Welcome to the Schneider Electric Website

Welcome to our website.

Select your location

Welcome the the Schneider Electric French website. It looks like you are located in the United States, would you like to change your location?

Traduisez en francais
View all   Modicon Momentum
171CCC98020 Product picture

171CCC98020

171CCC98020 Product picture
171CCC98020

M1/M1E processor adaptor - 1 Ethernet, 1 Modbus - 50 MHz

Show more characteristics
The maximum number of products that can be compared is 4. Remove already added products.

  • Main
    range of product
    Modicon Momentum automation platform
    product or component type
    M1/M1E processor adaptor
    concept
    Transparent Ready
    level or class
    Class B10
    software designation
    Concept version V2.6
    Modsoft version >= V2.5
    ProWORX NxT version V2.0
    ProWORX 32
    communication port protocol
    Ethernet
    Modbus
    processor name
    X 86 based (INTEL, AMD)
    clock frequency
    50 MHz
    Complementary
    web services
    Web page loader software tool
    Web page loader
    Rack viewer
    Data editor
    Ethernet service
    I/O scanning
    Modbus TCP messaging
    discrete I/O processor capacity
    8192 I/8192 O
    memory type
    512 kB flash
    544 kB RAM
    memory description
    Program memory 18 kB LL984
    Data 24 kB
    material
    Lexan
    word length
    16 bit
    [Us] rated supply voltage
    5.0 V DC +/-5 %
    supply
    By Momentum I/O base
    exact time for 1 Kinstruction
    1 ms
    register I/O processor capacity
    26048 I/26048 O
    I/O limit processor capacity
    I/O local on Modbus
    number of port
    1 RS485
    1 Ethernet
    marking
    CE
    net weight
    0.042 kg
    Environment
    protective treatment
    TC
    ambient air temperature for operation
    0…60 °C
    ambient air temperature for storage
    -40…85 °C
    relative humidity
    5…96 % without condensation
    operating altitude
    2000 m
    shock resistance
    <= 15 gn peak 11 ms half sine wave acceleration
    vibration resistance
    1 gn
    0.75 mm d.a
    product certifications
    Nema type 250
    UL
    CUL
    FM Class 1 Division 2
    Packing Units
    Package 1 Weight
    0.211 kg
    Package 1 Height
    55.000 mm
    Package 1 width
    180.000 mm
    Package 1 Length
    260.000 mm
    Contractual warranty
    Warranty
    18 months
  • View more View less

    Documents

    Language
    • English1
    User guide
    Format
    Size
    Date
    Add to My Documents
    171CCC... / 171CCS... M1 Processor Adapter and Option Adapter (Version 10)
    Description
    This manual contains complete information about the Momentum M1 processor adapters, option adapters and Ethernet adapters. It does not contain information about Momentum I/O bases or communication adapters.
    prp.document.label.format pdf
    Size 3.6 MB
    Date 1/4/10
    Description
    This manual contains complete information about the Momentum M1 processor adapters, option adapters and Ethernet adapters. It does not contain information about Momentum I/O bases or communication adapters.
  • View more View less

    Software and Firmware

    Language
    • English2
    Firmware
    Format
    Size
    Date
    Add to My Documents
    171CCC9x0x0 Momentum M1E 984LL Exec. (Version V1.30)
    Files in document
    bin
    192 KB
    zip
    299.2 KB
    bin
    488 KB
    bin
    488 KB
    bin
    488 KB
    bin
    488 KB
    bin
    488 KB
    bin
    192 KB
    bin
    488 KB
    bin
    488 KB
    bin
    488 KB
    bin
    488 KB
    Description
    This 984LL firmware can be installed on any of the following Momentum PLCs:171CCC96020 (984LL only)171CCC98020 (984LL only)171CCC96030 (IEC or 984LL)171CCC98030 (IEC or 984LL)
    prp.document.label.format zip
    Size 5 MB
    Date 25/2/15
    Files in document
    bin
    192 KB
    zip
    299.2 KB
    bin
    488 KB
    bin
    488 KB
    bin
    488 KB
    bin
    488 KB
    bin
    488 KB
    bin
    192 KB
    bin
    488 KB
    bin
    488 KB
    bin
    488 KB
    bin
    488 KB
    Description
    This 984LL firmware can be installed on any of the following Momentum PLCs:171CCC96020 (984LL only)171CCC98020 (984LL only)171CCC96030 (IEC or 984LL)171CCC98030 (IEC or 984LL)
    171CCC98020 Momentum M1E 984LL Exec. v.1.30 (8/09) (Version V1.30)
    Files in document
    bin
    488 KB
    bin
    488 KB
    bin
    488 KB
    bin
    488 KB
    bin
    488 KB
    bin
    488 KB
    bin
    488 KB
    zip
    299.2 KB
    bin
    488 KB
    bin
    488 KB
    Description
    Exec. v.1.30 (m1ev130.bin)Reference Resolution #199702File M1ev130.zip contains: A document that explains the enhancement features, files for Proworx NXT and Proworx32, and the firmware (bin file).1) Enhancement: A modification was made to the 984LL Exec version 1.30 that allows users to control the retransmission timer and TCP socket time-out when performing MSTR Read multiple registers and Write multiple register operations. Exec. v.1.28 (m1ev128.bin)Reference Resolution #1905581) Fixes a problem in the web page where the TCP Retry counter would increment every time an MSTR Function Block was activated.2) The PSH flag is no longer set in the SYN or FIN.3) Now responds to a second ARP request.4) If 2 or more MSTRs are programmed in logic, any one of the MSTRs may stop operating for up to 5 minutes before recovering.Exec. v.1.26 (m1ev126.bin)In the 984LL Exec v.1.25, a modification was made to the IO Bus Generic IO Map to change the behavior of Advantys Island operation in the event of an IO point fault. The 984LL Exec v.1.26 removes the changes made to the Exec in v.1.25 so that applications currently using the Generic IO Bus map will be compatible with the latest Execs. This modification for Advantys Island operation on the M1E IO Bus is now accomplished by importing new M1-Advantys mdc files to Concept.Exec. v.1.25 (m1ev125.bin)Reference Resolution #1746431) Resolves an issue where the M1E would not respond to ICMP ping commands when communicating through routers across a WAN.
    prp.document.label.format zip
    Size 4.6 MB
    Date 6/7/04
    Files in document
    bin
    488 KB
    bin
    488 KB
    bin
    488 KB
    bin
    488 KB
    bin
    488 KB
    bin
    488 KB
    bin
    488 KB
    zip
    299.2 KB
    bin
    488 KB
    bin
    488 KB
    Description
    Exec. v.1.30 (m1ev130.bin)Reference Resolution #199702File M1ev130.zip contains: A document that explains the enhancement features, files for Proworx NXT and Proworx32, and the firmware (bin file).1) Enhancement: A modification was made to the 984LL Exec version 1.30 that allows users to control the retransmission timer and TCP socket time-out when performing MSTR Read multiple registers and Write multiple register operations. Exec. v.1.28 (m1ev128.bin)Reference Resolution #1905581) Fixes a problem in the web page where the TCP Retry counter would increment every time an MSTR Function Block was activated.2) The PSH flag is no longer set in the SYN or FIN.3) Now responds to a second ARP request.4) If 2 or more MSTRs are programmed in logic, any one of the MSTRs may stop operating for up to 5 minutes before recovering.Exec. v.1.26 (m1ev126.bin)In the 984LL Exec v.1.25, a modification was made to the IO Bus Generic IO Map to change the behavior of Advantys Island operation in the event of an IO point fault. The 984LL Exec v.1.26 removes the changes made to the Exec in v.1.25 so that applications currently using the Generic IO Bus map will be compatible with the latest Execs. This modification for Advantys Island operation on the M1E IO Bus is now accomplished by importing new M1-Advantys mdc files to Concept.Exec. v.1.25 (m1ev125.bin)Reference Resolution #1746431) Resolves an issue where the M1E would not respond to ICMP ping commands when communicating through routers across a WAN.
  • Technical FAQs

    No results found.
    Unfortunately, related FAQs are unavailable due to temporary technical issues. Please try again later.