumenti
    AP8858, EU3, NA3_Visio Stencil - Rack PDU 2G Metered Zero U (Versija 0)
    AP8858 - Rack PDU, Metered, ZeroU, 20A 208V, 16A 230V (Versija 2)
    Specifikācijas ceļvedis
    Datums 
    Izmērs
    Pievienot sadaļai Mani dokumenti
    Metered Rack PDU AP8858 Overview and Specifications (Versija 1)
    Sertifikāts
    Datums 
    Izmērs
    Pievienot sadaļai Mani dokumenti
    VDE Marks Approval License AP85xx, AP88xx, DELL68xx, series - 40028617 updated 2015-05-05 (Versija 1)
    VCCI 2009006747 AP88xx - VCCI-A approval - Issued 2010-02-18 (Versija 1)
    AP8858 KCC Approval (Versija 1)
    Datums  19.6.2
    Izmērs 201.5 KB
    VDE CB Test Certificate AP8800 series - DE1-50269 Issued 2012-07-11 (Versija 1)
    DENAN approval for <125 V input PDU (Versija 0)
    Datums  16.7.5
    Izmērs 846.3 KB
    Datums  16.7.5
    Izmērs 846.7 KB
    NBK270117-JP1042B - DENAN PSE Approval Multiple Socket Outlet rPDU (Versija 0)
    ACMA Supplier's DoC - Rack Power Distribution Units (Versija 0)
    EAC for Russian Customs Union - Rack PDUs and In Line Current Meters (Versija 2)
    NBK270117-JP1042A - DENAN PSE Approval Multiple Socket Outlet rPDU (Versija 0)
    CCC Exemption Letter (Versija 2)
    Datums  19.7.2
    Izmērs 4.4 MB
    EI1490-1 EMC Certficate and Report for NextGen Metered Rack PDU - Issued 2010-02-09 (Versija 1)
    E177299-A17-UL Notice of Authorization - NextGen AP8xxx and DELL6xxx rPDU (Versija 1)
    Instrukcijas lapa
    Datums 
    Izmērs
    Pievienot sadaļai Mani dokumenti
    Next Generation Rack Power Distribution Unit (PDU) Installation Instructions (Versija 0)
    Rack Power Distribution Unit (PDU) Safety Information (Versija 7)
    Informācija par ekspluatācijas izbeigšanu
    Datums 
    Izmērs
    Pievienot sadaļai Mani dokumenti
    EoLi - Metered Rack PDUs (Versija 0)
    Datums  19.9.2
    Izmērs 303.6 KB
    Produkta ietekme uz vidi
    Datums 
    Izmērs
    Pievienot sadaļai Mani dokumenti
    ePEP - Metered Rack PDUs (Versija 0)
    Datums  19.9.2
    Izmērs 366.4 KB