Slika proizvoda AP8853 Schneider Electric

Prikaži sve Metered Rack PDU

Metered Rack PDU - AP8853

Slika proizvoda AP8853 Schneider Electric
Prikaži sve Metered Rack PDU
Metered Rack PDU - AP8853

Rack PDU 2G, Metered, ZeroU, 32A, 230V, (36) C13 & (6) C19

Prikaži još karakteristika >
Dodaj u moje proizvode Ukloni iz Mojih proizvoda

  • Overview
    Description
    APC Metered Rack Power Distribution Units (PDUs) provide active metering to enable energy optimization and circuit protection. User-defined alarm thresholds mitigate risk with real-time local and remote alerts to warn of potential circuit overloads. Metered Rack PDUs provide power utilization data to allow Data Center Managers to make informed decisions on load balancing and right sizing IT environments to lower total cost of ownership. Metered Rack PDUs include real power monitoring, a temperature/humidity sensor port, locking IEC receptacles, and ultra low profile circuit breakers. Users can access and configure Metered Rack PDUs through secure Web, SNMP, or Telnet Interfaces which are complimented by APC Centralized Management platforms using InfraStruxure Central, Operations, Capacity, and Energy Efficiency.
    Model Name
    Rack PDU 2G, Metered, ZeroU, 32A, 230V, (36) C13 & (6) C19
    Includes
    Installation guide , Rack Mounting brackets , Safety guide , Serial configuration cable
    Standard Lead Time
    Usually in Stock
    Product Distribution
    Afghanistan , Albania , Algeria , Andorra , Angola , Anguilla , Antigua And Barbuda , Argentina , Armenia , Aruba , Australia , Austria , Azerbaijan , Bahamas , Bahrain , Bangladesh , Barbados , Belarus , Belgium , Belize , Benin , Bermuda , Bhutan , Bolivia , Bosnia And Herzegovina , Botswana , Brazil , Brunei Darussalam , Bulgaria , Burkina Faso , Burundi , Cambodia , Cameroon , Cayman Islands , Central African Republic , Chad , Chile , China , Colombia , Congo , CONGO, THE DEMOCRATIC REPUBLIC OF THE , Cook Islands , Costa Rica , Cote D'Ivoire , Croatia , Cuba , Cyprus , Czech Republic , Denmark , Djibouti , Dominica , Dominican Republic , East Timor , Ecuador , Egypt , El Salvador , Equatorial Guinea , Eritrea , Estonia , Ethiopia , Falkland Islands (Malvinas) , Fiji , Finland , France , Gabon , Gambia , Georgia , Germany , Ghana , Gibraltar , Greece , Grenada , Guatemala , Guinea , Guyana , Haiti , Honduras , Hong Kong , Hungary , Iceland , India , Indonesia , Iran (Islamic Republic Of) , Iraq , Ireland , Israel , Italy , Jamaica , Jordan , Kazakhstan , Kenya , KOREA, REPUBLIC OF , Kuwait , Latvia , Lebanon , Lesotho , Liberia , Liechtenstein , Lithuania , Luxembourg , Macedonia , Malawi , Malaysia , Mali , Malta , Mauritania , Mexico , Moldova, Republic Of , Mongolia , Morocco , Mozambique , Myanmar , Namibia , Nepal , Netherlands , Netherlands Antilles , New Zealand , Nicaragua , Niger , Nigeria , Norway , Oman , Pakistan , Panama , Papua New Guinea , Paraguay , Peru , Philippines , Poland , Portugal , Puerto Rico , Romania , Russian Federation , Rwanda , SAINT KITTS AND NEVIS , SAINT LUCIA , SAINT VINCENT AND THE GRENADINES , Saudi Arabia , Senegal , Sierra Leone , Singapore , Slovakia (Slovak Republic) , Slovenia , Somalia , South Africa , Spain , Sri Lanka , Sudan , Suriname , Sweden , Switzerland , Taiwan , Tajikistan , TANZANIA, UNITED REPUBLIC OF , Thailand , Togo , Trinidad And Tobago , Turkey , Turkmenistan , Uganda , Ukraine , United Arab Emirates , Uruguay , Uzbekistan , Venezuela , Viet Nam , VIRGIN ISLANDS (UNITED STATES) , Western Sahara , Yemen , Zambia , Zimbabwe
    Output
    Nominal Output Voltage
    230V
    Maximum Total Current Draw per Phase
    32 A
    Output Connections
    (36) IEC 320 C13 (Battery Backup) , (6) IEC 320 C19 (Battery Backup)
    Overload Protection
    Yes
    Input
    Nominal Input Voltage
    200V , 208V , 230V
    Input Frequency
    50/60 Hz
    Input Connections
    IEC 309 32A 2P+E
    Cord Length
    3 meters
    Number of Power Cords
    1
    Acceptable Input Voltage
    220-240 VAC
    Maximum Line Current per phase
    32 A
    Maximum Input Current per phase
    32 A
    Physical
    Net Weight
    6.93 kg
    Maximum Height
    1791.0 mm
    Maximum Width
    56.0 mm
    Maximum Depth
    44.0 mm
    Shipping Weight
    8.56 kg
    Shipping Height
    2000.0 mm
    Shipping Width
    162.0 mm
    Shipping Depth
    107.0 mm
    Color
    Black
    Environmental
    Operating Environment
    -5 - 45 °C
    Operating Relative Humidity
    5 - 95 %
    Operating Elevation
    0-3000 meters
    Storage Temperature
    -25 - 65 °C
    Storage Relative Humidity
    5 - 95 %
    Storage Elevation
    0-15000 meters
    Conformance
    Approvals
    IEC 60950 , VDE
    Standard warranty
    2 years repair or replace
    Sustainable Offer Status
    RoHS
    Compliant
    REACH
    REACH: Contains No SVHCs
    Battery Directive
    Compliant
  • Dokumenti i preuzimanja

    Jezik
    • Српски
    • Енглески
    Katalog
    Datum
    Veličina
    Dodaj u Moje dokumente
    Rack Power Distribution Unit (PDU) Pocket Guide (Verzija 2)
    APC Modular Power Distribution, Modular Power Accessories, and Rack PDUs: 400V Compatibility Chart (Verzija 5)
    Uputstvo za upotrebu
    Datum
    Veličina
    Dodaj u Moje dokumente
    Metered Rack Power Distribution Unit (AP88XX) User Guide Firmware Version 5.X.X (Verzija 4)
    Security Handbook for APC Network Management Cards AOS v5.x.x (Verzija 1)
    Metered Rack Power Distribution Unit User Guide Firmware Version 6.6.4 (Verzija 8)
    Release Notes Metered and Switched (AP8xxx) Rack Power Distribution Unit (PDU) v6.4.0 (Verzija 8)
    MIB Reference Guide (Online Guide) (Verzija 0)
    Datum 8.2.19.
    Veličina 122.1 KB
    Security Handbook Network Enabled Devices AOS V.6.5.X (Verzija 1)
    Rack Power Distribution Unit (PDU) Installation Instructions (Verzija 3)
    Rack Power Distribution Unit Display Module Installation (Verzija 1)
    Release Notes AP7XXXB, AP8XXX Rack PDUs AOS/APP V 6.6.4 (Verzija 4)
    CAD
    Datum
    Veličina
    Dodaj u Moje dokumente
    AP8853 - Rack PDU, Metered, ZeroU, 32A, 230V (Verzija 2)
    AP8853_Visio Stencil - Rack PDU 2G Metered Zero U (Verzija 0)
    Vodič za specifikaciju
    Datum
    Veličina
    Dodaj u Moje dokumente
    Metered Rack PDU AP8853 Overview and Specifications (Verzija 0)
    Sertifikat
    Datum
    Veličina
    Dodaj u Moje dokumente
    EAC for Russian Customs Union - Rack PDUs and In Line Current Meters (Verzija 2)
    VDE Marks Approval License AP85xx, AP88xx, DELL68xx, series - 40028617 updated 2015-05-05 (Verzija 1)
    EI1490-1 EMC Certficate and Report for NextGen Metered Rack PDU - Issued 2010-02-09 (Verzija 1)
    CCC Exemption Letter (Verzija 2)
    Datum 7.2.19.
    Veličina 4.4 MB
    ACMA Supplier's DoC - Rack Power Distribution Units (Verzija 0)
    AP8853 KTC approval for Korea (Verzija 1)
    Datum 8.2.19.
    Veličina 199 KB
    VDE CB Test Certificate AP8800 series - DE1-50269 Issued 2012-07-11 (Verzija 1)
    Uputstvo za montažu
    Datum
    Veličina
    Dodaj u Moje dokumente
    Rack Power Distribution Unit (PDU) Safety Information (Verzija 7)
    Next Generation Rack Power Distribution Unit (PDU) Installation Instructions (Verzija 0)
    Informacije o kraju radnog veka
    Datum
    Veličina
    Dodaj u Moje dokumente
    EoLi - Metered Rack PDUs (Verzija 0)
    Datum 9.2.19.
    Veličina 303.6 KB
    Profil ekološke prihvatljivosti proizvoda
    Datum
    Veličina
    Dodaj u Moje dokumente
    ePEP - Metered Rack PDUs (Verzija 0)
    Datum 9.2.19.
    Veličina 366.4 KB
  • Najčešća tehnička pitanja

    Nije pronađen nijedan rezultat.
    Nažalost, povezana najčešća pitanja nisu dostupna zbog privremenih tehničkih problema. Pokušajte ponovo kasnije.
Nos conseillers sont disponibles pour répondre à vos questions de 8h00 à 18h00 du lundi au vendredi toute l'année.