This manual is intended for users of Schneider Electric PLC systems during configuration and installation and provides information regarding grounding and measures for electromagnetic compatibility (EMC).
engelska
prp.document.label.formatpdf
Storlek3.3 MB
Datum2019-10-01
Beskrivning
This manual is intended for users of Schneider Electric PLC systems during configuration and installation and provides information regarding grounding and measures for electromagnetic compatibility (EMC).
This manual contains complete information about the Momentum I/O bases. It contains only passing references to other Momentum components, including processor adapters, option adapters, and communication adapters.
engelska
prp.document.label.formatpdf
Storlek4.4 MB
Datum2019-10-01
Beskrivning
This manual contains complete information about the Momentum I/O bases. It contains only passing references to other Momentum components, including processor adapters, option adapters, and communication adapters.
This manual describes the structure and the configuration of the fast counter module AEC 920. The different operating modes are explained using the applications as examples.
engelska
prp.document.label.formatpdf
Storlek942.6 KB
Datum2018-12-01
Beskrivning
This manual describes the structure and the configuration of the fast counter module AEC 920. The different operating modes are explained using the applications as examples.
This manual describes the functionality of the 170PNT Series Modbus Plus |Communication Adapters. The following |information is an introduction to this |manual. | |Function: The Modbus Plus communication |adapters can be connected to any Momentum I/O base to create a functional I/O module. |The adapters provide direct connection to |the Modbus Plus network, enabling a |programmable controller to communicate |with field devices wired to the I/O base |terminals. The controller on the network |can read from the input terminals and |write to the output terminals of the I/O |base using Modbus Plus Peer Cop or MSTR |Function Block messaging. | |Data Format: Data bits are transferred in |the IEC format. This is the standard data format for the Momentum product line. | |Models: Model 170PNT11020 has one Modbus |Plus port for connection to a network with a single trunk cable. Model 170PNT16020 has two ports for connection to either a single-cable or dual-cable network. |
engelska
prp.document.label.formatpdf
Storlek485 KB
Datum2010-05-01
Beskrivning
This manual describes the functionality of the 170PNT Series Modbus Plus |Communication Adapters. The following |information is an introduction to this |manual. | |Function: The Modbus Plus communication |adapters can be connected to any Momentum I/O base to create a functional I/O module. |The adapters provide direct connection to |the Modbus Plus network, enabling a |programmable controller to communicate |with field devices wired to the I/O base |terminals. The controller on the network |can read from the input terminals and |write to the output terminals of the I/O |base using Modbus Plus Peer Cop or MSTR |Function Block messaging. | |Data Format: Data bits are transferred in |the IEC format. This is the standard data format for the Momentum product line. | |Models: Model 170PNT11020 has one Modbus |Plus port for connection to a network with a single trunk cable. Model 170PNT16020 has two ports for connection to either a single-cable or dual-cable network. |
This document is aimed at users wishing to install and run dust and damp-proof
remote I/O modules on INTERBUS.
Details of the following aspects are given for each 16-input and 16-output module:
-- module presentation,
-- module installation,
-- module startup and maintenance.
The two modules must be controlled by an INTERBUS master module. They can only
be connected to an installation bus. Several module types may be used to connect
PLCs from the Schneider Automation catalog to an INTERBUS network.
engelska
prp.document.label.formatpdf
Storlek925.1 KB
Datum2003-12-01
Beskrivning
This document is aimed at users wishing to install and run dust and damp-proof
remote I/O modules on INTERBUS.
Details of the following aspects are given for each 16-input and 16-output module:
-- module presentation,
-- module installation,
-- module startup and maintenance.
The two modules must be controlled by an INTERBUS master module. They can only
be connected to an installation bus. Several module types may be used to connect
PLCs from the Schneider Automation catalog to an INTERBUS network.
Med portalen MySE kan du enkelt sköta dina beställningar hos oss. Du kan se pris och tillgänglighet, lägga order och se status på inneliggande beställningar.