Välkommen till Schneider Electrics webbplats

Välkommen till vår webbplats.

Välj din plats

Welcome the the Schneider Electric French website. It looks like you are located in the United States, would you like to change your location?

Traduisez en francais

eSetup Easergy Pro

Programvara till Easergy P3 för reläskyddsinställning och konfigurering.

Del av PowerLogic

Med eSetup Easergy Pro kan du konfigurera Easergy P3 reläskydd. eSetup Easergy Pro är intuitiv och enkel med ett användarvänligt gränssnitt som hjälper dig med konstruktion, beställning och drift av Easergy P3 reläskydd. Mjukvaran har ett strömlinjeformat arbetsflöde och grafisk visning för att förenkla din konfigurering.

eSetup Easergy Pro
  • Funktioner

    During engineering Create the configuration of the Easergy P3 relay, select the appropriate options and receive the order code Set the characteristics of the CTs, VTs, or sensors connected to the relay, and select the protection functions that will be activated and their settings Build specific logic conditions, if required, using a graphic editor Map the digital inputs (DI) and different internal signals to the relevant functions, LEDs, and digital outputs (DO), using a straightforward matrix format. Draw the single-line diagram (SLD) that will appear on the front display of the relay for switchgear control and select the measurements that will be displayed. If any, build the interlocking logic using a matrix format Configure IEC 61850 protocol data set and the report control blocks that will be published and select the GOOSE data to which you want to subscribe Complete the setting of additional functions (disturbance recorder, event logging system, clock synchronization, etc.).During commissioningCreate the configuration of the Easergy P3 relay: select the appropriate options and receive the order code Set the characteristics of the CTs, VTs, or sensors connected to the relay, and select the protection functions that will be activated and their settings Build specific logic conditions, if required, using a graphic editor Map the digital inputs (DI) and different internal signals to the relevant functions, LEDs, and digital outputs (DO), using a straightforward matrix format. Draw the single-line diagram that will appear on the front display of the relay for switchgear control and select the measurements that will be displayed. If any, build the interlocking logic using a matrix format Configure IEC 61850 protocol data set and the report control blocks that will be published and select the GOOSE data to which you want to subscribe Complete the setting of additional functions (disturbance recorder, event logging system, clock synchronization, etc.).During operationConnect to the front panel of a single relay or gain access to several relays by connecting to Ethernet Get the most of the metering capabilities during normal operation of the Easergy P3 protection relay: Navigate the different measurements menus to access the power monitoring and power quality data. Open the disturbance recorder menu to get a waveform capture or program the recording of a power trend. Understand a trip, using eSetup Easergy Pro to investigate the fault data Check the fault log of the protection that has tripped the circuit breaker Download the disturbance record from the Easergy P3 and display it with a disturbance recorder evaluation tool, eg. Wavewin.

    Galleri

    • Commissioning view
    • Engineering view
    • Operation view

EcoStruxure™ för din verksamhet

Med EcoStruxure kan du lyckas i dagens digitala värld. Gör bättre affärsbeslut med skalbara och integrerade IT/OT-lösningar.

MySE portalen

Med portalen MySE kan du enkelt sköta dina beställningar hos oss. Du kan se pris och tillgänglighet, lägga order och se status på inneliggande beställningar.