New Zealand
Welcome to the Schneider Electric Website

Welcome to our website.

You can choose another country to view available products or go to our Global website for company information.

Choose another country or region

Unity Hot Standby processor with single mode Ethernet - 3072 kB - 266 MHz

Show more characteristics >
Add to My Products Remove from My Products
The maximum number of products that can be compared is 4

  • Main
    range of product
    Modicon Quantum automation platform
    product or component type
    Unity processor
    Complementary
    mode of transmission
    Single mode
    clock frequency
    266 MHz
    number of slots
    16
    10
    6
    2
    4
    number of racks
    2 - local rack(s)
    number of distributed I/O station
    63 station(s) - 1 rack(s) - 3 Modbus Plus network(s)
    number of remote I/O station
    31 - 2 rack(s) per S908 remote I/O
    31 - 2 rack(s) per ethernet Quantum remote I/O
    31 - 2 rack(s) per ethernet X80 remote I/O
    discrete I/O number
    31744 inputs, 31744 outputs - remote
    8000 inputs, 8000 outputs - distributed - per network Modbus Plus
    Unlimited (31 drops of 28 slots max) - ethernet remote I/O
    0 - local - forbidden in Hot Standby application
    analogue I/O number
    500 inputs, 500 outputs - distributed - per network Modbus Plus
    Unlimited (31 drops of 28 slots max) - ethernet remote I/O
    1984 inputs,1984 outputs - remote
    0 - local - forbidden in Hot Standby application
    application specific I/O
    Serial link
    Accurate time stamping
    High-speed interrupt inputs
    Counter
    communication service
    Ethernet router
    number of optional modules
    6 (Ethernet, Modbus, Modbus Plus, Profibus DP, Sy/Max)
    maximum number of connections
    1 USB
    2 AS-Interface - distributed
    4 AS-Interface - remote
    6 Ethernet TCP/IP - local
    6 Modbus Plus - local
    6 Profibus DP - local
    1 Modbus (RS232/485 Modbus/ASCII)
    integrated connection type
    1 Modbus Plus with
    1 Modbus with
    1 USB with
    1 optic fibre with Hot Standby
    checks
    Hot standby
    Process control
    memory description
    Expandable 7168 kB - program with PCMCIA card
    Expandable 8 MB - file storage with PCMCIA card
    Internal RAM 3072 kB - 1536 kB for data
    switch function
    Key switch memory port on/off
    application structure
    1 periodic fast task - forbidden in Hot Standby application
    128 I/O interrupt tasks - forbidden in Hot Standby application
    128 interrupt tasks - forbidden in Hot Standby application
    32 timer interrupt tasks - forbidden in Hot Standby application
    4 auxiliary tasks - forbidden in Hot Standby application
    1 cyclic/periodic master task -
    number of instructions per ms
    10.28 Kinst/ms 100 % Boolean
    10.07 Kinst/ms 65 % Boolean and 35 % numerical
    system overhead
    0.2 ms for fast task
    1 ms for master task
    bus current requirement
    2760 mA
    local signalling
    Ethernet activity (COM): 1 LED (green)
    Ethernet collision: 1 LED (red)
    electrical connection
    1 female connector, connector type: SUB-D 9 for connecting to the Modbus Plus network
    1 connector, connector type: RJ45 for connecting Modbus bus
    1 connector, connector type: LC (single mode fiber optic) for interconnecting primary and secondary PLCs up to 16 km
    Environment
    product certifications
    Misc (Marine)
    GOST
    UL
    CE
    CSA
    standards
    HazLoc
    Offer Sustainability
    Sustainable offer status
    Green Premium product
    EU RoHS Directive
    Pro-active compliance (Product out of EU RoHS legal scope)
    EU RoHS Declaration
    Environmental Disclosure
    Circularity Profile
    Contractual warranty
    Warranty
    18 months
  • Documents & Downloads

    Language
    • English
    • French
    Catalogue
    Date
    Size
    Add to My Documents
    Modicon Quantum automation platform - English version 2015/11 (web pdf format) (Version 3.0)
    User guide
    Date
    Size
    Add to My Documents
    140CPU651.0 / 65260 / 67160 / 67261 High performance CPUs (Version 11)
    Quantum using EcoStruxure™ Control Expert - Hot Standby System, User Manual (Version 16)
    EcoStruxure™ Control Expert - Operating Modes (Version 22)
    Quantum using EcoStruxure™ Control Expert - Hardware Reference Manual (Version 18)
    EcoStruxure™ Control Expert - OS Loader, User Manual (Version 16)
    Quantum using EcoStruxure™ Control Expert - Change Configuration On The Fly, User Guide (Version 10)
    CAD
    Date
    Size
    Add to My Documents
    CAD for 140CPU67261: Unity Hot Standby processor with single mode Ethernet - 3072 kB - 266 MHz (Version 1.0)
    Certificate
    Date
    Size
    Add to My Documents
    HazLoc_cCSAus_225844_70108543_Quantum_may2017 (Version 1.0)
    CLASS - C225351 - PROGRAMMABLE CONTROLLER,CLASS - C225802 - PROCESS CONTROL EQUIPMENT-For Hazardous Locations (Version 1.0)
    UL E486184 - NRAQ-NRAQ7 (Version 1.0)
    Date 12/12/18
    Size 395.6 KB
    Instruction sheet
    Date
    Size
    Add to My Documents
    Quantum High End & Legacy Operating system Upgrade Procedure (Version 1)
    Declaration of conformity
    Date
    Size
    Add to My Documents
    ACMA_RCM_QUANTUM_AUG2017 (Version 1.0)
    Date 28/11/17
    Size 233.5 KB
    DCC_QUANTUM_APR2017 (Version 1.0)
    Date 7/04/17
    Size 510.4 KB
    End of Life Information
    Date
    Size
    Add to My Documents
    Modicon Quantum automation platform, Product End-of-Life Instructions (Version 1.0)
    EU RoHS Declaration
    Date
    Size
    Add to My Documents
    Firmware - Updates
    Date
    Size
    Add to My Documents
    Quantum 140CPU67261 Operating System (Version 3.523)
    Quantum HotStandby Last Firmware History (Version 3.42)
    Quantum HSBY High End Last Firmware History including (Version 3.53)
    Marine certificate
    Date
    Size
    Add to My Documents
    BV_13682_C0_Quantum_MAY2018 (Version 1.0)
    Date 22/05/18
    Size 400 KB
    RMRS Marine Certificate QUANTUM PLCs (Version 1.0)
    ABS Marine Certificate QUANTUM PLCs (Version 1.0)
    MERCHANT_NAVY_PLC_INSTALLATION (Version 1.0)
    Date 11/01/19
    Size 181.4 KB
    RINA Marine Certificate QUANTUM PLCs (Version 1.0)
    LR_04.00057E1_QUANTUM_MAY2016 (Version 1.0)
    Date 18/05/16
    Size 504.7 KB
    Date 18/05/16
    Size 68 KB
    DNV-GL Marine Certificate QUANTUM PLCs (Version 1.0)
    REACh Declaration
    Date
    Size
    Add to My Documents
  • Technical FAQs

    No results found.
    Unfortunately, related FAQs are unavailable due to temporary technical issues. Please try again later.
  • Dimensions Drawings

    Racks for Modules Mounting
    Dimensions of Modules and Racks


    (1)
    2 slots
    (2)
    3 slots
    (3)
    4 slots
    (4)
    6 slots
    (5)
    10 slots
    (6)
    16 slots


Compare products: /