{"support":{"yesButton":"Ja","noButton":"Nee","feedback":{"title":"Wat kunnen we doen om dit te verbeteren?"},"submitButton":"Verzenden","successMessage":"Bedankt voor uw feedback","title":"Bent u geholpen met deze informatie ?","feedbackPercentLabel":"van de mensen vonden dit nuttig","captcha":{"error":"Vink het vakje aan"}}}
Veelgestelde vragen (FAQ's) zoeken

Video: How to configure the XVUC9V sound module for XVU tower light?

Product range:  Harmony XVU modular tower lights
 
The XVUC9V soundmodule of the Harmony XVU towerlight can play voice message when customer inputs PLC signal.
You can customize voices and messages with an SD card and the Schneider Electric “Playlist Builder” software.

Please take a look at the video:


 

The “Playlist Builder” software is free downloadable from the Schneider Electric website:
https://www.se.com/ww/en/download/document/PlaylistBuilderV1.0.2/
or:
https://www.se.com/nl/nl/download/document/PlaylistBuilderV1.0.2/

Copy the files from the “Playlist Builder” software to your SD card.
When, after inserting the SD card into the XVUC9V unit, you hear a sound “Pi, PiPiPi” an error occured. 
Potential errors:

 
  • No Playlist detected
  • No correct Playlist ( version, model ) detected
  • SD card is not supported of SD card is broken
  • SD card has been extracted / not properly inserted
If you hear the sound “Pi” and after 30 sec the sound “Piiiii” the download into the XVU unit is successful
and the SD card can be extracted from the unit.

In the attachment you will find the XVUC9V instruction sheet/troubleshooting guide


 