variable speed drive ATV212 - 15kW - 20hp - 240V - 3 ph - wo EMC - IP21

Show more characteristics >
Add to My Products Remove from My Products
The maximum number of products that can be compared is 4

  • Main
    range of product
    Altivar 212
    product or component type
    Variable speed drive
    device short name
    ATV212
    product destination
    Asynchronous motors
    product specific application
    Pumps and fans in HVAC
    assembly style
    With heat sink
    network number of phases
    3 phases
    motor power kW
    15 kW
    motor power hp
    20 hp
    [Us] rated supply voltage
    200...240 V - 15...10 %
    supply voltage limits
    170…264 V
    supply frequency
    50...60 Hz - 5...5 %
    network frequency
    47.5...63 Hz
    EMC filter
    Without EMC filter
    line current
    45.5 A at 240 V
    56.1 A at 200 V
    Complementary
    apparent power
    23.2 kVA at 240 V
    prospective line Isc
    22 kA
    continuous output current
    61 A at 230 V
    maximum transient current
    67.1 A for 60 s
    speed drive output frequency
    0.5…200 Hz
    nominal switching frequency
    12 kHz
    switching frequency
    6...16 kHz adjustable
    12...16 kHz with derating factor
    speed range
    1…10
    speed accuracy
    +/- 10 % of nominal slip 0.2 Tn to Tn
    torque accuracy
    +/- 15 %
    transient overtorque
    120 % of nominal motor torque +/- 10 % for 60 s
    asynchronous motor control profile
    Flux vector control without sensor, standard
    Voltage/frequency ratio, 5 points
    Voltage/frequency ratio, automatic IR compensation (U/f + automatic Uo)
    Voltage/frequency ratio, 2 points
    Voltage/frequency ratio - Energy Saving, quadratic U/f
    regulation loop
    Adjustable PI regulator
    motor slip compensation
    Automatic whatever the load
    Adjustable
    Not available in voltage/frequency ratio motor control
    local signalling
    DC bus energized: 1 LED (red)
    output voltage
    <= power supply voltage
    isolation
    Electrical between power and control
    type of cable
    Without mounting kit: 1 wire(s)IEC cable at 45 °C, copper 90 °C / XLPE/EPR
    Without mounting kit: 1 wire(s)IEC cable at 45 °C, copper 70 °C / PVC
    With UL Type 1 kit: 3 wire(s)UL 508 cable at 40 °C, copper 75 °C / PVC
    electrical connection
    VIA, VIB, FM, FLA, FLB, FLC, RY, RC, F, R, RES: terminal 2.5 mm² / AWG 14
    L1/R, L2/S, L3/T: terminal 25 mm² / AWG 3
    tightening torque
    0.6 N.m (VIA, VIB, FM, FLA, FLB, FLC, RY, RC, F, R, RES)
    4.5 N.m, 40 lb.in (L1/R, L2/S, L3/T)
    supply
    Internal supply for reference potentiometer (1 to 10 kOhm): 10.5 V DC +/- 5 %, <10 A, protection type: overload and short-circuit protection
    Internal supply: 24 V DC (21…27 V), <200 A, protection type: overload and short-circuit protection
    analogue input number
    2
    analogue input type
    VIA switch-configurable voltage: 0...10 V DC 24 V max, impedance: 30000 Ohm, resolution 10 bits
    VIB configurable voltage: 0...10 V DC 24 V max, impedance: 30000 Ohm, resolution 10 bits
    VIB configurable PTC probe: 0...6 probes, impedance: 1500 Ohm
    VIA switch-configurable current: 0...20 mA, impedance: 250 Ohm, resolution 10 bits
    sampling duration
    2 ms +/- 0.5 ms F discrete
    2 ms +/- 0.5 ms R discrete
    2 ms +/- 0.5 ms RES discrete
    3.5 ms +/- 0.5 ms VIA analog
    22 ms +/- 0.5 ms VIB analog
    response time
    FM 2 ms, tolerance +/- 0.5 ms for analog output(s)
    FLA, FLC 7 ms, tolerance +/- 0.5 ms for discrete output(s)
    FLB, FLC 7 ms, tolerance +/- 0.5 ms for discrete output(s)
    RY, RC 7 ms, tolerance +/- 0.5 ms for discrete output(s)
    accuracy
    +/- 0.6 % (VIA) for a temperature variation 60 °C
    +/- 0.6 % (VIB) for a temperature variation 60 °C
    +/- 1 % (FM) for a temperature variation 60 °C
    linearity error
    VIA: +/- 0.15 % of maximum value for input
    VIB: +/- 0.15 % of maximum value for input
    FM: +/- 0.2 % for output
    analogue output number
    1
    analogue output type
    FM switch-configurable voltage 0...10 V DC, impedance: 7620 Ohm, resolution 10 bits
    FM switch-configurable current 0...20 mA, impedance: 970 Ohm, resolution 10 bits
    discrete output number
    2
    discrete output type
    Configurable relay logic: (FLA, FLC) NO - 100000 cycles
    Configurable relay logic: (FLB, FLC) NC - 100000 cycles
    Configurable relay logic: (RY, RC) NO - 100000 cycles
    minimum switching current
    3 mA at 24 V DC for configurable relay logic
    maximum switching current
    5 A at 250 V AC on resistive load - cos phi = 1 - L/R = 0 ms (FL, R)
    5 A at 30 V DC on resistive load - cos phi = 1 - L/R = 0 ms (FL, R)
    2 A at 250 V AC on inductive load - cos phi = 0.4 - L/R = 7 ms (FL, R)
    2 A at 30 V DC on inductive load - cos phi = 0.4 - L/R = 7 ms (FL, R)
    discrete input type
    F programmable 24 V DC, with level 1 PLC, impedance: 4700 Ohm
    R programmable 24 V DC, with level 1 PLC, impedance: 4700 Ohm
    RES programmable 24 V DC, with level 1 PLC, impedance: 4700 Ohm
    discrete input logic
    Positive logic (source) (F, R, RES), <= 5 V (state 0), >= 11 V (state 1)
    Negative logic (sink) (F, R, RES), >= 16 V (state 0), <= 10 V (state 1)
    acceleration and deceleration ramps
    Automatic based on the load
    Linear adjustable separately from 0.01 to 3200 s
    braking to standstill
    By DC injection
    protection type
    Overheating protection: drive
    Thermal power stage: drive
    Short-circuit between motor phases: drive
    Input phase breaks: drive
    Overcurrent between output phases and earth: drive
    Overvoltages on the DC bus: drive
    Break on the control circuit: drive
    Against exceeding limit speed: drive
    Line supply overvoltage and undervoltage: drive
    Line supply undervoltage: drive
    Against input phase loss: drive
    Thermal protection: motor
    Motor phase break: motor
    With PTC probes: motor
    dielectric strength
    2830 V DC between earth and power terminals
    4230 V DC between control and power terminals
    insulation resistance
    >= 1 mOhm 500 V DC for 1 minute
    frequency resolution
    Display unit: 0.1 Hz
    Analog input: 0.024/50 Hz
    communication port protocol
    APOGEE FLN
    METASYS N2
    Modbus
    LonWorks
    BACnet
    connector type
    1 RJ45
    1 open style
    physical interface
    2-wire RS 485
    transmission frame
    RTU
    transmission rate
    9600 bps or 19200 bps
    data format
    8 bits, 1 stop, odd even or no configurable parity
    type of polarization
    No impedance
    number of addresses
    1…247
    communication service
    Write multiple registers (16) 2 words maximum
    Write single register (06)
    Read holding registers (03) 2 words maximum
    Time out setting from 0.1 to 100 s
    Read device identification (43)
    Monitoring inhibitable
    option card
    Communication card for LonWorks
    operating position
    Vertical +/- 10 degree
    width
    245 mm
    height
    330 mm
    depth
    190 mm
    net weight
    11.55 kg
    power dissipation in W
    629 W
    air flow
    215 m3/h
    specific application
    HVAC
    IP degree of protection
    IP21
    Motor power range AC-3
    15…25 kW at 200…240 V 3 phases
    motor starter type
    Variable speed drive
    Environment
    electromagnetic compatibility
    Electrostatic discharge immunity test level 3 conforming to IEC 61000-4-2
    Radiated radio-frequency electromagnetic field immunity test level 3 conforming to IEC 61000-4-3
    Electrical fast transient/burst immunity test level 4 conforming to IEC 61000-4-4
    1.2/50 µs - 8/20 µs surge immunity test level 3 conforming to IEC 61000-4-5
    Conducted radio-frequency immunity test level 3 conforming to IEC 61000-4-6
    Voltage dips and interruptions immunity test conforming to IEC 61000-4-11
    pollution degree
    2 conforming to IEC 61800-5-1
    IP degree of protection
    IP20 on upper part without blanking plate on cover conforming to EN/IEC 61800-5-1
    IP20 on upper part without blanking plate on cover conforming to EN/IEC 60529
    IP21 conforming to EN/IEC 61800-5-1
    IP21 conforming to EN/IEC 60529
    IP41 on upper part conforming to EN/IEC 61800-5-1
    IP41 on upper part conforming to EN/IEC 60529
    vibration resistance
    1.5 mm (f= 3…13 Hz) conforming to EN/IEC 60068-2-6
    1 gn (f= 13…200 Hz) conforming to EN/IEC 60068-2-8
    shock resistance
    15 gn for 11 ms conforming to IEC 60068-2-27
    environmental characteristic
    Classes 3C1 conforming to IEC 60721-3-3
    Classes 3S2 conforming to IEC 60721-3-3
    noise level
    54 dB conforming to 86/188/EEC
    operating altitude
    1000...3000 m limited to 2000 m for the Corner Grounded distribution network with current derating 1 % per 100 m
    <= 1000 m without
    relative humidity
    5…95 % without condensation conforming to IEC 60068-2-3
    5…95 % without dripping water conforming to IEC 60068-2-3
    ambient air temperature for operation
    -10…40 °C (without)
    40…50 °C (with derating factor)
    ambient air temperature for storage
    -25…70 °C
    standards
    EN 61800-3 environments 1 category C2
    IEC 61800-3 environments 2 category C1
    IEC 61800-5-1
    EN 61800-3 environments 2 category C1
    EN 61800-5-1
    EN 61800-3 environments 1 category C1
    IEC 61800-3 environments 1 category C1
    IEC 61800-3 environments 2 category C3
    IEC 61800-3 environments 1 category C2
    EN 61800-3 environments 2 category C2
    EN 61800-3 environments 2 category C3
    IEC 61800-3 environments 2 category C2
    EN 61800-3 environments 1 category C3
    IEC 61800-3 environments 1 category C3
    UL Type 1
    EN 61800-3
    IEC 61800-3
    product certifications
    C-Tick
    NOM 117
    CSA
    UL
    marking
    CE
    Offer Sustainability
    Sustainable offer status
    Green Premium product
    REACh Regulation
    EU RoHS Directive
    Pro-active compliance (Product out of EU RoHS legal scope)
    EU RoHS Declaration
    Mercury free
    Yes
    RoHS exemption information
    China RoHS Regulation
    Environmental Disclosure
    Circularity Profile
    WEEE
    The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins
    Contractual warranty
    Warranty
    18 months
  • Documents and Downloads

    Language
    • English
    • Spanish
    • Slovenian
    • Danish
    • Ukrainian
    • French
    • Chinese
    • Hungarian
    • Norwegian
    • Dutch
    • Turkish
    • Korean
    • Portuguese
    • Russian
    • Lithuanian
    • Greek
    • Croatian
    • Italian
    • German
    • Swedish
    • Bulgarian
    DTM files
    Date
    Size
    Add to My Documents
    Altivar DTM Library V12.8: ATV12, ATV31/312, ATV32, ATV61, ATV71, ATV LIFT, ATV212 (Version 12.8)
    Catalogue
    Date
    Size
    Add to My Documents
    Altivar 212 variable drives 2011/03 (web PDF format) (Version 1.1)
    User guide
    Date
    Size
    Add to My Documents
    ATV212 BACnet manual (Version 03)
    Date 4/11/17
    Size 978.7 KB
    3) ATV212 Programming Manual (Version 03)
    Date 11/7/14
    Size 3.5 MB
    ATV212 Modbus manual (Version 02)
    Date 9/28/12
    Size 1.1 MB
    2) ATV212 Installation manual (Version 04)
    Date 3/19/19
    Size 6.1 MB
    CAD
    Date
    Size
    Add to My Documents
    CAD file (on TraceParts) for ATV212HD15M3X: variable speed drive ATV212 - 15kW - 20hp - 240V - 3 ph - wo EMC - IP21 (Version 2.0)
    CAD for ATV212HD15M3X: variable speed drive ATV212 - 15kW - 20hp - 240V - 3 ph - wo EMC - IP21 (Version 1.0)
    Certificate
    Date
    Size
    Add to My Documents
    ATV212 EU DECLARATION (Version 1.0)
    Date 4/20/16
    Size 682.4 KB
    ATV21-212 UL CERTIFICATE (Version 1.0)
    Date 3/16/12
    Size 2.3 MB
    ATV21-212 CSA CERTIFICATE (Version 1.0)
    Date 7/10/18
    Size 120 KB
    Instruction sheet
    Date
    Size
    Add to My Documents
    Instruction sheet - Fan: VZ3V3101, VZ3V3102 (Version 04)
    EU RoHS Declaration
    Date
    Size
    Add to My Documents
    Product Environmental Profile
    Date
    Size
    Add to My Documents
    ATV212H... Altivar 212 range: 0.75 to 18.5 kW – IP21, Profil environnemental produit (Version 1.0)
    REACh Declaration
    Date
    Size
    Add to My Documents
    RoHs China Declaration
    Date
    Size
    Add to My Documents
  • Technical FAQs

    No results found.
    Unfortunately, related FAQs are unavailable due to temporary technical issues. Please try again later.
  • Dimensions Drawings

    Dimensions


    Plate for EMC mounting (supplied with the drive)


    (1)
    2 x M5 screws


  • Mounting and Clearance

    Mounting Recommendations
    Clearance

    Depending on the conditions in which the drive is to be used, its installation will require certain precautions and the use of appropriate accessories.

    Install the unit vertically:

    • Do not place it close to heating elements.

    • Leave sufficient free space to ensure that the air required for cooling purposes can circulate from bottom to the top of the unit.


    Mounting Types

    Type A mounting


    Type B mounting


    Type C mounting


    By removing the protective blanking cover from the top of the drive, the degree of protection for the drive becomes IP21. The protective blanking cover may vary according to the drive model, see opposite.


    Specific Recommendations for Mounting in an Enclosure

    To help ensure proper air circulation in the drive:

    • Fit ventilation grilles.

    • Check that there is sufficient ventilation. If there is not, install a forced ventilation unit with a filter. The openings and/or fans must provide a flow rate at least equal to that of the drive fans (refer to the product characteristics).

    • Use special filters with UL Type 12/IP54 protection.

    • Remove the blanking cover from the top of the drive.

    Sealed Metal Enclosure (IP54 Degree of Protection)

    The drive must be mounted in a dust and damp proof enclosure in certain environmental conditions, such as dust, corrosive gases, high humidity with risk of condensation and dripping water, splashing liquid, etc.This enables the drive to be used in an enclosure where the maximum internal temperature reaches 50°C.


  • Connections and Schema

    Recommended Wiring Diagram
    3-Phase Power Supply


    A1:
    ATV 212 drive
    KM1:
    Contactor
    Q1:
    Circuit breaker
    Q2:
    GV2 L rated at twice the nominal primary current of T1
    Q3:
    GB2CB05
    S1, S2:
    XB4 B or XB5 A pushbuttons
    T1:
    100 VA transformer 220 V secondary
    (1)
    Fault relay contacts for remote signalling of the drive status
    (2)
    Connection of the common for the logic inputs depends on the positioning of the switch (Source, PLC, Sink)
    (3)
    Reference potentiometer SZ1RV1202

    NOTE: All terminals are located at the bottom of the drive. Install interference suppressors on all inductive circuits near the drive or connected on the same circuit, such as relays, contactors, solenoid valves, fluorescent lighting, etc.

    Switches (Factory Settings)

    Voltage/current selection for analog I/O (VIA and VIB)


    Voltage/current selection for analog I/O (FM)


    Selection of logic type


    (1)
    negative logic
    (2)
    positive logic


    Other Possible Wiring Diagrams
    Logic Inputs According to the Position of the Logic Type Switch

    “Source” position


    “Sink” position


    “PLC” position with PLC transistor outputs


    (1)
    PLC


    (1)
    PLC

    2-wire control


    F:
    Forward
    R:
    Preset speed
    (2)
    ATV 212 control terminals

    3-wire control


    F:
    Forward
    R:
    Stop
    RES:
    Reverse
    (2)
    ATV 212 control terminals

    PTC probe


    (2)
    ATV 212 control terminals
    (3)
    Motor

    Analog Inputs

    Voltage analog inputs

    External +10 V


    (2)
    ATV 212 control terminals
    (4)
    Speed reference potentiometer 2.2 to 10 kΩ


    (2)
    ATV 212 control terminals

    Analog input configured for current: 0-20 mA, 4-20 mA, X-Y mA


    (2)
    ATV 212 control terminals
    (5)
    Source 0-20 mA, 4-20 mA, X-Y mA

    Analog input VIA configured as positive logic input (“Source” position)


    (2)
    ATV 212 control terminals

    Analog input VIA configured as negative logic input (“Sink” position)


    (2)
    ATV 212 control terminals


  • Performance Curves

    Derating Curves

    The derating curves for the drive nominal current (In) depend on the temperature, the switching frequency and the mounting type (A, B or C).

    For intermediate temperatures (45°C for example), interpolate between 2 curves.


    X
    Switching frequency